Installation and Maintenance Instructions for Drying Tumblers 30 Pound (13 Kg) Capacity JCB30CE, JCB30CG, JCB30CSH, JCB30CSL, JCB30WE, JCB30XG, SCB30CE, SCB30CG, SCB30CSH, SCB30CSL, SCB30WE and SCB30XG 50 Pound (22 Kg) Capacity JC50CE, JC50CG, JC50CSH, JC50EG, JCB50CE, JCB50CG, JCB50CSH, JCB50EG, SC50CE, SC50CG, SC50CSH, SC50EG, SCB50CE, SCB50CG, SCB50CSH and SCB50EG 75 Pound (34 Kg) Capacity JC75CE, JC75CG, JC75CSH, JCB75CE, JCB75CG, JCB75CSH, SC75CE, SC75CG, SC75CSH, SCB75CE, SCB75CG and SCB75CSH ATTENTI
WARNINGS AND LABELS aWARNING FAILURE TO INSTALL, MAINTAIN, AND/OR OPERATE THIS MACHINE ACCORDING TO MANUFACTURER’S INSTRUCTIONS MAY RESULT IN CONDITIONS WHICH CAN PRODUCE SERIOUS INJURY, DEATH AND/OR PROPERTY DAMAGE. NOTE: The WARNING and IMPORTANT instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and carefulness are factors which CANNOT be built into this tumbler.
維 WARNING To reduce the risk of fire, electric shock, serious injury or death to persons when using your dryer, follow these basic precautions: 1. Do not allow children to play on or in the tumbler. Close supervision of children is necessary when the tumbler is used near children. This is a safety rule for all appliances. 2. Before the tumbler is removed from service or discarded, remove the door to the drying compartment. 3.
TABLE OF CONTENTS Electrical Requirements: 30 Pound (13 kg) Narrow Cabinet Tumblers ...... 30 Pound (13 kg) Tumblers ................................ 50 Pound (22 kg) Tumblers ................................ 75 Pound (34 kg) Tumblers ................................ Electrical Connections ............................................ Positioning the Drying Tumbler .............................. Leveling the Drying Tumbler .................................. Gas Requirements (Gas Drying Tumblers) ............
NAMEPLATE LOCATION IMPORTANT When writing for information on any tumbler, be sure to mention model and serial numbers. The model and serial numbers will be found on the nameplate as shown on rear of tumbler or underneath the door hinge. T238IE3A IMPORTANT When writing for information on any tumbler, be sure to mention model and serial numbers. The model and serial numbers will be found on the nameplate as shown on the rear of tumbler or underneath the door hinge.
SECTION I Roughing-In Dimensions and Specifications 30 Pound (13 kg) Narrow Cabinet Gas Tumbler SIDE PANEL 67.95 cm (26-3/4") 8.59 cm (3-3/8") 8.59 cm (3-3/8") T024IE3B TOP VIEW OF EXHAUST 3.81 cm (1-1/2") 81.76 cm (32-3/16") 113.98 cm (44-7/8") DISCONNECT SWITCH T258IE3A 15.24 cm (6") DIAMETER EXHAUST AIR FLOW SWITCH 183.52 cm (72-1/4") GAS CONNECTION AND SHUT OFF VALVE ELECTRICAL JUNCTION BOX 71.
30 Pound (13 kg) Narrow Cabinet Gas Tumbler Cabinet Finish: Electrostatically applied thermosetting polyester. Cylinder: 26.5" x 30" (67.3 cm x 76.2 cm) perforated galvanized steel with three baffles Motor: ¹⁄₃ H.P., lifetime lubricated, internal overload protected Electrical Requirements: 230 Volt, 50 Hertz, 1 Phase; 5.5 Amps Gas Consumption: 75,000 BTU per hour (79.1 MJ/hr.) Gas Connection: 1/2" (12.7 mm) N.P.T.
