May 2011 / Catalog 201 Catalog 201 Condensed Catalog of Sporlan Products ®
Page 2 — CATALOG 201 t CONDENSED CATALOG 201 This catalog is a condensed version of the complete Sporlan Catalog. By including a minimum of engineering information we are able to provide a concise reference to pertinent data and specifications on Sporlan products. MAY 2011 For additional engineering information, a complete Sporlan Catalog or CD, please contact your nearest Sporlan Sales Office, Authorized Sporlan Wholesaler or log on to www.sporlan.com.
CATALOG 201 — Page 3 t THERMOSTATIC EXPANSION VALVES (TEV) Valve Nomenclature / Ordering Instructions EXAMPLE EG Body Type F = E = V = G = M= J = X = L = S = V E Sporlan Code – Refrigerant Element Label Color Code “E” specifies external equalizer. Omission of letter “E” indicates valve with internal equalizer. e.g. EGV-1-C R-12 Yellow R-13 Blue R-22 Green R-23 Blue R-124 Blue R-134a Blue R-401A Pink R-402A Sand R-404A Orange V = R -407A Green N = R -407C Lt.
Page 4 — CATALOG 201 t TEV CAPACITIES - TONS 22, 422D, 407C AIR CONDITIONING, HEAT PUMP and COMMERCIAL REFRIGERATION APPLICATIONS REFRIGERANT 422DQ 407C RECOMMENDED THERMOSTATIC CHARGE NOMINAL VALVE TYPES CAPACITY VC, VCP100, VGA VZ, VZP40 VC, VCP100, VGA VZ, VZP40 NC, NCP100, NGA EVAPORATOR TEMPERATURE °F 40° 20° 0° -10° -20° -40° 40° 20° 0° -10° -20° -40° 40° 20° 0° F-EF-G-EG 1/5 0.20 0.22 0.19 0.17 0.15 0.11 0.14 0.15 0.13 0.11 0.10 0.07 0.18 0.20 0.17 F-EF-G-EG 1/3 0.35 0.38 0.33 0.27 0.24 0.18 0.
CATALOG 201 — Page 5 tTHERMOSTATIC TEV CAPACITIES - TONS VALVES EXPANSION 22, 422D, 407C AIR CONDITIONING and HEAT PUMP APPLICATIONS VALVE TYPES NOMINAL CAPACITY R, RC R, RC R, RC R, RC R, RC R, RC R, RC R R R RIVE E RIVE E RIVE E RIVE E 1 1-1/2 2 3 4 5 6 8 10 12 2 3 4 5 REFRIGERANT 0° 10° 22 422D 407C 1.56 1.99 1.69 1.51 1.90 1.62 EVAPORATOR TEMPERATURE °F 40° 20° & 0° 22 40° 1.0 1.8 2.3 3.2 4.2 5.0 6.0 8.0 10.4 12.1 2.1 3.4 4.2 4.5 20° 1.1 1.9 2.5 3.5 4.6 5.5 6.5 8.7 11.4 13.2 2.3 3.7 4.
Page 6 — CATALOG 201 t TEV CAPACITIES - TONS 404A, 408A COMMERCIAL and LOW TEMPERATURE REFRIGERATION APPLICATIONS 404A REFRIGERANT 408A RECOMMENDED THERMOSTATIC CHARGE VALVE TYPES SC, SCP115 SZ, SZP SC, SCP115 SZ, SZP EVAPORATOR TEMPERATURE °F 40° 20° 0° -10° -20° -40° 40° 20° 0° -10° -20° F-EF-G-EG 1/8 0.15 0.16 0.15 0.15 0.13 0.11 0.20 0.21 0.20 0.22 0.19 F-EF-G-EG 1/6 0.23 0.24 0.23 0.24 0.21 0.17 0.31 0.33 0.32 0.34 0.30 F-EF-G-EG 1/4 0.29 0.31 0.29 0.31 0.27 0.22 0.39 0.42 0.41 0.43 0.
CATALOG 201 — Page 7 tTHERMOSTATIC TEV CAPACITIES - TONS VALVES EXPANSION 402A, 507 COMMERCIAL and LOW TEMPERATURE REFRIGERATION APPLICATIONS 402A REFRIGERANT 507 RECOMMENDED THERMOSTATIC CHARGE VALVE TYPES LC LZ, LZP PC PZ, PZP EVAPORATOR TEMPERATURE °F 40° 20° 0° -10° -20° -40° 40° 20° 0° -10° -20° F-EF-G-EG 1/8 0.15 0.16 0.15 0.16 0.13 0.11 0.14 0.15 0.14 0.15 0.13 F-EF-G-EG 1/6 0.23 0.24 0.23 0.24 0.21 0.18 0.22 0.24 0.22 0.24 0.20 F-EF-G-EG 1/4 0.29 0.31 0.29 0.31 0.27 0.23 0.29 0.30 0.29 0.30 0.
