Installation Instructions for Dryers Original Instructions Keep These Instructions for Future Reference. CAUTION: Read the instructions before using the machine. (If this machine changes ownership, this manual must accompany machine.) www.alliancelaundry.com Part No.
IMPORTANT: The electrical installation in the site shall comply with the Australian Electrical Standards, AS3000, SAA wiring rules, and such local regulations that might apply. In Australia and New Zealand, installation must comply with the Gas Installations Standard AS/NZA 5601 Part 1: General Instructions. WARNING • • Read complete Installation and Operation Instructions before using unit. • The maximum drying load dry weight shall not exceed 9.0 kg [20 pounds].
Table of Contents ...............................................................................................................3 Dimensions............................................................................................. 5 Installation............................................................................................. 7 Before You Start............................................................................................. 7 Supplies...............................................
Dimensions Dimensions Electric Dryers A E F D B C K M G L J H I DRY2275N_SVG A 569 mm [22.38 in.] B 203 mm [8.0 in.] C * 914 mm [36 in.] D * 1022 mm [40.25 in.] E * 1092 mm [43 in.] F 391 mm [15.4 in.] G * 392 mm [15.44 in.] H 683 mm [26.875 in.] I * 102 mm [4.0 in.] J 11 mm [0.4 in.] K * 114 mm [4.5 in.] L 711 mm [28 in.] M 597 mm [23.5 in.] NOTE: Exhaust openings are 102 mm [4 inch] metal ducting.
Dimensions Gas Dryers A E F D B G C M H L O I N J K DRY2276N_SVG 1. 3/8 in. N.P.T. Gas Connection A 569 mm [22.38 in.] B 203 mm [8.0 in.] C * 914 mm [36 in.] D * 1022 mm [40.25 in.] E * 1092 mm [43 in.] F 391 mm [15.4 in.] G * 392 mm [15.44 in.] H * 70 mm [2.8 in.] I 60 mm [2.3 in.] J 683 mm [26.875 in.] K * 102 mm [4.0 in.] L 10 mm [0.4 in.] M * 114 mm [4.5 in.] N 711 mm [28 in.] O 597 mm [23.5 in.] NOTE: Exhaust openings are 102 mm [4 inch] metal ducting.
Installation Installation Before You Start 3. Connect dryer to exhaust system. 4. For gas models only, connect the gas supply pipe. Check for gas leaks. 5. Reverse the door, if desired. 6. Wipe out the inside of the dryer. 7. Connect the dryer to electrical power. 8. Recheck steps. 9. Start and run the dryer in a heat setting to verify dryer is heating. Supplies For most installations, the basic supplies you will need are: 2 1 3 Position Dryer Near Installation Area Position and Level the Dryer 1.
Installation 2 1 3 D669I_SVG 1. Dryer Base 2. Level 3. Leveling Leg Figure 2 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 8 Part No.
Installation Front View (Without Closet Door) B A A DRY2663N_SVG Side View (Closet Door) 1 D E A C H 3 DRY2664N_SVG Front View (Closet Door) F 2 (G) F DRY2637N_SVG 1. Closet Door 2. Centered Air Openings (G) (2 Openings minimum) 3. Outer Wall of Enclosure Figure 3 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 9 Part No.
Installation Area Free Standing/Alcove Installation Description Closet Installation A* Dryer sides and rear clearance 0 mm [0 in.] 0 mm [0 in.] B Dryer top clearance 305 mm [12 in.] 305 mm [12 in.] C Dryer front clearance Not Applicable 51 mm [2 in.] D Exhaust duct clearance to com- 51 mm [2 in.] bustible material 51 mm [2 in.] E Weather hood to ground clearance 305 mm [12 in.] 305 mm [12 in.] F Distance from floor or ceiling to air opening edge Not Applicable 76 mm [3 in.
Installation • WARNING To reduce the risk of fire, DO NOT use plastic or thin foil ducting to exhaust the dryer. • W354 • • • D314I_SVG D315I_SVG • • Figure 4 • • • • • • • • • • • • • DO NOT use plastic, thin foil or type B ducting. Rigid metal duct is recommended. Locate dryer so exhaust duct is as short as possible. Be certain old exhaust ducts are cleaned before installing your new dryer. Use 102 mm [4 inch] diameter rigid or flexible metal duct.