30 Pound (13 kg) Narrow Cabinet Electric Tumbler SIDE PANEL 67.95 cm (26-3/4") 8.59 cm (3-3/8") 8.59 cm (3-3/8") T024IE3B TOP VIEW OF EXHAUST 3.81 cm (1-1/2") 81.76 cm (32-3/16") 113.98 cm (44-7/8") T258IE3A DISCONNECT SWITCH 15.24 cm (6") DIAMETER EXHAUST 183.52 cm (72-1/4") ELECTRICAL JUNCTION BOX CLEARANCES: Minimum to nearest Combustible Material Top — 12" (30.5 cm) Minimum. 0" permitted for first 4" (10.2 cm) along front of machine.
30 Pound (13 kg) Narrow Cabinet Electric Tumbler Cabinet Finish: Electrostatically applied thermosetting polyester. Cylinder: 26.5" x 30" (67.3 cm x 76.2 cm) perforated galvanized steel with three baffles Motor: ¹⁄₃ H.P.
30 Pound (13 kg) Gas Tumbler CLEARANCES: Minimum to nearest Combustible Material Top — 12" (30.5 cm) Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm) Minimum recommended for service access. Sides — 0" Permitted. 71.5 cm (28-1/4") 3.81 cm (1-1/2") 81.75 cm (32-3/16") 114 cm (44-7/8") 118.6 cm (46-11/16") DISCONNECT SWITCH GAS CONNECTION AND SHUT OFF VALVE AIR FLOW SWITCH (Standard Models) 20.
30 Pound (13 kg) Gas Tumbler Cabinet Finish: Electrostatically applied thermosetting polyester Cylinder: 30" x 30" (76.2 x 76.2 cm) perforated galvanized steel with three baffles; 30 pounds (13.6 kg) dry weight (cotton load) Motor: ¹⁄₃ H.P., lifetime lubricated, internal overload protected Electrical Requirements: 230 Volt, 50 Hertz, 1 Phase, 5.5 Amp Gas Consumption: Energy Saver Models — 80,000 BTU per hour (84.4 MJ/hr.) Standard Models — 105,000 BTU per hour (110.8 MJ/hr.
30 Pound (13 kg) Electric Tumbler CLEARANCES: Minimum to nearest Combustible Material Top — 12" (30.5 cm) Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm) Minimum recommended for service access. Sides — 0" Permitted. 71.7 cm (28-1/4") 3.81 cm (1-1/2") 81.75 cm (32-3/16") DISCONNECT SWITCH 114 cm (44-7/8") ELECTRICAL JUNCTION BOX 183.5 cm (72-1/2") 11.3 cm (4-7/16") 20.3 cm (8") DIAMETER EXHAUST DUCT THIMBLE CONNECTION 55.
30 Pound (13 kg) Electric Tumbler Cabinet Finish: Electrostatically applied thermosetting polyester Cylinder: 30" x 30" (76.2 x 76.2 cm) perforated galvanized steel with three baffles; 30 pounds (13.6 kg) dry weight (cotton load) Motor: ¹⁄₃ H.P.
30 Pound (13 kg) Steam Tumbler CLEARANCES: Minimum to nearest Combustible Material Top — 12" (30.5 cm) Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm) Minimum recommended for service access. Sides — 0" Permitted. 71.75 cm (28-1/4") 3.81 cm (1-1/2") 81.75 cm (32-3/16") 114 cm (44-7/8") (High Pressure Models) 114.4 cm (45-1/32") (Low Pressure Models) DISCONNECT SWITCH 35.6 cm (14") 19.05 cm (7-1/2") 1.9 cm (3/4") I.D.
