VIEW ANGLE SETUP
VIEW ANGLE SETUP
PANNING RANGE
FLIP : 90
TILT LIMIT : OFF
SAVE AND EXIT(ESC TO CANCEL)
FLIP: OFF, AUTO, 90
, 100 , 110 , 120 ,
OFF: The dome camera moves until 90
vertically.
AUTO: When the camera reaches the floor directly above the moving object, it will stop. At
that time, release the Joystick instantly and pull it down again to run the auto-flip function.
When you use the panning range, it is recommended to use the flip mode to AUTO.
90
, 100 , 110 , 120 : Allows the image to flip digitally when the camera moves over the
setting angle vertically.
TILT LIMIT:
This option is designed to limit the view angle as there is some obstruction in zooming out
on specific areas of the tilt angle.
ON: When this option is enabled, the range of the tilt angle will be limited to 10 degree.
This can prevent obstruction or bad focusing problems caused by the horizontal line of the
semi sphere in the bubble.
OFF: When this option is disabled, the range of the tilt angle is not limited.
When you zoom out within the range of the tilt angle, you will see the horizontal line of the
semi sphere in the bubble. Focus issues may occur in certain lighting conditions.
PANNING RANGE
When the dome camera is installed near a wall, panning range can be limited by user.
PANNING RANGE SETUP
(CTRL KEY)
RIGHT LIMIT : 000.0
LEFT LIMIT : 000.0
ENABLE : OFF
SWAP : OFF
AUTO PAN : ON
SAVE AND EXIT(ESC TO CANCEL)
1. Place the dome camera under 90 degree vertically.
2. Set RIGHT LIMIT by pushing the Joystick to the right.
3. Set LEFT LIMIT by pushing the Joystick to the left.
4. Set ENABLE to ON to use.
To exchange the right and the left limit, set SWAP to ON.
To apply limits on the auto pan (endless panning), set AUTO PAN to ON.
NOTE: When the flip mode is 90
, 100 , 110 or 120 and you moves over 90 vertically,
the panning range operates in opposite side.