Installation Weather Hood Type Number of 90° Elbows Recommended Use Only for Short Run Installations 1 1 D673I_SVG 1. 102 mm [4 in.] 1 D802I_SVG 1. 64 mm [2.5 in.] Maximum length of 102 mm [4 in.] diameter rigid metal duct. 0 19.8 m [65 feet] 16.8 m [55 feet] 1 16.8 m [55 feet] 14.3 m [47 feet] 2 14.3 m [47 feet] 12.5 m [41 feet] 3 11.0 m [36 feet] 9.1 m [30 feet] 4 8.5 m [28 feet] 6.7 m [22 feet] Table 2 NOTE: Natural gas, 37.3 MJ/m3 [1000 Btu/ft3], service must be supplied at 1.
Installation Gas Supply Pres- Natural sure L.P. 1.13 kPa 2.75 kPa WARNING To reduce the risk of gas leaks, fire or explosion: • • • • • • The dryer must be connected to the type of gas as shown on nameplate located in the door recess. Use a new flexible stainless steel connector. Use pipe joint compound insoluble in L.P. (Liquefied Petroleum) Gas, or Teflon tape, on all pipe threads. Purge air and sediment from gas supply line before connecting it to the dryer.
Installation L.P. Altitude Adjustments Altitude Orifice Size m [ft] 3000 [9500] mm [inches] No. 57 1.1 [0.0430] B Part Number A 60941 DRY1916N_SVG Table 4 Figure 8 Reverse Door, if Desired 4. Rotate door panel 180 degrees as shown. The door on this dryer is completely reversible. To reverse door proceed as follows: 1. Remove four hinge attaching screws. D273P_SVG Figure 9 5. Remove door strike from door liner and reinstall on opposite side. D675I_SVG Figure 6 2. Remove all nine screws.
Installation DRY1919N_SVG Figure 12 8. Using screwdriver, remove two door plugs, and reinstall on opposite side of door opening. D618I_SVG Figure 15 Connect Dryer to Electrical Power Electrical Requirements Electric Dryer D620I_SVG NOTE: The wiring diagram is located in the control hood. WARNING Figure 13 9. Reinstall four hinge attaching screws, removed in Step 1.
Installation If the supply cord is damaged, it must be replaced by the manufacturer, its special agent or similarly qualified persons in order to avoid a hazard. CAUTION If this appliance is supplied from a cord extension set or an electrical portable outlet device, the cord extension set or electrical portable outlet device must be positioned so that it is not subject to splashing or ingress of moisture.
Installation IMPORTANT: If all air is not purged out of gas line, gas igniter may go off before gas is ignited. If this happens, after approximately two minutes igniter will again attempt gas ignition. WARNING Improper connection of the equipment earth/ground conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the dryer is properly earthed.
Installation Shut-off Valve Only Applicable on Certain Models 5 1 6 4 3 2 DRY2753N_SVG 1. 2. 3. 4. 5. 6. Air Shutter Lockscrew Air Shutter 3.1 mm [1/8 in.] Pipe Plug (For checking manifold pressure) Shut-off Valve Open Position Shut-off Valve Closed Position Shut-off Valve Handle Figure 18 All Dryers If the dryer heat source is not functioning correctly, refer to the Troubleshooting section of the Dryer User’s Guide for corrective action.
Installer Checklist Installer Checklist Fast Track for Installing the Dryer 1 Position Dryer Near Installation Area. 6 CHECK Wipe Out Inside of Dryer. CHECK DRY1954N_SVG Position and Level the Dryer 7 Connect the Dryer to Electrical Power. Electric 25 CHECK A CHECK 20 0V 2 D670I_SVG Gas DRY2634N_SVG 10A 25 0 V D671I_SVG 3 Connect Dryer Exhaust System. 8 CHECK Recheck Steps. CHECK DRY688N_SVG 4 GAS DRYERS ONLY • Connect Gas Supply Pipe. • Check for Gas Leaks.