1. Injection Point
2. Nozzle
3. Supply Dispenser Pump Outlet
Figure 13
A junction box on the rear panel houses a terminal strip which
furnishes supply output signals for the supply injection pumps.
These are dry contacts. Voltage needs to be supplied. Refer to the
chemical injection electrical interface label.
804607R1
CHEMICAL INJECTION ELECTRICAL INTERFACE
1
5
6
9
5
3
7
2
6
24 V AC RETURN
24 VAC RETURN
IF NOT WIRING TO INTERNAL
24 VAC SUPPLY DISCONNECT
TRANSFORMER WIRES FROM
TERMINALS 5 AND 6 AND CAP
THE WIRES. SEE EXPANSION
OPTION DIAGRAM FOR
ALTERNATE CONNECTION DETAILS.
EXAMPLE FOR EXTERNAL SUPPLY CONNECTION
(FOR PROVIDED 24 VAC ONLY)
EXTERNAL
SUPPLY
SYSTEM
24 VAC RETURN
24 VAC
4
8
9
1
FLW2377N_SVG
Figure 14
These terminals may be used to provide signals to the supply in-
jection system but must not be used to provide power to the ac-
tual pump.
Any injection system pump which requires 110 VAC must be
powered by a separate external power source.
Control Function Test
The washer should be cleaned after the installation is complete. A
function test should then be executed on the unloaded machine:
1. Check the power supply for such characteristics as correct
voltage, phase, and cycles to be certain they are correct for the
washer.
2. Open manual shut-off valves to the washer.
3. Apply power to the washer.
Plug In the Washer
Electrical Requirements
120 Volt, 60 Hertz with 3-Prong Earth/Ground Plug
NOTE: The wiring diagram is located in the control cab-
inet.
WARNING
To reduce the risk of fire, electric shock, serious in-
jury or death, all wiring and protective earth/ground
connections MUST conform with the latest edition of
the National Electrical Code, ANSI/NFPA No. 70, and
such local regulations as might apply. It is the cus-
tomer’s responsibility to have the wiring, fuses and
circuit breakers installed by a qualified electrician to
make sure adequate electrical power is available to
the washer.
W824
When plugging in the washer:
• DO NOT overload circuits.
• DO NOT use an extension cord.
• DO NOT use an adapter.
• DO NOT operate other appliances on the same circuit. Use
separately fused 15 Amp circuits.
The washer is designed to be operated on a separate branch, po-
larized, three-wire, effective earth/ground, 120 Volt, 60 Hertz,
AC (alternating current), circuit protected by a 15 ampere fuse,
equivalent fusetron or circuit breaker.
The three-prong earth/ground plug on the power cord should be
plugged directly into a polarized three-slot effective earth/ground
receptacle rated 110/120 Volts AC (alternating current) 15 Amps.
Refer to Figure 15 to determine correct polarity of the wall recep-
tacle.