HTSD10X 10X Pan-Tilt Speed Dome Camera 200 New Highway, Amityville, NY www.specotech.
CONTENTS Warning & Caution 3 What’s in the Box? 3 General Features Names of Each Part 4 5 Installation A. Connection Methods B. Ceiling Mount Type 6 7 C. Embedded Mount Type Quick Operating Keys Diagnostic 8 9 OSD Menu Setting A. OSD Menu Table 10 B. DOME SET 11 C. CAMERA SET 16 D. PRESET 18 E. AUTO SCAN 19 F. TOUR SET 20 G. PRIVACY SET 21 H. PATTERN SET 22 I. ALARM SET 23 J. SECTOR SET 24 DIP Switch Setting A. ID Setting (DIP SW1) B.
WARNING & CAUTION If you fail to read this information and handle the product incorrectly, serious injury may occur. Never install the product in area exposed to oil or gas. This symbol is intended to alert the user to the presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. Never install the product on a ceiling that cannot hold its weight.
GENERAL FEATURES 100X Zoom Mini Speed Dome Quick Operation Keys 10X Optical Zoom with 10X digital zoom This camera provides quick functional keys in order to be easily controlled by any controller or DVR. ±0.02° dome system accuracy With 0.
NA MES OF EA CH PA RT 1. Surface Mount Adaptor 2. Cap Screw ( PT3/4 , 2EA ) 3. Dip Switch 4. Terminal Block 5.
INSTALLATION A. CONNECTION METHOD A-1 1. 2. 3. 4. 5. 6. Loosen the screws on the domes cover and remove it from the base. (Screws will not come out) Loosen the screws which connect the mount cover and Main base and separate the dome cover from the main base. (Screws will not come out) Connect power (12 VDC 1.5 A ) to Power and GND. Connect video to Video and GND. Connect communication cable to RS-485 connectors. Connect alarm cable to GND like 1 and GND, 2 and GND, 3 and GND, 4 and GND.
INSTALLATION B. MOUNT 1. Attach the surface mount adaptor with 4 screws at the installation site. (FIG.4) 2. When you use pipe, please note the standard size of pipe. (FIG.5) 3. Re-assemble the domes.
QUICK OPERATING KEYS 1-64 + preset and 101~200 + preset are used for preset and 65-100 + preset used f or functions. For example, to enter OSD MENU, press the button 95 +PRESET.
QUICK OPERATING KEYS DIAGNOSTIC When the Power is turned on a DIAGONOSTIC is operated. The following messages are displayed on the monitor. CAMERA ID : 001 BAUD RATE : 2400 BPS WAITING……… A. PAN ORIGIN CHECK OK TILT ORIGIN CHECK OK TX CONNECTION TEST OK CAMERA COMM TEST OK Pan Origin Test Zero point of Pan is founded after Panning test. B. Tilt Origin Test Zero point of Tilt is founded after Tilting test. C.
EXIT SECTOR ALARM PATTERN PRAVACY TOUR AUTO SCAN CAMERA SET DOME SETUP MAIN MENU ALARM SET : 03 : TOUR01□□□□□□ : 01 : 01 : 10 : 200°/S TOUR TITLE TOUR STEP PRESET NO DWELL TIME SPEED EXIT EXIT SAVE ALARM ACT ALARM INPUT ALARM NO. : SECTOR01□□□ : 01 SECTOR SET [PATTERN CLEAR] [LOAD OPTIMIZED DEFAULT UPGRADED DATE: 06.28,06 CAMERA MODULE: SDM100 [PREVIOUS PAGE] COORDINATE:ON/OFF [PREVIOUS PAGE] [PRIVACY CLEAR] [SECTOR CLEAR] [PRESET CLEAR] [PREVIOUS PAGE] FIRMWARE VER.:2.
OSD MENU SETTING To enter the OSD Menu, press the button 95 + PRESET. MAIN MENU DOME SETUP CAMERA SET AUTO SCAN TOUR PRAVACY PATTERN ALARM SECTOR EXIT * Use the joystick “up - down” to move the position and “left - right” to make selection B. Dome Setup To enter the Dome setup, move the joystick right to move the cursor. DOME SET B-1.