30 Pound (13 kg) Steam Tumbler Cabinet Finish: Electrostatically applied thermosetting polyester Cylinder: 30" x 30" (76.2 x 76.2 cm) perforated galvanized steel with three baffles; 30 pounds dry weight (13.6 kg) (cotton load) Motor: High Pressure (4 coils) ¹⁄₂ H.P. Low Pressure (4 coils) ³⁄₄ H.P. Boiler Horsepower: 4 coil High Pressure – 3.7 Bhp (123,950 BTU/hr., 58 kg/hr, 31,235 kCal/hr.) 4 coil Low Pressure – 2.6 Bhp (87,100 BTU/hr., 40 kg/hr, 21,949 kCal/hr.
50 Pound (22 kg) Gas Non-reversing Tumblers CLEARANCES: Minimum to nearest Combustible Material Top — 12" (30.5 cm) Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm) Minimum recommended for service access. Sides — 0" Permitted. 71.75 cm (28-1/4") 3.81 cm (1-1/2") 81.75 cm (32-3/16") 119.4 cm (47") DISCONNECT SWITCH 146.37 cm (57-5/8") 167 cm (65-3/4") 13.65 cm (5-3/8") 20.
50 Pound (22 kg) Gas Tumblers Cabinet Finish: Electrostatically applied thermosetting polyester Cylinder: 37" x 30" (94 cm x 76.2 cm) perforated galvanized steel with four baffles; 50 pounds (22.7 kg) dry weight (cotton load) Motor: (Nonreversing Models) 1/2 H.P., lifetime lubricated, internal overload protected (See below for reversing models.) Electrical Requirements: Non-Reversing Models 230 Volt, 50 Hertz, 1 Phase, 6.
50 Pound (22 kg) Gas and Steam Reversing Tumblers ELECTRICAL JUNCTION BOX DISCONNECT SWITCH CYLINDER MOTOR 20.3 cm (8") DIAMETER EXHAUST THIMBLE CONNECTOR (Energy Saver Gas Models) 194.6 cm (76-5/8") 146.4 cm (57-5/8") 20.3 cm (8") DIAMETER EXHAUST THIMBLE CONNECTION AIRFLOW SWITCH 34 cm (13-3/8") FAN MOTOR 13.65 cm (5-3/8") 98.
50 Pound (22 kg) Electric Non-reversing Tumblers CLEARANCES: Minimum to nearest Combustible Material Top — 12" (30.5 cm) Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm) Minimum recommended for service access. Sides — 0" Permitted. 71.75 cm (28-1/4") 3.81 cm (1-1/2") 81.75 cm (32-3/16") DISCONNECT SWITCH 194.6 cm (76-5/8") 20.3 cm (8") DIAMETER EXHAUST DUCT THIMBLE CONNECTION 13.65 cm (5-3/8") 34 cm (13-3/8") ELECTRICAL JUNCTION BOX 119.
50 Pound (22 kg) Electric Tumblers Cabinet Finish: Electrostatically applied thermosetting polyester Cylinder: 37" x 30" (94 x 76.2 cm) perforated galvanized steel with four baffles; 50 pounds (22.7 kg) dry weight (cotton load) Motor: (Nonreversing models) 1/2 H.P., lifetime lubricated, internal overload protected (See below for reversing models.
50 Pound (22 kg) Electric Reversing Tumblers ELECTRICAL JUNCTION BOX DISCONNECT SWITCH CYLINDER MOTOR 194.6 cm (76-5/8") 20.3 cm (8") DIAMETER EXHAUST THIMBLE CONNECTION AIRFLOW SWITCH 34 cm (13-3/8") 13.65 cm (5-3/8") FAN MOTOR 98.
71.75 cm (28-1/4") 203.2 cm (80") (6 Coil) 194. 6 cm (76-5/8") (4 Coil) 50 Pound (22 kg) Steam Non-reversing Tumblers 3.81 cm (1-1/2") 81.75 cm (32-3/16") 119.4 cm (47") 38.7 cm (15-1/4") 19.05 cm (7-1/2") 1.9 cm (3/4") I.D. STEAM INLET 1.9 cm (3/4") I.D. STEAM OUTLET 13.65 cm (5-3/8") 20.3 cm (8") DIAMETER EXHAUST DUCT THIMBLE CONNECTION 34 cm (13-3/8") 164.5 cm (64-3/4") 184.8 cm (72-3/4") (4 Coil) 200 cm (78-3/4") (6 Coil) ELECTRICAL JUNCTION BOX 98.
