Instruction Manual

36 AFTER SALES SUPPORT 0345 605 2067
TECHNICAL DATA
The sound values have been determined according to noise test code given in EN 50636-2-91,
using the basic standards EN ISO 11201 and EN ISO 3744.
The sound intensity level for the operator may exceed 80dB(A) and ear protection measures are
necessary.
The declared vibration value has been measured in accordance with a standard test method
(according to EN 50636-2-91) and may be used for comparing one product with another. The
declared vibration value may also be used in a preliminary assessment of exposure.
WARNING! Depending on the actual use of the product the vibration values can differ from the
declared total! Adopt proper measures to protect yourself against vibration exposures! Take the
whole work process including times the product is running under no load or switched off into
consideration!
Proper measures include among others regular maintenance and care of the product and cutting
attachments, keeping hands warm, periodical breaks and proper planning of work processes!
Measured sound pressure level LpA: 79dB(A), K=3dB(A)
Measured sound power level LwA: 90dB(A), K=3dB(A)
Guaranteed sound power level LwA: 94dB(A)