OSD MENU SETTING B-2. DOME SET - RECOVER This feature allows the dome to work from the last setting before you use the dome manually (Auto scan, group tour, pattern or sectors) , after the set time, even power shut down and it turns on again. Recovery time can be programmed from 15 second to 90 seconds. The default setting is OFF. B-3. DOME SET - MANUAL SPEED Manual Speed of Pan/Tilt is selectable from 10°/sec up to 200°/sec. The default setting is 100°/sec B-4.
correct password. In order to enter [PASSWORD] page, system lock status is must set as ON. OSDMove MENU joystick toSETTING right or left direction to select ON. The default setting is OFF. B-8-2. DOME SET – [NEXT PAGE] – [PASSWORD] To enter this page to set a password, move the joystick to the right direction. The password must be set by preset number from 001 to 255 (Default 99) A. OSD MAIN MENU TABLE (PAGE 11) The default setting is BLANK.
OFF/ON when the cursor is located each item. OSD MENU SETTING OSD DISPLAY CAMERA ID : PRESET ID : SECTOR ID : COORDINATE : [PREVIOUS PAGE] OFF OFF OFF ON DEFAULT SETTING B-8-4. DOME SET – [NEXT PAGE] – [SYSTEM STATUS] This page shows the information of this camera. SYSTEM STATUS PROTOCOL : BAUD RATE : FIRMWARE VER. : UPGRADED DATE : CAMERA MODULE : [PREVIOUS PAGE] PELCO D, P 2400 BPS 2.00 06.
OSD MENU SETTING - To clear memorized data, move joystick to the right direction when cursor is on each item. TOUR CLEAR TOUR CLEAR ARE YOU SURE? YES NO Press FOCUS NEAR button when the cursor is at YES in order to clear memorized data. Then each item such as tour, preset, sector and so on is displayed on the monitor about 2~3 seconds. After this process, the menu is returned to the previous page. * [PRESET CLEAR], [SECTOR CLEAR], [PRIVACY CLEAR], [PATTERN CLEAR] are same as [TOUR CLEAR].
OSD MENU SETTING C. CAMERA SET CAMERA SET FLICKER MIRROR APERTURE D ZOOM WB MODE PIC FLIP BLC D/N MODE DSS MODE EXIT : : : : : : : : : OFF OFF 10 OFF AWB MODE OFF OFF AUTO OFF C-1. CAMERA SET - FLICKERLESS Flickerless feature is selected between 50Hz and 60Hz. The default setting is OFF (NTSC: 60Hz / PAL: 50Hz). Set flicker mode ON when power source is in discord with frequency. The default setting is OFF C-2. CAMERA SET - MIRROR This feature creates a mirror image. The default setting is OFF. C-3.
AWB Mode – 3,200°K to 6, 000°K OSD MENU SETTING l Indoor – up to 3,200°K l Outdoor – up to 5,800°K l ATW Mode - 2,000°K to 10, 000°K C-6. CAMERA SET – PIC FLIP Picture flip feature turns ths picture upside down. Move the joystick to the right or left direction to select OFF/ON. The default setting is OFF. C-7. CAMERA SET – BLC (Back Light Compensation) The default setting is OFF and BLC modes can be OFF/ON. OFF – Backlight compensation is not activated. ON – Back light compensation is activated.
OSD MENU SETTING D. PRESET SET To enter PRESET SET, move the joystick to the right direction. PRESET SET PRESET NO :001 PRESET ID :PRESET001------PAN :XXX.XX TILT : XXX.XX SAVE EXIT D-1. DEFAULT SETTING PRESET – PRESET NO. Up to 164 numbers of preset positions are available. Move joystick to the right or left direction to select a preset no. D-2. PRESET – PRESET ID To set preset ID, select up to 16 characters using Joystick to the left or right.
OSD MENU SETTING E. AUTO SCAN SET * 66 + preset button is working as AUTO SCAN after setting. AUTO SCAN SET START ANGLE END ANGLE DIRECTION ENDLES SPEED : : : : : XXX.X.XX.X XXX.X.XX.X CW OFF 10°/S DWELL TIME SAVE AND EXIT EXIT : 03 DEFAULT SETTING E-1. AUTO SCAN – START ANGLE To set the start angle, press FOCUS FAR button then move the joystick to the starting angle which is to be memorized. Press FOCUS FAR button again is to escape. E-2.
E-8. AUTO SCAN – EXIT OSD MENU SETTING To escape this page, move the joystick to the right . F. TOUR SET 8 Programmable tours can be set and each tour is available to set up to 64 preset steps. After setting the data to each tour group, 71~78 + preset buttons are working as group tour # 1~8 TOUR SET TOUR NO TOUR TITLE TOUR STEP PRESET NO. DWELL TIME SPEED : : : : : : 01 TOUR01□□□□□□□□□□ 01 01 03 200°/S DEFAULT SETTING SAVE EXIT F-1. TOUR SET – TOUR NO. Max. 8 group tour no.