50 Pound (22 kg) Steam Tumblers Cabinet Finish: Electrostatically applied thermosetting polyester Cylinder: 37" x 30" (94 x 76.2 cm) perforated galvanized steel with four baffles; 50 pounds (22.7 kg) dry weight (cotton load) Motor: (Nonreversing Models) High Pressure Steam — 1/2 H.P. Low Pressure Steam — 3/4 H.P. Both motors are lifetime lubricated, internal overload protected (See below for reversing models.) Boiler Horsepower: High Pressure Steam (6 Coil) — 4.60 BHP (154,100 BTU/hr, 72.
75 Pound (34 kg) Gas Non-reversing Tumblers 71.75 cm (28-1/4") 3.81 cm (1-1/2") 97 cm (38-3/16") 134.6 cm (53") DISCONNECT SWITCH GAS CONNECTION AND SHUT OFF VALVE 167 cm (65-3/4") CLEARANCES: Minimum to nearest Combustible Material Top — 12" (30.5 cm) Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm) Minimum recommended for service access. Sides — 0" Permitted. 194.6 cm (76-5/8") ELECTRICAL JUNCTION BOX 13.65 cm (5-3/8") 20.
75 Pound (34 kg) Gas and Steam Reversing Tumblers ELECTRICAL JUNCTION BOX DISCONNECT SWITCH CYLINDER MOTOR 194.6 cm (76-5/8") 20.3 cm (8") DIAMETER EXHAUST THIMBLE CONNECTION AIRFLOW SWITCH 34 cm (13-3/8") 13.65 cm (5-3/8") FAN MOTOR 98.
75 Pound (34 kg) Gas Tumblers Cabinet Finish: Electrostatically applied thermosetting polyester Cylinder: 37" x 36" (94 x 91.4 cm) perforated galvanized steel cylinder with four baffles; 75 pounds (34.1 kg) dry weight (cotton load) Motor: (Non-reversing models) 3/4 H.P., lifetime lubricated, internal overload protected. (See below for reversing models.) Electrical Requirements Nonreversing Models: 230 Volt, 50 Hertz, 1 Phase, 9.
75 Pound (34 kg) Electric Non-reversing Tumblers CLEARANCES: Minimum to nearest Combustible Material Top — 12" (30.5 cm) Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm) Minimum recommended for service access. Sides — 0" Permitted. 71.75 cm (28-1/4") 3.81 cm (1-1/2") 97 cm (38-3/16") DISCONNECT SWITCH 134.6 cm (53") 194.6 cm (76-5/8") ELECTRICAL JUNCTION BOX 20.3 cm (8") DIAMETER EXHAUST DUCT THIMBLE CONNECTION 13.
75 Pound (34 kg) Electric Reversing Tumblers ELECTRICAL JUNCTION BOX DISCONNECT SWITCH CYLINDER MOTOR 194.6 cm (76-5/8") 20.3 cm (8") DIAMETER EXHAUST THIMBLE CONNECTION AIRFLOW SWITCH 34 cm (13-3/8") 13.65 cm (5-3/8") FAN MOTOR 98.
75 Pound (34 kg) Electric Tumblers Cabinet Finish: Electrostatically applied thermosetting polyester Cylinder: 3 7" x 36" (94 x 91.4 cm) perforated galvanized steel with four baffles; 75 pounds (34.1 kg) dry weight (cotton load) Motor: (Non-reversing models) 3/4 H.P., lifetime lubricated internal overload protected. (See below for reversing models.
