Owner Manual

Four-Wire Connection
D680I_SVG
1
2
1
9
8
7
6
5
4
3
1. Ground Wire
2. Ground Screw
3. “L1” Terminal
4. Neutral Terminal
5. “L2” Terminal
6. Black Wire
7. White Wire (Neutral)
8. Strain Relief (Not supplied with dryer)
9. Red Wire
Figure 12
NOTE: Dryer is shown with access cover removed for
illustration purposes only. NEVER operate the dryer
with access cover removed.
Connecting Power Cord with Three-Wire Plug
NOTE: Four-wire cord is required for new branch-cir-
cuit installations, mobile homes or where codes do not
permit grounding through neutral.
NOTE: The power cord is NOT supplied with the elec-
tric dryer. Type of power cord and gauge of wire must
conform to local codes and instructions. The method
of wiring the dryer is optional and subject to local code
requirements.
NOTE: Connect the dryer to the power supply with the
MAXIMUM RATED VOLTAGE listed on the serial plate.
NOTE: Use COPPER WIRE only.
Shorter than 15 ft. (4.5 m) – use 10 AWG
Longer than 15 ft. (4.5 m) – use 8 AWG
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
23 Part No. D514691ENR8