Manual
1 (3+3 ppm × D) mm –20 °C to –10 °C, +40 °C to +50 °C (–4 °F to +14 °F, +104 °F to +122 °F).
2 Standard deviation based on ISO 17123-4
3 Measuring time may vary depending on measuring distance and conditions. For the initial measurement, it may take a few more seconds.
4 Battery life specification at 25 °C (77 °F). Operation time may be shorter in low temperatures and if the battery is not new.
5 Good conditions (good visibility, overcast, twilight, underground, low ambient light).
6 Normal conditions (normal visibility, object in the shadow, moderate ambient light).
7 Difficult conditions (haze, object in direct sunlight, high ambient light).
SpecificationS nivo 1.c / nivo 2.c nivo 3.c / nivo 5.c
ANGLE MEASUREMENT NIVO 1.C NIVO 2.C NIVO 3.C NIVO 5.C
Minimum increment Degree:
Gon:
0.5"
0.1 mgon
1"/0.3 mgon
1"
0.1 mgon
2"/0.6 mgon
Degree:
Gon:
1"
0.1 mgon
3"/1 mgon
1"
0.1 mgon
5"/1.5 mgon
ISO 17123-3 accuracy (horizontal and vertical)
TELESCOPE
30× (18x/36x with optional eyepieces)
40 mm (1.6 in)
1.5 m (4.9 ft)
Yes, 3 levels
Yes
30× (18x/36x with optional eyepieces)
45 mm (1.8 in)
1.5 m (4.9 ft)
Yes, 3 levels
Yes
Magnication
Eective diameter of objective
Minimum focusing distance
Reticle illumination
Lumiguide
DISTANCE MEASUREMENT Good
5
Normal
6
Dicult
7
Good
5
Normal
6
Dicult
7
Reectorless mode (KGC 18%)
Reectorless mode (KGC 90%)
350 m (1,148 ft)
500 m (1.640 ft)
250 m (820 ft)
400 m (1,312 ft)
200 m (656 ft)
250 m (820 ft)
280 m (920 ft)
500 m (1,640 ft)
250 m (820 ft)
500 m (1,640 ft)
200 m (656 ft)
300 m (984 ft)
With single prism (Good conditions) 3,000 m (9,843 ft) 5,000 m (16,404 ft)
Accuracy (Prism/Precise mode) 1, 2 (2+2 ppm × D) mm (2+2 ppm x D) mm
Accuracy (Reectorless/Precise mode)1, 2 (3+2 ppm x D) mm (3+2 ppm x D) mm
MEASURING INTERVAL
3
Prism mode Precise mode
1.6 sec. 1.5 sec.
Normal mode
0.8 sec. 0.8 sec.
Reectorless mode
Precise mode
2.1 sec. 1.8 sec.
Normal mode
1.2 sec. 1.0 sec.
Least count
Precise mode
1 mm (0.002 ft) 1 mm (0.002 ft)
Normal mode
10 mm (0.02 ft) 10 mm (0.02 ft)
ENVIRONMENTAL SPECIFICATIONS
OPERATING TEMPERATURE RANGE –20 °C to +50 °C (–4 °F to +122 °F) –20 °C to +50 °C (–4 °F to +122 °F)
ATMOSPHERIC CORRECTION
Temperature range –40 °C to +60 °C (–40 °F to +140 °F) –40 °C to +60 °C (–40 °F to +140 °F)
Barometric pressure 400 mmHg to 999 mmHg
533 hPa to 1,332 hPa
15.8 inHg to 39.3 inHg
400 mmHg to 999 mmHg
533 hPa to 1,332 hPa
15.8 inHg to 39.3 inHg
TILT SENSOR Dual axis Dual axis
LEVEL VIALS
Sensitivity of Circular level vial 10'/2 mm 10'/2 mm
OPTICAL PLUMMET Magnication 3× 3×
DISPLAY
Face 1
Face 2
QVGA,16 bit color, TFT LCD, backlit (320x240 pixel)
Backlit, graphic LCD (128x64 pixel)
QVGA,16 bit color, TFT LCD, backlit (320x240 pixel)
Backlit, graphic LCD (128x64 pixel)
MEMORY 128 MB RAM, 128 MB Flash memory 128 MB RAM, 128 MB Flash memory
DIMENSIONS W X D X H 149 mm x 145 mm x 306 mm
(5.8 in x 5.7 in x 12.0 in)
149 mm x 145 mm x 306 mm
(5.8 in x 5.7 in x 12.0 in)
WEIGHT APPROX.
Main unit (without batteries) 3.9 kg (8.6 lb) 3.8 kg (8.4 lb)
Battery 0.1 kg (0.02 lb) 0.1 kg (0.02 lb)
Carrying case 2.3 kg (5.1 lb) 2.3 kg (5.1 lb)
INTERNAL LIION BATTERY X2
Operating time4 approx. 12 hours (continuous distance/angle measurement) approx. 7.5 hours (continuous distance/angle measurement))
approx. 26 hours
(distance/angle measurement every 30 seconds)
approx. 16 hours
(distance/angle measurement every 30 seconds)
approx. 28 hours (continuous angle measurement) approx. 20 hours (continuous angle measurement)
Output voltage 3.8 V DC 3.8 V DC
Recharging time 4 hours 4 hours
COMMUNICATION PORTS 1 x serial (RS-232C), 2 x USB (host and client) 1 x serial (RS-232C), 2 x USB (host and client)
WIRELESS COMMUNICATIONS Integrated Bluetooth Integrated Bluetooth
Nivo C Series
4
NikoN Products