47
Clicking in a row inside the table allows you to edit the
session individually. The changes are then entered by
clicking on the Manual Set button
Note that the Use button is checked by default, which
means data recording is allowed during the session.
Starting Sessions
& Managing Raw
Data Files
To start the execution of the programmed sessions on the
current day, do the following:
• Click on Sessions - Settings
• Enable the Run Sessions check box.
• Keep default values for Reference Day (“1”), Offset Per Day
(“00:00”) and Recording and Output Elevation Mask (5°).
• Choose the storage medium. “Internal Memory” is about
95 Mbytes in size. Using an external device connected to
the receiver’s USB port (“USB Device”) may allow the
receiver to operate with an even larger memory.