Installation Instructions
Table Of Contents
- Table of Contents
- Dimensions
- Installation
- Before You Start
- Position Unit Near Installation Area
- Remove Shipping Materials
- Connect Fill Hoses
- Connect Drain Hose to Drain Receptacle
- Gas Dryers - Connect Gas Supply Pipe
- Electric Dryer Only - Connect Electrical Plug
- Connect Dryer Exhaust System
- Position and Level the Unit
- Reverse Door, if Desired
- Wipe Out Inside of Washer and Dryer Drum
- Plug In the Washer and Dryer
- Check Installation
- Check Heat Source
- Installer Checklist
Gas Dryers
IMPORTANT: This operation is to be conducted by
qualified personnel only.
1. To view the burner flame, remove the lower front panel of the
dryer.
2. Close the loading door and start the dryer in a heat setting (re-
fer to the operation instructions). The dryer will start, the ig-
niter will glow red and the main burner will ignite.
IMPORTANT: If all air is not purged out of gas line,
gas igniter may go off before gas is ignited. If this
happens, after approximately two minutes igniter
will again attempt gas ignition.
IMPORTANT: If igniter does not light, make sure gas
is turned on.
3. After the dryer has operated for approximately five minutes,
observe burner flame through lower front panel.
4. Adjust the air shutter to obtain a soft, uniform blue flame. (A
lazy, yellow-tipped flame indicates lack of air. A harsh, roar-
ing, very blue flame indicates too much air.) Adjust the air
shutter as follows:
a. Loosen the air shutter lockscrew.
b. Turn the air shutter to the left to get a luminous yellow-
tipped flame, then turn it back slowly to the right to obtain
a steady, soft blue flame.
c. After the air shutter is adjusted for proper flame, tighten
the air shutter lockscrew securely.
5. Reinstall the lower front panel.
WARNING
To reduce the risk of serious injury or death, low-
er front panel must be in place during normal op-
eration.
W158
6. After the dryer has operated for approximately three minutes,
exhaust air or exhaust pipe should be warm.
D702I_SVG2
4
1
2
3
1.
Air Shutter Lockscrew
2. Air Shutter
3. Appliance Main Gas Valve
4. 3.1 mm [1/8 in.] Pipe Plug (For checking manifold pres-
sure)
Figure 37
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
29 Part No. 807638EN