Instruction manual

34 SPEKTRUM DX7 • TRANSMITTER INSTRUCTION MANUAL
EN
Back Mixing applies a mix to all related servos in a wing or tail
type. For example, if you select 2 AIL, 2 FLAP in the Aircraft Type
screen, a mix to one aileron channel affects both aileron servos.
The mix response, however, depends on the aileron channel
included in the mix.
A Back Mix also enables you to use fewer mixes to achieve the
desired response, for example adding roll to a split elevator.
The Range Test function reduces the power output. This allows for
a range test to confi rm the RF link is operating correctly. Perform
a range check at the beginning of each fl ying session to confi rm
system operation.
To Access the Range Test screen:
1. With the transmitter on and the main or telemetry screen
displayed, press the scroll wheel. The Function list displays.
2. Scroll to highlight Range Test, then press the scroll wheel to
access the Range Test function.
3. With the Range Test screen displayed, push and hold the
trainer button. The screen displays Reduced Power. In this
mode the RF output is reduced allowing for an operational
range test of your system.
4. If you let go of the trainer button, the transmitter will go back
to Full Power.
IMPORTANT: Telemetry alarms are disabled during the
Range Test.
Range Testing the DX7
1. With the model restrained on the ground, stand 30 paces
(approx. 90 feet/28 meters) away from the model.
2. Face the model with the transmitter in your normal fl ying
position and place the transmitter into Range Test mode (see
above). Then push the trainer button; the power output will be
reduced.
3. Operate the controls. You should have total control of your
model with the transmitter in Range Test mode.
4. If control issues occur, contact the appropriate Horizon Product
Support offi ce for assistance.
5. If performing a range test while a telemetry module is active,
the display will show fl ight log data.
The DX7 Timer function allows you to program a countdown timer
or stop watch (count up timer) to display on the main screen. An
alarm sounds when the programmed time is reached. You can
program the timer to start using the assigned switch position or
automatically when throttle is raised above a programmed position.
Two internal timers are available that show run time for a specifi c
model displays on the Main Screen. A total system timer is also
available.
Press NEXT to select the Timer Event Alerts settings. These
include options for the alerts at every minute for down timers, 1
minute remaining alert, 30 seconds remaining alert, 10 second
to 1 second remining alerts, expiration alert, and every minute up
alert. Press NEXT again to select the Timer Control Alerts settings.
Available options include Timer Start alert, Timer Stop alert, and
Timer Reset alert.
FUNCTION LIST
Back Mixing
Range Test
Timer
Timer Event and Timer Control Alerts