Installation Instructions for Dryers Original Instructions Keep These Instructions for Future Reference. CAUTION: Read the instructions before using the machine. (If this machine changes ownership, this manual must accompany machine.) Part No.
WARNING IMPORTANT: Purchaser must consult the local gas supplier for suggested instructions to be followed if the dryer user smells gas. The gas utility instructions plus the SAFETY and WARNING note directly above must be posted in a prominent location near the dryer for customer use. WARNING Risk of fire. Highly flammable material. WARNING W881 Read all instructions before using unit.
The following information applies to the state of Massachusetts, USA. • • • • This appliance can only be installed by a Massachusetts licensed plumber or gas fitter. This appliance must be installed with a 36 inch [910 mm] long flexible gas connector. A “T-Handle” type gas shut-off valve must be installed in the gas supply line to this appliance. This appliance must not be installed in a bedroom or bathroom. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 4 Part No.
Table of Contents Dimensions............................................................................................. 6 Installation............................................................................................. 8 Before You Start............................................................................................. 8 Supplies..................................................................................................... 8 Parts Included..........................................
Dimensions Dimensions Electric Dryers A 22.38 in. [569 mm] B 8.0 in. [203 mm] C * 36 in. [914 mm] D (to controls) Electronic Control: *41.25 in. [1048 mm] Knob Control: *40.75 [1035 mm] E * 42.75 in. [1086 mm] F 15.4 in. [391 mm] G * 15.44 in. [392 mm] H 26.875 in. [683 mm] I * 4.0 in. [102 mm] J 0.4 in. [11 mm] K * 4.5 in. [114 mm] L 28 in. [711 mm] M 23.5 in. [597 mm] NOTE: Exhaust openings are 4 inch [102 mm] metal ducting.
Dimensions Gas Dryers 1. 3/8 in. N.P.T. Gas Connection A 22.38 in. [569 mm] B 8.0 in. [203 mm] C * 36 in. [914 mm] D Electronic Control: *41.25 in. [1048 mm] Knob Control: *40.75 [1035 mm] E * 42.75 in. [1086 mm] F 15.4 in. [391 mm] G * 15.44 in. [392 mm] H * 2.8 in. [70 mm] I 2.3 in. [60 mm] J 26.875 in. [683 mm] K * 4 in. [102 mm] L 0.4 in. [10 mm] M * 4.5 in. [114 mm] N 28 in. [711 mm] O 23.5 in. [597 mm] NOTE: Exhaust openings are 4 inch [102 mm] metal ducting.
Installation Installation Before You Start • Supplies • For most installations, the basic supplies you will need are: • 1 2 3 4 Three screws (electric dryers only). Refer to Electric Dryer Only - Connect Electrical Plug. One filter screen washer (steam models only). Refer to Steam Dryers - Connect Water Inlet Hose. One plain rubber washer (steam models only). Refer to Steam Dryers - Connect Water Inlet Hose. Order of Installation Steps 1. 2. 3. 4. Position and level the dryer.
Installation 1. Dryer Base 2. Level 3. Leveling Leg Figure 2 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 9 Part No.
Installation Front View (Without Closet Door) B A A DRY2663N_SVG Side View (Closet Door) Front View (Closet Door) F 2 (G) F DRY2637N_SVG 1. Closet Door 2. Centered Air Openings (G) (2 Openings minimum) 3. Outer Wall of Enclosure Figure 3 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 10 Part No.
Installation Area Free Standing/Alcove Installation Description Closet Installation A* Dryer sides and rear clearance 0 in. [0 mm] 0 in. [0 mm] B Dryer top clearance 12.25 in. [305 mm] 12.25 in. [305 mm] C Dryer front clearance Not Applicable 2 in. [51 mm] D Exhaust duct clearance to com- 2 in. [51 mm] bustible material 2 in. [51 mm] E Weather hood to ground clearance 12 in. [305 mm] 12 in. [305 mm] F Distance from floor or ceiling to air opening edge Not Applicable 3 in.
Installation 11. Check that Y-connector valves are open (if applicable). 12. Turn water on and check for leaks. Wait 30 minutes and check again, some leaks are slow to show up. 13. If leaks are found, check and retighten the hose couplings. WARNING To reduce the risk of fire, DO NOT use plastic or thin foil ducting to exhaust the dryer. NOTE: If leaks persist after checking and retightening hose coupling, check for crossing threading, and damaged hose(s) or rubber washer(s).
Installation • Exhaust duct must not be connected to any other duct, vent, or chimney. Dryer exhausts 220 cfm per unit (measured at back of dryer). DO NOT install flexible duct in concealed spaces, such as a wall or ceiling. Static pressure in exhaust duct should not be greater than 0.6 inches water column [1.5 cm water column], measured with manometer placed on exhaust duct 2 feet [610 mm] from dryer (check with dryer running and no load).
Installation NOTE: The maximum length of a 4 in. [102 mm] diameter flexible metal duct must not exceed 7.87 ft. [2.4 m], as required to meet UL2158, clause 7.3.2.A. Natural Gas Altitude Adjustments Altitude Gas Dryers - Connect Gas Supply Pipe feet [m] WARNING To reduce the risk of gas leaks, fire or explosion: • • • • • • The dryer must be connected to the type of gas as shown on nameplate located in the door recess. Use a new flexible stainless steel connector.
