Product Manual

Automatic Spot Match (only DG813) - Automatic-Spot-Match can be used
for measuring an unknown grade value in an existing pipe or open trench.
Press and release the M button at the standard display and select Spot Match
using the (+)/(-) and left/right buttons.
Press/release button M escape/return to the standard display.
Pressing and releasing E button starts the automatic Spot Match while the beam
becomes a rotating fan beam which will be automatically aligned to the SF803‘s center position.
Note: The left SF along with a grade symbol flashes while an additional SF symbol at the right
site of the display indicates the beam movement until the beam is centered. When Spot Match
has finished, the beam goes through the SF hole and the measured grade value will be displayed.
Automatic Spot Match can be exited any time by pressing and releasing ESC button.
Automatic SpotLok (only DG813) - Automatic SpotLok (like PlaneLok) can be used to align
and hold the beam automatically to the SF803’s center point in automatic or manual mode.
Press and release the M button at the standard display and select SpotLok using
the (+)/(-) and left/right buttons.
Press/release button M escape/return to the standard display.
Pressing and releasing E button starts automatic SpotLok while the beam becomes a rotating
fan beam which will be automatically aligned to the SF803‘s center position.
Note: The left SF along with a lock symbol flashes while an additional SF symbol at the right site
of the display indicates the beam movement until the beam is centered.
Automatic SpotLok can be exited any time by pressing and releasing ESC button where the unit
switches back to automatic or manual mode.
23
Z
%
%?