Page 8 — CATALOG 201 t TEV CAPACITIES - TONS 134a, 401A, 409A AIR CONDITIONING, HEAT PUMP and COMMERCIAL REFRIGERATION APPLICATIONS REFRIGERANT 401A 409A RECOMMENDED THERMOSTATIC CHARGE NOMINAL VALVE TYPES CAPACITY JC, JCP60 XC, XCP60 FC, FCP60 EVAPORATOR TEMPERATURE °F 40° 20° 0° 40° 20° 0° 40° 20° 0° F-EF-G-EG 1/8 0.15 0.15 0.14 0.16 0.16 0.15 0.15 0.15 0.14 F-EF-G-EG 1/6 0.25 0.28 0.26 0.27 0.30 0.29 0.25 0.28 0.27 F-EF-G-EG 1/4 0.31 0.35 0.33 0.34 0.37 0.36 0.32 0.35 0.33 F-EF-G-EG 1/2 0.60 0.60 0.
CATALOG 201 — Page 9 t TEV QUICK REFERENCE GUIDE NOMINAL CAPACITY RANGE (Tons) VALVE TYPE SPECS R-22 R-134a R-404A & R-507 R-410A CONNECTION TYPES VALVE DESCRIPTION AND APPLICATION Chatleff, SAE Flare, or ODF Solder Small brass body, externally adjustable valve available for R-22 and R-410A air conditioning and heat pump applications.
Page 10 — CATALOG 201 t TEV QUICK REFERENCE GUIDE NOMINAL CAPACITY RANGE (Tons) VALVE TYPE SPECS CONNECTION TYPES VALVE DESCRIPTION AND APPLICATION Extended ODF Solder Type SQ same as the Type Q valve except it features ODF solder connections and a forged brass inlet fitting with a removable 100 mesh strainer screen which can be cleaned and/or replaced without removing the valve from the line.
CATALOG 201 — Page 11 t TEV QUICK REFERENCE GUIDE NOMINAL CAPACITY RANGE (Tons) VALVE TYPE SPECS R-22 R-134a R-404A & R-507 Page 25 8 thru 20 5 thru 12 6 thru 13 – Page 26-27 15 thru 70 9 thru 40 9 thru 45 20 thru 60 R-410A CONNECTION TYPES VALVE DESCRIPTION AND APPLICATION Extended ODF Solder Same physical size and inlet strainer as the Type S valve except it features extended ODF connections.
Page 12 — CATALOG 201 t TYPE RC For Refrigerants 22, 410A Chatleff, SAE Flare & ODF Solder Connections Sporlan Type RC valve is a small brass body, externally adjustable valve with balanced port construction. The RC valves are available for replacement of types CBI and CBBI valves. These valves contain internal check valves to allow reverse flow on heat pump applications. This eliminates the need for an external check valve piped around the TEV for reverse flow.
CATALOG 201 — Page 13 t TYPE ER For Refrigerants 22, 410A ODF Solder Connections Sporlan Type ER valve is a small brass bar body, externally adjustable with ODF solder connections, a replaceable thermostatic element, and balanced port construction. The R valve is designed for R-22 and R-410A air conditioning and heat pump applications and is ideal for replacing I, BI, BBI and RI (non-RPB version only) valves.
Page 14 — CATALOG 201 t TYPE ER For Refrigerant 22, 410A ODF Solder Connections TYPE ER with NUMBER 43 and 45 ELEMENT 0.31” 30° 1.94” Cap Tube 60” E 1.81“ .253/.256” F 3.53” D C 2.17” Diameter 1.94” Top View A Dimensions – CONNECTIONS - Inches NOMINAL REFRIGERANT CAPACITY 22 410A 1-1/2 2 3 4 5 3 4 5 6 4 5 6 8 FITTING SIZE INLET OUTLET 3/8” 1/2” A C 2.51” 0.40” 7/8” E F REFRIGERANT 22 410A VCP100, ZCP180 0.50” OD x 3.00” GA 0.75” OD x 2.00” .502/.506” .627/.632” 0.78” .877/.
