Operation Manual

GB
11
CHAPTER 1 - INTRODUCTION
1.1 GENERAL SAFETY INSTRUCTIONS
Warnings for the safety of individuals and objects.
Carefully follow the instructions marked with the following symbols.
DANGER
Warns that the failure to follow the directions given could
cause serious risk to individuals or objects.
DANGER
Electric shock risk
Warns that the failure to follow the directions given may
cause electric shock.
WARNING
Warns that the failure to follow the directions given could
damage the electropumps.
WARNING: Read this manual carefully before installing this pump. Any damage caused by failure to
observe the directions contained in this m anual will not be covered by warranty.
1.2 GENERAL INFORMATION
Series CXM comprises single-bloc centrifugal electropumps, wi thout self-priming device, with front
suction, radial delivery and with 1 stage. Every electropump is carefully tested and packed during its
assembly.
1.3 PRELIMINARY CHECKS
WARNING
Always keep the original packaging for possible future
transport of the machine.
• Check the packaging is intact
• Open the packaging and remove the machine
• Check the machine corresponds to that ordered
• Check the machine is not damaged
• If you receive an incorrect or damaged machine, notify the authorised dealer within and not
after 10 (ten) days from date of purchase
CHAPTER 2 - TECHNICAL FEATURES
DANGER
Do not use the product in environments with acid,
corrosive and/or inammable gas
Do not use the motor pump with dangerous liquids.
2.1 LIMITATIONS
• Ambient temperature: +0°C to + 40°C
• Maximum temperature of liquid: 90 °C
• Level of protection: IP55
• Maximum operating pressure: 8 bar
• Power voltage: 1x230 Vac ± 10 % - 3x230/400 Vac ± 10 %
• Inbound frequency: 50 Hz + 3%
• Maximum suction height: 7 mt with standing valve (recommended)