GUIDE SPECIFICATIONS & FEATURES
Part 1- General Part 3- Features
1.01 Summary
A. This section includes application for both 3.01 Rigid Frame
Residential and Commercial installations to. 22 Ga. (7mm) G90 galvanized rigid steel frame provides a sturdy
1. Floor installations base frame and solid Register/Grille backing for set screw
2. Wall installations installation. Pre-Piloted holes provides easy and level Register
3. Ceiling installations Grille installations. Sizes 1212 and larger are ¼” larger than stated size.
1.02 Submittals 3.02 Adjustable Sliding Brackets
A. Prepare and submit for approval information 22 Ga. (7mm) G90 galvanized rigid steel telescoping arm
as required by the conditions of the contract and extension capability allows for both 16” and 24” Joist/Truss
division 1 Submittals Section. span application. Precise installation in either parallel, transverse,
horizontal or vertical positions. Reduced risk of injury from
B. Submit product data for each Speedi-Boot Model custom wood and metal framing.
size specified.
3.03 Air Tight Installation
Closed cell rubber gasket provides an Air Tight Seal interface
1.03 Quality Assurance with Floor, Wall or Ceiling significantly reducing air Leakage
A. Installers shall be qualified to perform work of and increases energy efficiency of Boot installations. Duct
this section and shall be experienced in the perform- pressure testing may be accomplished with Dust and Debris
ance of installation operations as appropriate to Cover in place prior to wall board installation to identify leak
the project. Points if any prior to duct system covering.
1.04 Delivery and Storage 3.04 Dust and Debris Cover
A. Deliver all Speedi-Boots to the project site in Provided Dust and Debris Cover prevents construction debris
Manufacturers original unopened, undamaged from contaminating duct system during construction phase of
packaging. Store in a safe place protected from project providing a clean healthy duct system.
moisture, and physical damage before and during
installation.
Part 2- Execution Solid Mud-Ring eliminates boot deformation and accidental
Boot covering during drywall installation. Ensures consistent
2.01 Inspection dimensions for Register/Grille installation.
A. Verify that all Speedi-Boots to be installed in
accordance with project drawings, specifications
and local codes. 3.06 Wood-Metal Stud Applications
B. Confirm that all necessary wall, partition and Telescoping Arms provided with Pre-Attached nails for Wood
floor/ceiling assembly construction has been construction and pre-piloted holes for Metal construction projects.
completed to the point where the installation may
be correctly installed.
2.02 Installation 3.07 Multi Size Capability
A. Install in compliance with manufacturers Fits most universal Ceiling, Wall and Floor boots and duct sizes.
instructions and good workmanship so that the multiple sizes for most common sizes utilized for both Supply
performance requirements are met. and Return Air Boots and Ducts.
2.03 Safety Precautions 3.08 Improved Indoor Air Quality
A. Conduct all job site operations in compliance Sealed gasket prevents unwanted air infiltration from unwanted
with applicable provisions of the Occupational areas such as crawl spaces, attics and unfinished basements which
Safety and Health Act and/or Safety and Health may harbor unwanted Molds, Mildews, Allergenic or Toxilogical
Codes and Regulations. Sources.