Technical Manual
Table Of Contents
- ATLAS® 4500 Multimode Station
- Introduction
- Product Overview
- Installation and Configuration
- Alignment
- Maintenance
- Technical Support and Service
- 700/800 MHz Circuit Descriptions
A-12 ATLAS 4500 Multimode Station Technical Manual July 2016
Controller Board Appendix A - 700/800 MHz Circuit Descriptions
• RX Interface
• DSP Interface
• Fan Control
• External Port and Serial Links
• Auxiliary
•Firmware
A.4.1 General Description
The Controller PCB contains the following:
• The main microcontroller IC1 containing CPU, flash, RAM, UARTs, ports etc
•Data latches
• Serial Flash
• 3.3-V and 5-V linear regulators
• Power on reset IC
•PA I/F, etc
• Control /noise filter for the fan in the PA
• 10 MHz osc det I/P used for 10 MHz ref switch control in the Exciter
• DSP I/F port
• Exciter I/F port
• Receiver I/F port
•Relay O/P
• LED I/F
• Configuration links
A.4.2 Schematic Description
A.4.2.1 PA Interface
The interface has 14 pins. The PA interface provides 24 V 450 mA and 5 V 10 mA.
It controls the PA by means of the PTT line and the bias line [nominally 4 V at
77°F (25°C)].
The forward power and reverse power detector voltages are transferred to the
controller. The PA copper plate temperature can be read through a single pulse
width modulation line.
During power up, the Controller loads the PA calibration data from the Serial flash
IC on the I2C bus. This bus is also used for initial PA calibration.