User's Manual Part 2

Nomad User’s Manual Chapter 9 Voice Quality Configuration Options
Copyright © Spirent Communications, Inc. 2013 123
9.7 Base Station Simulator Testing
The Rohde & Schwarz CMU200 and the Agilent 8690 are two commercial base station simulators
commonly used to simulate radio conditions in a test lab. An optional Nomad upgrade provides the
cables required to interface to these pieces of equipment for degraded channel, noise cancellation
and other test scenarios. This interface allows the test handset to perform both sourcing and
recording functions, enabling handset testing without a landline voice server. Please contact your
Spirent Communications representative for additional information on this option.
To configure Nomad to work with a base station simulator:
Load the desired test conditions into the simulator. Please see the manufacturer’s
documentation for simulator configuration details.
Connect the test handset to Channel 1 on the Spirent ME hardware unit or NB1/HB1 on the
Spirent HD ME Unit.
Connect the audio cable provided by Spirent Communications from the base station
simulator to Channel 2 on the Spirent ME hardware unit or NB2/HB2 on the Spirent HD
ME Unit.
Figure 9-7 - Base Station Simulator Hardware Configuration
On the Nomad Test Setup screen, configure Channel 1 as a Mobile task with the following
setting:
o Session Uplink Device: Base task on channel 2
On the Nomad Test Setup screen, configure Channel 2 as a Base task with the following
settings:
o Session Downlink Device: Mobile task on channel 1
o Channel Settings Input: 205
o Channel Settings Output: 195
Confirm that both test channels use the same Scoring Model. Both channels must be set for
either PESQ or POLQA in the Session dialog.