SPECO TECHNOLOGIES KEYBOARD CONTROLLER KBD-927 Instruction Manual L Please read this manual thoroughly before use and keep it handy for future reference. Rev.
WARNING AND CAUTION WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR OTHER OPENINGS ON THE EQUIPMENT.
FCC COMPLIANCE STATEMENT FCC INFORMATION: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT.
IMPORTANT SAFEGUARDS 1. READ INSTRUCTIONS -- All the safety and operating instructions should be read before the appliance is operated. 2. RETAIN INSTRUCTIONS -- The safety and operating instructions should be retained for future reference. 3. CLEANING -- Unplug video monitor or equipment from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 4.
Table of Contents Chapter 1.0 INTRODUCTION 1.1 Features 1.2 Unpacking Chapter 2.0 INSTALLATION 2.1 Connection Diagram 2.2 Dip Switch Setting 2.3 Keyboard Setup 2.4 Install with ADR series 2.5 Install with SDR series 2.6 Install with IDR series Chapter 3.0 OPERATION 3.1 Multiplexer Control 3.2 Keyboard Lock/Unlock 3.
Chapter 1 INTRODUCITON 1.1 Features This keyboard controller is capable to control 32 FastraxII dome cameras and remote control functions for variety of external switching devices like Multiplexer(max 255), Digital Video Recorder(max 99) etc… The keyboard controller features: • The capability of control a camera’s panning and tilting movement with variable speed from 0.5 °/sec to 90°/sec as well as its zoom, focus, and iris command. Normal speed is inversely proportional to the current zoom ratio.
1.2 Unpacking Unpack the equipment and make sure all listed items are included in the box.
Chapter 2 INSTALLATION 2.1 Connection Diagram 2.1.
2.1.2 Single Multiplexer POWER AC 24V POWER AC 24V POWER AC 24V AC+ GND AC- (RX-) RX-(TX-) AL2 GND GND AL7 AL3 AL8 AL4 GND GND COM1 COM3 NC1 NC3 NO3 NO1 COM4 COM2 RX-(TX-) (RX-) RX+(TX+) NC2 NO2 RS-485 (RX+) (RS-422) SPOT MONITOR MAIN MONITOR BNC BNC MULTIPLEXER RS-485(+) PIN No.4 RS-485(-) PIN No.
2.1.3 Single User with Two Multiplexer POWER AC 24V POWER AC 24V POWER AC 24V AC+ GND AC- RX-(TX-) (RX-) (RX+) RX+(TX+) AC- AL2 GND GND AL3 AL7 AL8 AL4 GND GND COM1 COM3 NC1 NC3 NO3 NO1 COM4 COM2 RX-(TX-) (RX-) NO2 RS-485 RX+(TX+) NC2 (RX+) NO4 (RS-422) NC4 AC+ AL1 AL6 BNC AL5 FGND AWG # 24 1ST MAIN MONITOR SPOT MONITOR 2ND MAIN MONITOR BNC BNC BNC 1ST MULTIPLEXER 2ND MULTIPLEXER RS-485(+) PIN No.4 RS-485(-) PIN No.
2.1.4 Two Multiplexer with Slave Keyboard Controller POWER AC 24V POWER AC 24V POWER AC 24V AC+ GND AC- (RX-) RX-(TX-) RX+(TX+) AC- (RX+) FGND AL1 AL6 AL2 GND GND AL3 AL7 AL8 AL4 GND GND COM1 COM3 NC1 NC3 NO1 NO3 COM4 COM2 (RX-) RX-(TX-) NO2 RS-485 RX+(TX+) NC2 (RX+) NO4 (RS-422) NC4 BNC AL5 AC+ AWG # 24 SPOT MONITOR FOR SLAVE K/B 1ST MAIN MONITOR SPOT MONITOR FOR MASTER K/B 2ND MAIN MONITOR BNC BNC BNC 1ST MULTIPLEXER 2ND MULTIPLEXER RS-485(+) PIN No.
2.2 Termination & Dip Switch Setting The first and last devices in an installation (dome and keyboard controller) must have the data line terminated by setting the DIP switch. Without proper termination, there is potential for control signal errors. Total length of the cable for communication should not exceed 1 mile. Refer to Figure 7 for setting the dome camera and keyboard controller termination.
