Installation Instructions for Topload Washers Original Instructions Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.speedqueen.com Part No.
Table of Contents Dimensions and Specifications ............................................................... 4 Installation............................................................................................. 5 Before You Start............................................................................................. 5 Supplies..................................................................................................... 5 Parts Included....................................................
Dimensions and Specifications Dimensions and Specifications A B C D H G I J F E TLW2162N_SVG A 28 in. [711 mm] B 22.13 in. [562 mm] C *40.77 in. [1036 mm] D *53 in. [1346 mm] E 26 in. [660 mm] F 0.4 in. [10 mm] G 25.63 in. [651 mm] H *29 in. [737 mm] I *43 in. [1092 mm] J *36 in. [914 mm] *With leveling legs turned into base. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 4 Part No.
Installation Installation Before You Start • • • • • • Supplies For most installations, the basic supplies you will need are: 2 Two fill hoses with washers and filter screens Four rubber feet Beaded strap Installation Instructions User’s Guide Warranty Bond Order of Installation Steps 1 3 The proper order of steps must be followed to ensure correct installation. Refer to the list below when installing your unit. 1. 2. 3. 4. 5. 6. 7. 8. 9. 4 5 6 7 Remove the Shipping Brace and Shipping Plug 1.
Installation Connect Fill Hoses WARNING Under certain conditions, hydrogen gas may be produced in a hot water system that has not been used for two weeks or more. HYDROGEN GAS IS EXPLOSIVE. If the hot water system has not been used for such a period and before using the washer, turn on all hot water faucets and let the water flow from each for several minutes. This will release any accumulated hydrogen gas. The gas is flammable. Do not smoke or use an open flame during this time.
Installation NOTE: Water pressure under 20 pounds per square inch [138 kPa] will cause an extended fill time in the washer. 4 COLD Turn on the water supply faucets and flush the lines for approximately two minutes to remove any foreign materials that could clog the screens in the water mixing valve. This is especially important when installing your washer in a newly constructed or renovated building. Build-up may have occurred during construction.
Installation IMPORTANT: To prevent siphoning, do not place any ribbed portion of the drain hose into the standpipe. 3. Remove the beaded strap from accessories bag and place around standpipe and drain hose, approximately 12 inches [300 mm] down from the top of pipe. Refer to Figure 5 . 4. Tighten strap to hold hose to standpipe. This will prevent the drain hose from dislodging from drain receptacle during use. 1 1 3 2 6 2 TLW2221N_SVG 1. 562P3 Siphon Break Kit 2. Standpipe 3.
Installation 4. Place rubber cups (from accessories bag) on all four leveling legs. fer to Figure 8 . Use the beaded strap (supplied in accessories bag) to secure hose. We recommend leaving the standpipe adapter on the drain hose for this type of installation. 1 5 1 2 3 4 TLW2222N_SVG 1. Beaded Strap (tape if necessary) 1. 2. 3. 4. 5. Figure 8 Position and Level the Washer 1. Position washer so it has sufficient clearance for installation and servicing. 2.
Installation Standard 120 Volt, 60 Hertz 3-Wire Effective Earth/ Ground Circuit WARNING To reduce the risk of fire, electric shock, serious injury or death, all wiring and protective earth/ground connections MUST conform with the latest edition of the National Electrical Code, ANSI/NFPA No. 70, and such local regulations as might apply.
Installation led and connected to a protective earth/ground in accordance with all local codes and ordinances. WARNING Improper connection of the equipment earth/ground conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the unit is properly connected to a protective earth/ground.
Installer Checklist Installer Checklist Fast Track for Installing the Washer 1 Remove the Shipping Brace and Shipping Plug. 5 CHECK Position and Level the Washer. CHECK TLW2201N_SVG TLW1975N_SVG1 2 Wipe Out Inside of Washtub. 6 CHECK Plug In the Washer. CHECK TLW2009N_SVG D254I_SVG 3 Connect Fill Hoses. 7 COLD Add Water to the Washer. HOT CHECK CHECK TLW1988N_SVG 4 Connect Drain Hose to Drain Receptacle. W391I_SVG 8 CHECK Check Lid Switch.