Owner manual

Distance measurement
Range with Nikon specied prisms
(Good conditions
2
)
- With reector sheet (5 cm x 5 cm):
Nivo 1.C, Nivo 2.C: 1.5 m to 270 m
Nivo 3.C, Nivo 5.C: 1.5 m to 300 m
- With single prism 6.25 cm Nivo 1.C,
Nivo 2.C: 1.5 m to 3,000 m Nivo 3.C,
Nivo 5.C: 1.5 m to 5,000 m
Range reectorless mode
1
- Nivo 1.C, Nivo 2.C
KGC (18%)
1
Good
2
: 350 m (1,148 feet)
Normal
3
: 350 m (1,148 feet)
Difcult
4
: 200 m (650 feet)
KGC (90%)
1
Good
2
: 500 m (1,640 feet)
Normal
3
: 400 m (1,312 feet)
Difcult
4
: 250 m (820 feet)
- Nivo 3.C, Nivo 5.
KGC (18%)
1
Good
2
: 280 m (820 feet)
Normal
3
: 250 m (820 feet)
Difcult
4
: 200 m (650 feet)
KGC (90%)
1
Good
2
: 500 m (1,640 feet)
Normal
3
: 500 m (1,640 feet)
Difcult
4
: 300 m (984 feet)
- Shortest possible range: 1.5 m
(4 feet 11 116 inches)
Accuracy
5
(Precise mode) ISO 17123-4
- Prism: ±(2+2 ppm × D) mm
- Reectorless: (3+2 ppm × D) mm
Measuring interval
6
- Nivo 1.C, Nivo 2.C
Prism mode
Precise mode: 1.6 s
Normal mode: 0.8 s
Reectorless mode
7
Precise mode: 2.1 s
Normal mode: 1.2 s
- Nivo 3.C, Nivo 5.C
Prism mode
Precise mode: 1.5 s
Normal mode: 0.8 s
Reectorless mode
7
Precise mode: 1.8 s
Normal mode: 1.0 s
- Least count: 1 mm 10 mm
Angle Measurement
ISO 17123-3 Accuracy (horizontal and
vertical): 1/0.3 mgon Nivo 1.C 2”/0.6 mgon
Nivo 2.C; 3”/1 mgon Nivo 3.C; 5/1.5 mgon
Nivo 5.C
Reading system: Absolute encoder
Circle diameter: 62 mm (2.4 in)
Horizontal/Vertical angle: Diametrical
Minimum increment
- Nivo 1.C: Degree: 0.5”; Gon: 0.1 mgon
- Nivo 2.C, Nivo 3.C, Nivo 5.C: Degree: 1;
Gon: 0.1 mgon
Telescope
Tube length: 125 mm (4.9 in)
Image: Erect
Magnication: 30×
(18x/36x with optional eyepieces)
Effective diameter of objective:
- Nivo 1.C, Nivo 2.C: 40 mm (1.6 in)
- Nivo 3.C, Nivo 5.C: 45 mm (1.7 in)
EDM diameter:
- Nivo 1.C, Nivo 2.C: 45 mm (1.7 in)
- Nivo 3.C, Nivo 5.C: 50 mm (1.9 in)
Field of view: 1°20’
Resolving power: 3”
Minimum focusing distance: 1.5 m
(4 feet 11 116 inches)
Laser Pointer: Coaxial Red Light
General Specications
Level vials
- Sensitivity of circular level vial: 10/2 mm
Optical plummet
- Image: Erect
- Magnication:
- Field of view: 5°
- Focusing range: 0.5 m to ∞
Display:
- Left display face: QVGA, 16 bit color, TFT
LCD, backlit (320x240 pixel)
- Right display face: Backlit, graphic LCD
(128x64 pixel)
Laser plummet (optional): 4 levels
Memory: 128 MB RAM, 128MB Flash memory
Processor: Marvell PXA300 XScale 624 MHz
Dimensions (W x D x H):
149 mm x 145 mm x 306 mm
(5.8 in x 5.7 in x 12.0 in)
Weight (approx.)
- Nivo 1.C, Nivo 2.C Main unit
(without batteries): 3.9 kg (8.6 lb)
- Nivo 3.C, Nivo 5.C Main Unit
(without batteries): 3.8 kg (8.4 lb)
- Battery: 0.1 kg (0.2 lb)
- Carrying case: 2.3 kg (5.1 lb)
Power
Internal Li-ion battery (x2)
Output voltage: 3.8 V DC
Operating time
8
- Nivo 1.C, Nivo 2.C
approx. 12 hours
(continuous distance/angle measurement)
approx. 26 hours
(distance/angle measurement every 30 s)
approx. 28 hours
(continuous angle measurement)
- Nivo 3.C, Nivo 5.C
approx. 7.5 hours
(continuous distance/angle measurement)
approx. 16 hours
(distance/angle measurement every 30 s)
approx. 20 hours
(continuous angle measurement)
Charging time: Full charge - 4 hours
Tilt Sensor
Type: Dual-axis
Method: Liquid-electric detection
Compensation range: ±3.5’
Communications
Communication ports: 1 x serial
(RS-232C), 2 x USB (host and client)
Wireless communications:
Integrated Bluetooth
Environmental Conditions
Operating temperature range:
–20 °C to +50 °C
Storage temperature:
–25 °C to +60° C
Atmospheric correction
- Temperature range: –40 °C to +60 °C
- Barometric pressure: 400 mmHg to 999
mmHg/533 hPa to 1,332 hPa/15.8 inHg
to 39.3 inHg
Dust and water protection:
IP66 (Nivo1.C IP56)
Certication
Class B Part 15 FCC certication,
CE Mark approval. C-Tick.
Laser safety IEC 60825-1 am2:2007
Prism mode: Class 1 laser
Laser plummet (optional): Class 2 laser
Nivo 1.C ,Nivo 2.C Reectorless / Laser
Pointer: Class 3R laser
Nivo 3.C, Nivo 5.C Reectorless / Class 1 laser
Nivo 3.C, Nivo 5.C Laser Pointer: Class 2 laser
(1) Measuring distance may vary depending on targets and
measuring conditions.
(2) Good conditions (good visibility, overcast, twilight,
underground, low ambient light).
(3) Normal conditions (normal visibility, object in the shadow,
moderate ambient light).
(4) Difcult conditions (haze, object in direct sunlight, high
ambient light).
(5) ±(3+3 ppm × D) mm –20 °C to –10 °C, +40 °C to +50 °C
(6) Measuring time may vary depending on measuring distance
and conditions. For the initial measurement, it may take a
few more seconds.
(7) Battery life specication at 25 °C. Operation time may be shorter
in low temperatures or if the battery is not new.
(8) Kodak Gray Card, Catalog number E1527795.
Specications are subject to change without prior notice.
Bluetooth type approvals are country specic.
Nivo C Series Total Station
©2014 Trimble Navigation Limited. All rights reserved. Nikon is a registered trademark of Nikon Corporation. All other trademarks are the property of their respective owners.
www.spectraprecision.com
Contact Information:
AMERICAS
Spectra Precision Division
10368 Westmoor Drive
Westminster, CO 80021, USA
+1-720-587-4700 Phone
888-477-7516 (Toll Free in USA)
EUROPE, MIDDLE EAST AND AFRICA
Spectra Precision Division
Rue Thomas Edison
ZAC de la Fleuriaye - CS 60433
44474 Carquefou (Nantes), France
+33 (0)2 28 09 38 00 Phone
ASIA-PACIFIC
Spectra Precision Division
80 Marine Parade Road
#22-06, Parkway Parade
Singapore 449269, Singapore
+65-6348-2212 Phone