CATALOG 201 — Page 15 t TYPE F & EF For Refrigerants 22, 134a, 404A, 507 SAE Flare & ODF Solder Connections Sporlan Type F with SAE flare connections or Type EF with ODF solder connections are small brass bar body valves with identical internal construction and replaceable thermostatic elements. The Type F valve has a removable 100 mesh strainer as a standard feature. The Type EF has a 60 x 50 mesh insert strainer.
Page 16 — CATALOG 201 t TYPE F & EF For Refrigerants 22, 134A, 404A, 507 SAE Flare & ODF Solder Connections SAE FLARE Dimensions – ODF CONNECTIONS - Inches FITTING SIZE 1/4 SAE Elbow 3/8 SAE Elbow 3/8 SAE 1/2 SAE A 1.05 1.27 – – B – – 1.61 1.80 C 1.34 0.98 – – Bulb Sizes - Inches REFRIGERANT STANDARD CHARGES 22 134a 404 507 C 0.50 OD x 3.00 Z & ZP Series 0.50 OD x 3.00 – 0.50 OD x 3.00 1.94 1/4 SAE Inlet Strainer P/N 3008-000 3/8 SAE Inlet Strainer P/N 1538-000 3.76 2.
CATALOG 201 — Page 17 t TYPE Q & BQ For Refrigerants 22, 134a, 404A, 410A*, 507 SAE Flare & Extended ODF Solder Connections * Type Q, EQ, SQ, and BQ are not approved for R-410A applications. The Sporlan Q & BQ series are replaceable cartridge style valves designed for small refrigeration systems, such as refrigerated cases, coolers, and freezers. The externally equalized versions of these valves are ideal for air conditioning and heat pump systems.
Page 18 — CATALOG 201 t TYPE Q & BQ For Refrigerants 22, 134a, 404A, 410A*, 507 SAE Flare & Extended ODF Solder Connections * Type Q, EQ, SQ, and BQ are not approved for R-410A applications.
CATALOG 201 — Page 19 t TYPE Q & BQ For Refrigerants 22, 134a, 404A, 410A*, 507 SAE Flare & Extended ODF Solder Connections * Type Q, EQ, SQ, and BQ are not approved for R-410A applications. TYPE QE TYPE BQE QE & BQE Dimensions 1.94 1.94 CONNECTIONS - Inches A FITTING SIZE 1/4 SAE Inlet Strainer P/N 3008-000 2.43 3/8 SAE Inlet Strainer P/N 1538-000 3.93 Top View 2.02 B C 1.19 – 1.44 1.35 – 1.08 – 1.61 – – 1.
Page 20 — CATALOG 201 t TYPE G For Refrigerants 22, 134a, 404A, 507 SAE Flare Connections Sporlan Type G valve is a forged brass body, externally adjustable valve with SAE flare connections. The thermostatic element is replaceable, and the inlet connection has a removable 100 mesh strainer. This valve is designed for small refrigeration systems such as refrigerated cases, coolers and freezers.
CATALOG 201 — Page 21 t TYPE EG For Refrigerants 22, 134a, 404A, 507 ODF Solder Connections Sporlan Type EG valve is a forged brass body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable, and the inlet connection has a removable 100 mesh strainer which can be cleaned and/or replaced without removing the valve from the line. This valve is designed for small refrigeration systems such as refrigerated cases, coolers and freezers.
Page 22 — CATALOG 201 t TYPE BF For Refrigerants 22, 134a, 404A, 507 SAE Flare Connections Sporlan Type BF valve is a small brass bar body valve with SAE flare connections and balanced port construction. This valve has the same exterior dimensions as the Type F valve. The thermostatic element is replaceable, and the inlet connection has a removable 100 mesh strainer.
CATALOG 201 — Page 23 t TYPE SBF & EBF For Refrigerants 22, 134a, 404A, 507 Extended Solder Connections Sporlan Types SBF & EBF are small brass bar body valves with Extended ODF solder connections and the same balanced port construction as the Type BF valve. Both valves have replaceable thermostatic elements. The Type EBF has a 100 mesh insert strainer. The Type SBF has a 100 mesh removable strainer that can be cleaned and/ or replaced while the valve is still soldered to the system tubing.
Page 24 — CATALOG 201 t TYPE S For Refrigerants 22, 134a, 404A, 507 ODF Solder Connections Sporlan Type S valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable, and the inlet connection has a permanent 12 mesh strainer. This valve is designed for both air conditioning and refrigeration applications.
