Product Manual

English
16
Product Storage Spectra Precision recommends you observe the following
rules for long-term storage (2-3 months). These rules are
dictated by the presence of two non-removable Li-Ion
batteries inside the MobileMapper 300.
Always charge batteries before long-term storage
Storage room should be ideally at 5°C (41°F) ambient
temperature to minimize irreversible capacity loss.
Always charge batteries after long-term storage.
Power/Data
Connector Pinout
Connector socket type: Hirose HR30-6R-6P
Seen from outside the MobileMapper 300:
Reset Procedure A reset procedure may be required in some situations where
the MobileMapper 300 does not operate as expected. No user
data will be lost through this procedure. To trigger a reset
sequence:
Hold the Power button depressed for 12 seconds. Note
that after two seconds of depressing this button, the
MobileMapper 300 will be turned off or on, depending on
the power status when you started pressing the button.
Please ignore this indication and just keep on pressing the
Power button for the required 12 seconds (starting from
the moment you depressed the button).
After the 12 seconds have elapsed, release the Power
button. The Power/Charging LED starts blinking red and
green, as it would do on a normal start-up, but this time
for about 25 seconds.
At the end of the reset sequence, the MobileMapper 300
will stay powered and the Power/Charging LED will turn
solid green.
Pin Signal
1 Ground (power)
2 DC Power In (9-16 V)
3Rx (In)
4 Tx (out)
5 Ground (data)
6 Not connected
1
2
3
4
6
5