Termination ON OFF DOME Multiplexer 1 ON OFF 2 ON OFF Subcontroll Controller er 3 4 5 6 ON SLAVE reserved OFF MASTER Table 1 - S1 Switch Setting 7 ON OFF 8 Factory Use 2.3 Multiplexer Control Duplex setup: NOTE: Multiplexers require a new ROM version to be controlled by the keyboard controller. The new multiplexer ROM accepts control instructions from the keyboard controller. If your multiplexer’s serial number is M104xxxx or higher, then it is ready to accept control instructions.
Unit address: Protocol: 001 ~ 128 B1 2.4 Keyboard Setup User need to setup network, passwords and special functions such as Uploading and Downloading programmed data from the dome cameras. To enter the Keyboard menu, press Ctrl + Menu. You will see the following menu. Joystick Up/Down scrolls menu items, push the stick to Right to enter the sub-menu. Configuration Network Data Bank Alarm Exit Configuration - Key Beep : ON - enable key beep sound, OFF - Disable beep sound.
- Com Ports Select the device to be connected on selected port.
FASTRAX-2L Vxxx Slave ID = 1 Input Password : xxxx CAM:000 ← Current Device ID = 1 ← Default setting is 9999 for administrator 1111 for user 3. Press Ctrl + Menu. Set the Slave ID to 01 4. Set Slave Node to “B” in case that master keyboard model is KBD-927(N : NTSC,P : PAL) Slave ID = 1 Slave Node : A/B ← A : KBD-927 RS485 Protocol Half duplex mode Tx-,Tx+ 2.
A. B. C. D. Switch the keyboard controller ON Input password (Factory setting is 9999) Open the menu of the keyboard controller by pressing Ctrl + Main Key. Set as below in Network menu. Set Baud Rate Dome : 9600 Mux : 9600 DVR485 : 9600 DVR232 : 9600 Com Port Dome : Dome Mux : None DVR485 : AUX IN DVR232 : ADR 4) How to setup ADR - Switch the ADR on. - Press the Menu button. Input password according to the instruction.
Select “Camera” on the Device menu. Unit ID should be 1 up to 99. Unit ID is not allowed number “0”. Set “PTZ Device” and “ID” of the dome camera. Select RS232/RS485 after PTZ is installed, and then set-up as below table.
RS232/RS485 Baud Rate Parity Data Stop Usage RS232 9600 None 8 1 Remote Control RS485 9600 None 8 1 PTZ Control 5) After setting Unit ID, Camera, and RS232/RS485, installing dome camera is basically completed. Please refer to the manual of ADR for the other installation. 6) Press the related number of the controller which is correspondent to unit ID of ADR.
D. Set as below in Network menu. Set Baud Rate Dome : 9600 Mux : 9600 DVR485 : 9600 DVR232 : 9600 Com Ports Dome : Dome Mux : None DVR485 : AUX IN DVR232 : SDR - 4) How to setup SDR Switch the SDR on. Press the Menu button. Input password according to the instruction. (Factory setting is 4321) If the below screen is appeared, set “Quick Setup” to “Off”. If press OK after putting Quick Setup to off status, the below screen will be appeared.
Select Camera of Device menu on the above menu. PTZ set up on the above Setup menu Select TEXT IN/PTZ after PTZ is installed, and then set-up as below RS232/TEXT IN Baud Rate Parity Data Stop Usage RS232 9600 None 8 1 Remote Control TEXT IN/PTZ 9600 None 8 1 PTZ Control 1) After installing Camera, and RS232 & TEXT IN/PTZ setup, the installation with dome camera is basically completed. Please refer to manual of SDR for the other installation.
2.7 Install with IDR series 22 AWG UTP CABLE WIRE CONNECTION DOME R(T)X+ R(T)X- JUNCTION BOX DOME1 + DOME1 - CONVERTER TX+(RS-485) TX-(RS-485) J-BOX(FRONT) JUNCTION BOX DOME2 + DOME2 - J-BOX(REAR) RS-232 CABLE IDR SERIES DATA2 DATA1 RS-232C to RS-485 CONVERTER Figure 11 – IDR Connection Diagram If user wants to connect with IDR, please proceed as the following order. 1) Connect RS-232C cable between RS-232C Port of IDR and DVR port of the J-box.
