Instruction Manual
46
• Still on the Base Setup page, make sure the Connection
fields in the Serial Port x panes are all set to “None/Cable”
•In the Network x pane, choose “Ethernet Direct IP - Port P”
in the Connection field.
• Because the base is necessarily a client, enter the
information (Connect Now, Address, Port) allowing it to
connect to the rover (the server) to which it is supposed to
deliver its corrections. No Login or Password is needed in
this case.
Enable Connect Now to allow the receiver to establish the
connection right after you have clicked on Configure.
• In the corresponding Differential Stream x pane, choose
Port= “P - Ethernet” as the output port delivering the
generated differential data. In the Message field, choose
the type of differential message provided through this port
(ATOM, RTCM, CMR, CMR+ or DBEN).
NOTE: The receiver has been designed to offer two
separate and independent differential data outputs. Each
one can output a specific type of differential message. If
only one output is used, select Port=“None” for the other
output.
• Click on the Configure button to let the Web Server load all
your new parameters to the receiver. You have now
reached the end of the configuration phase.
NTRIP Server Via
Modem
CAREFUL: In the RTCM sense, an “NTRIP server” is a source
of corrections feeding an NTRIP caster (see RTCM paper
200-2004/SC104-ST). But from the point of view of the
network terminology, an “NTRIP server” is a client, not a
server.
The internal modem should be configured first:
• Click on the Connections menu and then on the Bluetooth/
Modem sub-menu.
Modem
ProFlex 800
(Mobile Wireless
Communication)
Internet
(Client)
IP address
or server name
NTRIP Caster
Users