194.6 cm (76-5/8") (4 Coil) CLEARANCES: Minimum to nearest Combustible Material Top — 12" (30.5 cm) Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm) Minimum recommended for service access. Sides — 0" Permitted. 71.75 cm (28-1/4") 203 cm (80") (6 Coil) 75 Pound (34 kg) Steam Non-reversing Tumblers 3.81 cm (1-1/2") 97 cm (38-3/16") 134.6 cm (53") DISCONNECT SWITCH 39.1 cm (15-1/4") 19 cm (7-1/2") ELECTRICAL JUNCTION BOX 1.9 cm (3/4") I.D. STEAM INLET 164.
75 (34 kg) Pound Steam Tumblers Cabinet Finish: Electrostatically applied thermosetting polyester Cylinder: 37" x 36" (94 x 91.4 cm) perforated galvanized steel with four baffles; 75 pounds (34.1 kg) dry weight (cotton load) Motor: (Non-reversing models) High Pressure Steam — 3/4 H.P. Low Pressure Steam — 3/4 H.P. Both motors are lifetime lubricated, internal overload protected. (See below for reversing models.) Boiler Horsepower: High Pressure Steam (6 Coil) — 4.60 BPH (154,100 BTU/hr., 72.1 kg/hr.
SECTION II Installation Instructions RECEIVING INSPECTION Upon delivery, visually inspect crate carton and parts for any visible shipping damage. If crate, carton or cover are damaged or signs of possible damage are evident, have carrier note condition on shipping papers before shipping receipt is signed, or advise carrier of condition as soon as it is discovered. Advise carrier of any damaged or missing articles as soon as possible.
Proper sized exhaust ducts are essential for proper operation. All elbows should be sweep type. Do not install elbows with a radius less than shown in table below. Exhaust ducts must be assembled so interior surfaces are smooth to reduce accumulation of lint. Do not use sheet metal screws to join vent sections. Improperly sized or assembled ductwork causes excess back pressure which results in slow drying, lint collecting in duct, lint blowing back into room, and increased fire hazard.
維WARNING To reduce the risk of fire and accumulation of combustible gases, DO NOT exhaust tumbler air into a window well, gas vent, chimney or enclosed, unventilated area such as an attic wall, ceiling, crawl space under a building, or concealed space of a building. 維WARNING Solvent gases and vapors from dry cleaning machines create acids when drawn through the heater of a drying tumbler. These acids are corrosive to the drying tumbler as well as to the laundry load being dried.
VERTICAL EXHAUST INSTALLATION HORIZONTAL EXHAUST INSTALLATION WALL CONNECT TO TUMBLER WALL 2" (5.1 cm) MINIMUM EXHAUST OUTLET EXHAUST AIR FLOW MAXIMUM LENGTH OF DUCT 14 FEET (4.3 m) CONNECT TO TUMBLER NO SCREEN OR CAP T030IE3B NOTE: WHERE THE EXHAUST DUCT PIERCES A COMBUSTIBLE WALL OR CEILING, AN OPENING HAVING A DIAMETER FOUR INCHES (10.2 cm) LARGER THAN THE DIAMETER OF THE EXHAUST DUCT SHALL BE PROVIDED, AND THE EXHAUST DUCT CENTERED WITHIN THE OPENING. 2" (5.
ELECTRICAL REQUIREMENTS For 30 Pound (13 kg) Narrow Cabinet Tumblers REQUIREMENTS Heat Source Electrical Specs Wires Required and Terminal Block Connection Gas 230-50-1 L1 L2 Ground to PE Busbar Electric 230-50-1 L1 L2 Ground to PE Busbar Electric 230-50-3 L1 L2 L3 Ground to PE Busbar Electric 380-50-3 L1 L2 L3 Ground to PE Busbar Electric 415-50-3 L1 L2 L3 Ground to PE Busbar Figure 4 GAS DRYING TUMBLERS GAS DRYING TUMBLERS Minimum Wire Size 240V, 1 Phase, 50 Hz.
