Users Manual Part 3

HDE 07.09.2020 732.22.110
40
7. Clearing locking authorisations
7.1 Erasing the locking authorisation of an individual user key
Prerequisites: Clearing key card
User key with locking
authorisation to be cleared
1. Hold the clearing key card in front of the
antenna.
Acoustic signal is heard. LED flashes red for
max. 5 seconds.
2. Hold the user key in front of the antenna during
this 5-second period.
Acoustic signal is heard. LED briefly
illuminates red. Locking authorisation of this
user key is cleared.
Tag-it ™ISO
x
5 s
1 s