NOTE: If you are using the second setup, you will need to
use the V-cable from the cable kit P/N 91865-00 which
connects to your computer’s DB9 serial connector. In this
case, you will not need to use the DB9-to-USB extension
cable.
• Turn on MobileMapper 300 and wait until the Power/
Charging LED turns solid green (meaning MobileMapper
300 is ready).
• Launch Spectra Precision loader on the computer.
• Browse to the *.bin file provided by Spectra Precision.
•In the Spectra Precision loader window, choose the COM
port used to communicate with MobileMapper 300.
If you are using Bluetooth, pair the MobileMapper 300
with your computer using Bluetooth Manager on your
computer, and then select the Serial Port profile. A virtual
COM port number will be returned that you should specify
in Spectra Precision Loader.
You may be asked to enter the password “1234” to secure
the wireless connection with MobileMapper 300. (Every
MobileMapper 300 is factory-set with their internal
Bluetooth module PIN code set to“1234”.)
• Click Start in the Spectra Precision loader window. This
starts the upgrade phase. Wait about 20 to 30 minutes
until a message is returned in the Spectra Precision loader
window indicating the end of the upgrade.
CAUTION: While the MobileMapper 300 is being
upgraded, the indications provided by two LEDs on the
MobileMapper 300 should be ignored. Only Spectra
Precision loader reports accurate information on the
operation in progress.
•Close the Spectra Precision loader window and disconnect
the MobileMapper 300 from the computer and the
external power source. It is now ready for use.