F-8. TOUR SET – EXIT OSD SETTING To escapeMENU this page, move the joystick to the right G. PRIVACY SET 4 Privacy masking zones are available to block out areas of the scene. PRIVACY SET PRIVACY NOMBER : 01 DISPLAY : OFF ACTION : MOVE SAVE EXIT DEFAULT SETTING G-1. PRIVACY SET – PRIVACY NUMBER. Up to 4 privacy masking zones are available. G-2. PRIVACY SET – DISPLAY. Move joystick to the right or left direction to set ON in order to show the selectable block in the center of the monitor.
G-5. PRIVACY SET –EXIT To escape this page, move the joystick to the right OSD MENU SETTING H. PATTERN SET 8 programmable patterns are available with 16 characters of title. After setting the data to each pattern # 1~8, 81~88+ preset buttons are working as Pattern # 1~8. PATTERN SET PATT NO : 01 PATT TITLE: PATTERN01□□□□□□□ DATA FILL : 0% SAVE EXIT DEFAULT SETTING H-1. PATTERN SET –PATT NO. Up to 8 programmable user-defined patterns set by the joystick are available. H-2.
OSD MENU SETTING I. ALARM SET 4 Alarm inputs are available and each alarm can activate presets, group tours or patterns. ALARM SET ALARM NO : 01 ALARM INPUT: OFF ALARM ACT : 001 SAVE EXIT DEFAULT SETTING I-1. ALARM SET – ALARM NO. Up to 4 alarms are selectable by using the joystick to the right when the cursor is on ALARM NO. I-2. ALARM SET – ALARM INPUT Input alarm provides two different ways - NC (Normal Close) or NO (Normal Close) I-3.
OSD MENU SETTING J. SECTOR SET Up to 8 programmable sectors are available with 16 characters. This feature is useful to memorize certain locations such as a parking zone, etc. When a camera goes through this area, it shows the letter you memorized. SECTOR SET SECTOR SECTOR SECTOR SECTOR SAVE EXIT Start Position NO : 01 ID: SECTOR01□□□□□□□□ START: XXX.X.XX.X END : XXX.X.XX.X End Position DEFAULT SETTING J-1. SECTOR SET – SECTOR NO. Up to 8 programmable sectors set by the joystick are available. J-2.
K. EXIT To escape the OSD Main Menu, move the joystick to the right or left direction then this DIP camera SWITCH is readySETTING to operate. A-1. DIP SW SETTING st th This Speed Dome camera provides up to 63 camera ID’s, adjustable using the 1 ~6 Dip switch. Open the camera case to set ID using DIP SW1. * Factory default: Camera ID = 1, PELCO-D Termination Baud rate Protocol ID Set A-2.
DIP SWITCH SETTING A-3. PROTOCOL th th 7 ~8 dip switches are used for Protocol Setting. Factory Default: Pelco-D or Pelco-P ( Auto detection) DIP SW 1- 7 DIP SW 1- 8 OFF OFF Pelco-D or Pelco-P A-4. BAUD RATE SETTING th The 9 Dip Switch is used for BAUD RATE setting. DIP SW can be changeable to 2400bps, 9600bps. Factory Default: 2400bps. DIP SW 1 9 th BAUD RATE OFF 2400 ON 9600 . A-5. 485 TERMINATIONS 10 th Dip Switch is used for 100Ω termination.
TROUBLE SHOOTING If you have trouble operating in your camera, refer to the following. PROBLEM SOLUTION Not operating Check if the power supply is 12 VDC. Check if RS-485 communication cable is connected correctly. Check camera ID setting. Check the termination. No picture Check if all the cables are connected correctly. Check if the monitor is adjusted correctly. Check if video signal line is cut. Dark screen Adjust the monitor.
SPECIFICATIONS MODEL PAN /TILT HTSD10X Pan Rotation Angle Manual Pan Speed Preset Tilt Rotation Angle Manual Tilt Speed Preset System Accuracy Presets Group Tour FUNCTIONS POW ER OTHERS CAMERA MODULE Auto scan Pattern Privacy Zone Sector Password Protection Alarm Input Alarm Actions Auto Flip OSD Menu Communication Protocol Power Consumption Power Supply Construction Dimensions W eight Motor Type Micro Steps Storage Temperature Operating Temperature Certifications Image Sensor Total NTSC Image PAL
NTSC PAL W HITE BALANCE Flickerless DIMENSIONS ON / OFF (1/100) ON / OFF (1/120) AW B/ATW/INDOOR/ OUTDOOR 29