Instruction Manual
44
you are using should be able to give you all this
information):
– Internet Protocol: Choose the Internet protocol (TCP or
UDP) allowing the modem to perform an Internet
connection.
– Access Point: Enter the URL of the mobile
communication provider.
– Access Point Login: Enter the login of the mobile
communication provider.
– Password: Enter the password of the mobile
communication provider.
• Click on the Configure button.
• Now please follow all the steps described in section
General Parameters on page 35 and then proceed with the
steps below.
• Still on the Base Setup page, make sure the Connection
fields in the Serial Port x panes are all set to “None/Cable”
•In the Network 1 pane, choose “Modem Direct IP - Port E”
in the Connection field.
• The base being necessarily a client, enter the information
(Connect Now, Address, Port) allowing it to connect to the
rover (the server) to which it is supposed to deliver
corrections. No Login or Password is needed in this case.
Enable Connect Now to allow the receiver to establish the
connection right after you have clicked on Configure.
•In the Differential Stream 1 pane, choose Port= “E - Modem”
as the output port delivering the generated differential
data. In the Message field, choose the type of differential
message provided through this port (ATOM, RTCM, CMR,
CMR+ or DBEN).
NOTE: The receiver has been designed to offer two
separate and independent differential data outputs. Each
one can output a specific type of differential message. If
only one output is used, select Port=“None” for the other
output.
• Click on the Configure button to let the Web Server load all
your new parameters to the receiver. You have now
reached the end of the configuration phase.