User's Manual

SmartCloud Radio Node - SCRN 200 Hardware Installation Guide
SpiderCloud Wireless, Inc.
11
Select the Radio Node Location
Select a location for the radio node. The unit can be installed in a wide range of locations including walls,
ceilings, and plenum spaces. Follow the installation guidelines for choosing appropriate mounting locations
for the unit. When mounting a radio node vertically, align the fins vertically for superior cooling.
Figure 7 Radio Node Locations
Locate radio node units at least 5 meters (16 feet) from an external wall. This distance maximizes indoor
coverage and minimizes RF leakage outside the building.
Use Table 2 to determine the maximum distance between radio node units. Greater separation may affect
coverage or system performance.
Table 2: Recommended Radio Node Separation Distances
Type of Building Max Recommended Separation
Warehouses and large open-spaced buildings 70 m (230 feet)
Open-plan offices 45 m (148 feet)
Closed-plan offices (e.g., individual rooms - plasterboard) 30 m (98 feet)
Closed-plan offices (e.g., individual rooms - stone/brick/concrete) 20 m (66 feet)
Dead / Non-Circulating
Airspace
Living / Working Space of a Typical
Commercial Building
Drop Ceiling
Wall
Forced-Air Supply
Forced-Air Return
X
X