Users Manual Part 3

HDE 07.09.2020 732.22.110
44
8.3 Adjusting the open time
Prerequisites: Programming key card Clearing key card
1. Hold the programming key card in front of the
antenna.
Acoustic signal is heard. LED illuminates
green.
2. Hold the clearing key card in front of the
antenna.
Acoustic signal is heard. The LED flashes
quickly in green.
3. Hold the clearing key card in front of the
antenna again.
An acoustic signal is heard at one second
intervals.
The LED flashes green in parallel to the
acoustic signal every second (max. 30
seconds).
4. Remove clearing key card after the required
time.
The LED illuminates permanently in red.
The open time is set for all locks and
authorised user keys.
The open time can be adjusted at any time, and is also retained after a power supply
interruption or a simple reset.
The open time can be extended to beyond 30 seconds using a macro with the
MDU 110 mobile programming unit with special functions (
3.2 Technical data, page
31).
After a complete reset, the set open time is cleared and the factory setting of 3
seconds or deadbolt lock operation are activated.
Tag-it ™ISO
Tag-it ™ISO
x
1x/s 1x/s
ins-src-732.22.110_EFL.book Seite 44 Donnerstag, 8. Oktober 2020 8:22 08