- Switch the IDR on. If press setup button on the above screen, the below screen will be appeared. Select camera input number that dome camera connected. Then install as below to select set-up PTZ after checking PTZ box. Port : COM2 RX Device : Fastrax….
If PTZ is not necessary for IDR, cable and installation here is not needed. (IDR is able to be controlled remotely and there’s no PTZ function) 8) How to IDR Remote setup - If selects Setup on main menu, the below screen will be appeared. After selecting System and checking Remote control box, please install as below to select Setup remote control. Device ID is not allowed number “0”.
Chapter 3 OPERATION 3.1 Keyboard Lock/Unlock (Hidden command) When the user leaves the control desk, he may wish to lock the keyboard controller to prevent unauthorized use. Pressing 777 + Enter will lock the keyboard controller. Pressing 777 + Enter while the keyboard is locked will open the password screen. If the correct password is entered, the keyboard controller will return to normal operation. If the power is turned OFF and ON while the keyboard is locked, it will ask for the password.
Select cameras 1 to 16 by pressing the camera number and then Main. The selected camera will appear in the full screen mode and is under control if it was dome camera. Even if no camera is connected to the multiplexer input, the screen will show the camera input (see following example). To select first multiplexer under control, press 1 + Mux ( m: ID of Mux – up to 128)successively Multiplexer 1 Keyboard controller 1 2 . . 15 16 1+ Main 2+ Main 15+ Main 16+ Main This sequence (No.
2) to the spot output of multiplexer 2 and the keyboard controller has control of the selected camera. 31+Cam = camera 15 of the second multiplexer. 3.
Key operation example Ctrl + Menu : Press and hold down Ctrl Key and press Menu Key 1 + Cam : Press 1 Key, Cam Key sequentially Ctrl + Joystick : Press and hold down Ctrl Key while manipulate Joystick Handle Enter + Joystick : Press and hold down Enter Key while manipulate Joystick Handle 3.3.1 Keys for Dome camera Function Key Label 1,2, ... 9,0 1,2, ...
Overrides auto focus. Moving the Zoom handle reactivates Auto Focus mode. Manual Focus Overrides auto iris. Moving the joystick reactivates Auto Iris mode. Manual Iris Zoom control. Zoom Joystick Twist Up / Down Left / Right Press(Toggle) Zoom control (proportional to position).(HID2404CZx model only). Tilt control, Cursor Up / Down in the PGM. menu Pan control, Cursor Left / Right or Page scroll in the PGM. Menu Pressing the joystick toggles between zoom control mode on and off.
3.3.3 Keys for DVR Function Key Label Descriptions DVR ID Selection. (e.g.:1 or 2+DVR). Id Selection Open a Pan/Tilt/Zoom screen which allows you to control properly configured cameras. PTZ Play recorded data / Pause playing. Play/Pause Rewind Play video backward at high speed. Pressing the button again toggles the playback speed Fast Forward Play video forward at high speed. Pressing the button again toggles the playback speed from During Playback mode returns the DVR to the Live Monitoring mode.
X times Forward play No.+ Shuttle ring CTRL+ENTR+ Joystick Jog dial CTRL+ENTR+Zoom of Joystick Fast rewind at x(1~8) times speed in IDR The Shuttle Ring only functions in the Playback mode. Turning the ring clockwise plays video forward. Turning the ring counterclockwise plays video backward. The Jog Dial only functions when playback video has been paused. By turning the jog dial clockwise, you can play video forward image-byimage.
Appendix A Trouble Shooting If problems occur, verify the installation of the camera with the instructions in this manual and with other operating equipment. Isolate the problem to the specific piece of equipment in the system and refer to the equipment manual for further information. Problem Possible Solution 1. Check that the dome camera IDs are set properly (See Figures 1 to 6). Check the polarity of the data line 1.
Appendix B SPECIFICATION Power Consumption 12VDC, 0.5W Control Method RS-485, RS-232C Baud Rates 2400~230K bps Operating Temperature 0°C to 50°C(32oF to 122oF) Humidity 0 to 90%RH(non-condensing) Storage temperature -20°C to 60°C(-40oF to 122oF) Dimension 380x168x70 Professional Joystick : 1.2k Weight Economic Joystick : 1.