Horizontal Exhaust Installation: Exhaust Air Flow Maximum Length of Duct 9.1 m [30 feet]
D686I_SVG
8
6
5
7
A B C D E F G H I J K
9
3
2
4
1
1. Where the exhaust duct pierces a combustible wall or ceiling, the opening must be sized per local codes.
2. Wall
3. 50 mm [2 in.] Minimum or Clearance per Local Codes
4. No Screen or Cap
5. 610 mm [24 in.] Minimum Clearance to Roof/Ground
6. Exhaust Outlet
7. Air Flow
8. 30 °
9. Clean Out Cover - Inspect Monthly
Figure 7
Duct Station
Minimum Diameter of
Collector Duct
A 102 mm [4 inches]
B 203 mm [8 inches]
C 229 mm [9 inches]
D 254 mm [10 inches]
E 279 mm [11 inches]
F 305 mm [12 inches]
G 326 mm [13 inches]
H 356 mm [14 inches]
I 381 mm [15 inches]
J 381 mm [15 inches]
K 406 mm [16 inches]
Table 3
Installation
©