Installation L.P. Altitude Adjustments 1 Altitude 5 feet [m] Orifice Size No. inches [mm] Part No. 2 3 4 3000 [915] 55 0.0520 [1.32] 58755 8000 [2440] 56 0.0465 [1.18] D503786 Table 4 Connect Electrical Plug (Electric Dryer Only) D233I_SVG 1. New Stainless Steel Flexible Connector – (Use design CSA certified connector) Use only if allowed by local codes 2. 1/8 in. NPT Pipe Plug 3. Equipment Shut-Off Valve 4. Black Iron Pipe: Shorter than 20 ft. [6.1 m] – Use 3/8 in. [9.5 mm] pipe.
Installation WARNING Wire Length Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the dryer is properly grounded. W038 Do not modify the plug proivded with the cord-kit - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
Installation 6 7 8 1 9 14 4 10 5 11 2 2 12 13 3 16 L1 L2 15 L1 L2 D816I_SVG 1. A typical 30-Amp Three-Wire Receptacle NEMA Type 10-30R 2. 120 ± 12 V.A.C. 3. 240 ± 12 V.A.C. 4. Intermediate Fuse Box (may be omitted if service entrance box is fused) 5. Wall Receptacle 6. Power Supply 7. 3-Wire Earth/Ground Neutral 120/240 Volt, 60 Hertz AC 1 Phase Service Entrance Switch Box (Refer to NOTE above) 8. 30 Ampere Fuses or Circuit Breaker 9. Neutral Wire 10.
Installation 3. Use a strain relief and insert end of power cord through power supply hole. 2 1 3 4 7 7 6 Figure 8 7 5 7 D696I_SVG 4. Use the three screws from the accessories bag to attach the power cord wires to the terminal block. Refer to Figure 9 . DRY2016N_SVG 3-Wire Connection 1. 2. 3. 4. 5. 6. 7. 1 2 Typical Four-Wire Receptacle Power Cord – Not Supplied with Dryer Strain Relief Nut Strain Relief 0 V.A.C. 240 ± 12 V.A.C. 120 ± 12 V.A.C. Figure 10 4 3 1. Disconnect power to dryer.
Installation 4-Wire Connection 8 1 7 1 2 DRY2468N_SVG 1. Earth/Ground Screw 3 6 Figure 12 DRY2482N_SVG 1. 2. 3. 4. 5. 6. 7. 8. DRY2469N_SVG 1. Strain Relief Figure 13 5. Attach power cord earth/ground (green) wire to rear bulkhead using earth/ground screw removed in Step 3. 4 5 4. Use a strain relief and insert end of power cord through power supply hole. Neutral Terminal “L2” Terminal Black White Earth/Ground Red “L1” Terminal Earth/Ground to Neutral Wire Figure 14 6.
Installation The door on this dryer is completely reversible. To reverse door proceed as follows: 1. Remove four hinge attaching screws. D273P_SVG Figure 18 D675I_SVG 5. Remove door strike from door liner and reinstall on opposite side. Figure 15 2. Remove all nine screws. DRY1917N_SVG Figure 19 D272P_SVG 6. Insert liner under flange on bottom of door, then push top of door liner into place. Figure 16 3. Pull bottom of door liner out, then pull down, removing door liner from door panel.
Installation 8. Using screwdriver, remove two door plugs, and reinstall on opposite side of door opening. Plug In the Dryer This appliance is to be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA. WARNING The appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by a utility. D317S_SVG Figure 22 9.
Installation • • • • Do not overload circuits. Do not use an adapter. Do not use an extension cord. Do not operate both a washer and gas dryer on the same circuit. Use separately fused 15 amp circuits. The dryer is designed to be operated on a separate branch, polarized, three-wire, effectively grounded, 120 Volt, 60 Hertz, AC (alternating current) circuit protected by a 15 Ampere fuse, equivalent fusetron or circuit breaker.
Installation Electric Dryers 1. Close the loading door and start the dryer in a heat setting (refer to the operation instructions). 2. After the dryer has operated for three minutes, the exhaust air or exhaust pipe should be warm. Gas Dryers IMPORTANT: This operation is to be conducted by qualified personnel only. 1. To view the burner flame, remove the lower front panel of the dryer. 2. Close the loading door and start the dryer in a heat setting (refer to the operation instructions).
Installer Checklist Installer Checklist Fast Track for Installing the Dryer 1 Position and Level the Dryer. 6 CHECK Reverse Door, if Desired. CHECK DRY2634N_SVG D675I_SVG1 2 STEAM MODELS ONLY 7 COLD COLD HOT Wipe Out Inside of Dryer. HOT Connect Water Inlet Hose. C H C H CHECK 3 DRY2866N_SVG1 Connect Dryer Exhaust System. CHECK DRY2869N_SVG1 8 CHECK Plug In the Dryer. Electric CHECK D275I_SVG1 Gas TLW2289N_SVG 4 GAS ONLY • • 9 Connect Gas Supply Pipe. Check for Gas Leaks.