ELECTRICAL REQUIREMENTS For 30 Pound (13 kg) Tumblers REQUIREMENTS Heat Source Electrical Specs Wires Required and Terminal Block Connection Gas & Steam 230/50/1 L1 L2 Ground to PE Busbar Electric 230/50/1 L1 L2 Ground to PE Busbar Electric 380/50/3 L1 L2 L3 Ground to PE Busbar Electric 415/50/3 L1 L2 L3 Ground to PE Busbar Steam 380/50/3 L1 L2 L3 Ground to PE Busbar Figure 7 GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS Minimum Wire
30 Pound (13 kg) Tumblers LOW STEAM DRYING TUMBLERS LOW PRESSURE STEAM DRYING TUMBLERS 240 V, 1 Phase 50 Hz. Minimum Wire Size 16 AWG (1.309 mm²) Circuit Breaker 20 AMP Poles 2 Figure 10 GROUNDING INSTRUCTIONS Drying tumbler must be grounded. In event of malfunction or breakdown, grounding will reduce risk of electric shock by providing a path of least resistance for electric current.
ELECTRICAL REQUIREMENTS For 50 Pound (22 kg) Tumblers REQUIREMENTS Heat Source Electrical Specs Wires Required and Terminal Block Connection Non-Reversing Models Gas & Steam 230/50/1 L1 L2 Ground to PE Busbar Steam 380-415/50/3 L1 L2 Electric 230/50/1 L1 L2 Electric 380-415/50/3 L1 L2 Gas & Steam 230/50/1 L1 L2 Gas & Steam 380-415/50/3 L1 L2 L3 Ground to PE Busbar Electric 230/50/3 L1 L2 L3 Ground to PE Busbar Electric 380-415/50/3 L1 L2 L3 Ground to PE Busbar L3 G
50 Pound (22 kg) Tumblers LOW PRESSURE STEAM DRYING TUMBLERS LOW PRESSURE STEAM DRYING TUMBLERS 240 V 1 Phase, 50 Hz. Minimum Wire Size 14 AWG (2.081 mm²) Circuit Breaker 15 AMP Poles 2 Figure 14 GROUNDING INSTRUCTIONS Drying tumbler must be grounded. In event of malfunction or breakdown, grounding will reduce risk of electric shock by providing a path of least resistance for electric current.
ELECTRICAL REQUIREMENTS For 75 Pound (34 kg) Tumblers REQUIREMENTS Heat Source Electrical Specs Gas & Steam Wires Required and Terminal Block Connection 230/50/1 L1 L2 Ground to PE Busbar Electric 208-230/50-60/3 L1 L2 L3 Ground to PE Busbar Electric 380/50/3 L1 L2 L3 Ground to PE Busbar Electric 415/50/3 L1 L2 L3 Ground to PE Busbar Steam 380/50/3 L1 L2 L3 Ground to PE Busbar Figure 15 GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS
ELECTRICAL CONNECTIONS 維 WARNING DISCONNECT SWITCH JUNCTION BOX COVER All electrical connections should be made by a qualified electrician. To reduce the risk of electrical shock, de-energize the electrical circuit being connected to the tumbler before making any electrical connections. Never attempt to connect a live circuit. NAMEPLATE Use the following steps to connect electrical service to the tumbler: GUARD 1. Install a circuit breaker, as close to tumbler as possible.
POSITIONING DRYING TUMBLER Screw four leveling legs back into level adjusting fittings from top. Slide tumbler to its permanent location and level. Keep tumbler as close to floor as possible. All four legs must rest firmly on floor so weight of tumbler is evenly distributed. Tumbler must not rock. Tumbler may be removed from skid before moving to installation location or moved while still attached to skid.
