8
if in the 2nd time. pressing for 2 seconds, it will enter directly into the
“LIGHT” status, and the LCD backlight light up. After 15 seconds, the
backlight is shut off automatically, the same as pressing for 2
seconds within 15s.
b) Display Indicators
The Primary Display:Indicate the current function testing values
The Secondary Display: It shows the output DCV while you test the
insulation resistance, and the battery voltage while the ACV
The Analog Bar : indicate the current function testing value in
synchronous with the primary display.
:While testing the insulation resistance, the symbol
“ “ flashes frequently if the voltage is over 30V.
•))) : While testing the insulation resistance, the symbol” •)))
“ flashes frequently and the buzzer warns continually if the
outside voltage is over 30V. the symbol “
•))) “ is indicated
while
LOΩ≤35Ω and the BZ warns continuously.
LOCK:
:
Push down the “LOCK” button while you test the insulation
resistance and the symbol “
” is indicated.
LOBAT:The display shows “LOBAT” when the voltage
drops below 7.5V
MAX/MIN:Stand for the maximum or the minimum.
ZERO : Digital zero adjusting。
HOLD :The digital holding function for the primary display.
AC,
,
DC,
,
:The indicator for the voltage property.
V,
,
MΩ,
,