Example of Gas Loop Piping IMPORTANT: Gas loop piping must be installed as illustrated to equalize gas pressure for all tumblers connected to single gas service. Other gas using appliances should be connected upstream from loop. GAS SPACE HEATER MAIN REGULATOR TUMBLERS GAS SHUT-OFF VALVES GAS LINE PRESSURE TAP GAS METER GAS WATER HEATERS ONE INCH (2.54 cm) PIPE GAS LOOP NOTE: Minimum pipe size to tumbler is 1/2" (1.
GAS PIPE SIZE REQUIRED FOR 1,000 BTU NATURAL GAS — .64 SPECIFIC GRAVITY AT 6½ ± 1½ INCH WATER COLUMN PRESSURE (1.62 ± .37 kPa) EQUIVALENT LENGTH GAS APPLIANCES TOTAL BTU/HR. (Kcal/hr) 25 FT. (7.63 m) 50 FT. (15.25 m) 75 FT. (22.88 m) 100 FT. (30.50 m) 125 FT. (38.13 m) 150 FT. (45.75 m) BASED ON 0.3" WATER COLUMN (0.75 mBar) PRESSURE DROP FOR LENGTH GIVEN 100,000 (25,200) ³⁄₄" (1.905cm) ³⁄₄" (1.905cm) 1" (2.54cm) 1" (2.54cm) 1" (2.54cm) 1" (2.54cm) 120,000 (30,240) ³⁄₄" (1.905cm) 1" (2.
GAS CONNECTIONS (Gas Drying Tumblers) Before connecting gas piping to tumbler, make certain gas service is same as that specified on nameplate (near gas connection), Page 5. Purge air and sediment from gas service line before connecting it loosely to tumbler. Purge remaining air until odor of gas is detected, then tighten connection. Use pipe compound, resistant to actions of L.P. gas, on all pipe threads. NATURAL GAS service must be supplied at 6¹⁄₂ ± 1¹⁄₂ inch water column pressure (1.62 ± .37 kPa).
DRYING TUMBLER ENCLOSURE CONSTRUCTION 維 WARNING IMPORTANT: DO NOT block airflow at top rear of tumbler with laundry, etc. Doing so would prevent adequate air supply to tumbler’s heat chamber. To reduce the risk of serious injury, install lockable doors to prevent public access to rear of tumblers. A typical tumbler enclosure is shown in Figure 23. Note that enclosure does touch tumbler top and side panels. Note, too, minimum and maximum dimensions.
STEAM REQUIREMENTS (Steam Drying Tumblers) information should be obtained from the steam system supplier or a qualified steam fitter. Size of steam service pipe is dependent upon many variables (length, tees, high pressure system, low pressure system, etc.
STEAM CONNECTIONS (Steam Drying Tumblers) NOTE: See Figure 25 for sizing of steam lines. Piping must also be sized accordingly for length of runs, and number of elbows. 30.
LIGHTING AND SHUTTING DOWN GAS IGNITION SYSTEM during first three seconds ignition control will “lockout” causing gas valve to close and a red button on ignition control to illuminate. 1. Turn machine disconnect switch, located on rear of tumbler, to the “on” position. To reset ignition system , open access door and press red button on ignition control. Close and lock access door, verify that gas shut-off valve is in the “on” position and return to step three. 2.
ACCESSORY TIMING CAM INSTALLATION (Coin Meter Models) REMOVAL OF EXISTING TIMING CAM No. of Pins in Cam Cycle Length (Minutes) 6 5 4 10 12 15 1. Rotate cam by hand until "V" notch lines up beneath the ratchet tooth see Figure 28. 2. Insert narrow screwdriver under nylon cam, close to the clock shaft. Lift gently off shaft. Make sure that pressure is directed upward and that the "V" notch clears the ratchet tooth. Figure 27 Cams that allow other timer increments are available through your distributor.
PRELIMINARY OPERATING CHECKS 1. Remove or open all panels and inspect accessible bolts, nuts, screws, terminals and fittings for security. 6. Load tumbler with clothes or clean rags. 7. Start tumbler and check burner flame, adjust gas inlet shutter if necessary (refer to Adjustment Section). 2. Check belt tension, adjust if necessary (refer to Adjustment Section). 8. Check air flow switch operation by opening lint panel. Heating system should shut off when lint panel is opened approximately 1-1/2" (3.
NOTES 52 M412616
SECTION III Adjustments MAIN GAS BURNER AIR SHUTTER (All Gas Models) 5. After air shutter is adjusted for proper flame, tighten air shutter adjusting screw securely. Control panel may have to be removed temporarily to loosen air shutter screws to turn shutter. NOTICE: Both air inlet shutters on burner must be adjusted so sufficient air is metered into system for proper combustion and maximum efficiency. Before adjusting inlet shutters be sure that all lint is removed from lint compartment and lint screen.
Electric Models: If switch remains open, or pops open and closed during cycle, heating system will shut off. Cylinder and fan will continue to operate even though air flow switch is malfunctioning. Counterweight should be adjusted so air flow will force disc away from cabinet when lint panel is opened 6 inches (15.24 cm) with a full load. Adjust air flow switch as follows: 1. Load tumbler. Gas Models: If switch remains open, entire unit will shut down when Push-to-start button is released.
LOADING DOOR SWITCH CYLINDER DOOR STRIKE Loading door switch turns off tumbler any time loading door is opened. To adjust loading door switch, follow these steps: The door strike must be adjusted to have sufficient tension to hold loading door closed against force of load tumbling against it. Proper adjustment is when 8 to 15 pounds (35.6 N - 66.7 N) pull is required to open door. 1. Start tumbler following operating instructions which accompanied it.
DRIVE V-BELT 維 WARNING To reduce the risk of serious injury or death, disconnect power to the tumbler before performing this operation. Proper tension is when belt can be depressed approximately ¹⁄₂ inch (1.27 cm) by applying light thumb pressure at a point midway between the sheave and motor pulley. 1. Remove guard from rear of tumbler. 2. To adjust belt tension, loosen adjusting bolt holding idler housing assembly to housing support. 3. To a. b. c. tighten V-belt: Loosen lower nut on adjusting bolt.
SECTION IV Preventive Maintenance Instructions DAILY 6. Ensure lint screen covers entire opening in lint screen hood. Gaps between lint screen and lint screen hood allows lint to flow into ductwork system restricting air circulation. 1. Make certain drying cycle has ended. 2. Open loading door. 3. Unlock and remove lint panel. 7. Wipe any accumulated lint off thermostat sensing probe. Lint buildup on sensing probe will cause overheating of tumbler. 4. Remove accumulated lint in lint compartment.
Quarterly 1. Deactivate electrical circuit by turning off disconnect switch on rear of tumbler. 6. Remove screws holding rear drive guard to back of tumbler. 2. Perform daily cleaning of accumulated lint. 7. Inspect belts for wear and proper tension (refer to Adjustments section). 3. Perform monthly inspection and cleaning of accumulated lint. 8. Reinstall rear drive guard to back of tumbler. 4. Clean accumulated lint and other debris from front and back motor air vents. 9.
QUARTERLY MAINTENANCE (DATES) Clean air vents on drive motor. Check and clean steam coils. (Steam Models Only) Clean exhaust ducts. Check flow of combustion air. Check flow of ventilation air. Check belt tension. Check chain tension. BIANNUAL MAINTENANCE (DATES) Check for loose nuts. Check for loose bolts. Check for loose screws. Check for loose gas connections. Check for loose electrical connections. Check for loose steam connections. (Steam Models Only.
NOTES 60 M412616
SECTION V Decommissioning Instructions 1. Turn off electrical supply external to machine. 2. Turn off electrical disconnect on machine. 3. Turn off gas supply external to machine. 4. Turn off manual gas shut-off valve on machine. 5. Turn off steam supply external to machine. 6. Remove all electric, gas and steam connections.