CATALOG 201 — Page 25 t TYPE EBS For Refrigerants 22, 134a, 404A, 507 Extended ODF Solder Connections Sporlan Type EBS valve is a brass bar body valve having the same physical size as the Type S valve except the Type EBS features a balanced port construction and extended ODF connections. The thermostatic element is replaceable, and the inlet connection has a permanent 12 mesh strainer. The thermostatic element is replaceable.
Page 26 — CATALOG 201 t TYPE O For Refrigerants 22, 134a, 404A, 410A, 507 ODF Solder Connections Sporlan Type O valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable, and the inlet connection has a permanent 12 mesh strainer. This valve type features a balanced port construction, and it is designed for both air conditioning and refrigeration applications. A synthetic seating surface provides tight shut-off during system off periods.
CATALOG 201 — Page 27 t TYPE O For Refrigerants 22, 134a, 404A, 410A, 507 ODF Solder Connections TYPE O with NUMBER 83 and 85 ELEMENT 2.31 1/4” ODF External Equalizer Connection 1.40 1.70 2.43 Top View C Dimensions C CONNECTIONS - Inches STRAIGHT THRU ODF SOLDER 7/8 1-1/8 1-3/8 A B C 2.09 2.21 – 2.08 2.23 2.39 0.78 0.91 0.97 4.14 Bulb Sizes - Inches A B REFRIGERANT 404A STANDARD CHARGES 22 134a 410A 507 C 0.50 OD X 3.50 – 0.50 OD X 3.50 Z & ZP Series 0.50 OD X 3.50 – 0.50 OD X 3.
Page 28 — CATALOG 201 t TYPE H and TYPE M Type H – Element Size No.
CATALOG 201 — Page 29 t TYPE V and TYPE W Type V – Element Size No. 63, Gasket Joint, Standard Tubing Length 5 Feet 22 (V) VVE-52 52 407C (N) 407A (V) 422D (V) VVE-70 70 VVE-100 100 134a (J) VJE-35 35 12 (F) 401A (X) 409A (F) VJE-45 45 VJE-55 55 404A (S) VSE-38 38 VSE-50 50 VSE-70 70 VPE-38 38 VPE-50 50 VPE-70 70 502 (R) 408A (R) 507 (P) 402A (L) INLET OUTLET SHIPPING WEIGHT - lbs.
Page 30 — CATALOG 201 t REFRIGERANT DISTRIBUTORS & AUXILIARY SIDE CONNECTORS 1126 1651 ASC Side Connection distributors for heat pump, hot gas defrost, and hot gas bypass systems. (Auxiliary Side Connectors) for hot gas defrost, hot gas bypass and reverse cycle (heat pump) systems. The Sporlan Distributor is an efficient refrigerant distributing device that assures uniform feeding of refrigerant to all passes of a multicircuited evaporator.
CATALOG 201 — Page 31 t SOLENOID VALVES 22, 134a, 401A, 402A, 404A, 407C, 502, 507 6 Proven Benefits of Sporlan Solenoid Valves n Molded coil for all sizes. n Class “F” temperature rating – Coil types MKC-1, OMKC-1, MKC-2 and OMKC-2. n Extremely rugged, simple design – few parts. A3P1 B25S2 OB10S2 E10S250 n “E” Series may be brazed without disassembly. n Tight closing through use of synthetic seating material.
Page 32 — CATALOG 201 t SOLENOID VALVES 22, 134a, 401A, 402A, 404A, 407C, 502, 507 Specifications TYPE NUMBER “E” SERIES EXTENDED CONNECTIONS “A” & “B” SERIES VALVES WITHOUT MANUAL WITH MANUAL WITHOUT MANUAL WITH MANUAL LIFT STEM LIFT STEM LIFT STEM LIFT STEM Normally Normally Normally Normally Normally Normally Closed Open Closed Closed Open Closed — — — A3P1 — — — — — A3F1 — — E3S120 — — A3S1 — — E3S130 — — A3S1 — — E5S120 — — — — — E5S130 — — — — — — — — B6P1 — MB6P1 — — — B6F1 — MB6F1 E6S130 — ME6S13
CATALOG 201 — Page 33 t SOLENOID VALVES 410A Specifications E6S130-HP R-410A valves with ODF solder connections are available from Sporlan in many different voltage and cycle ratings. Standard coils are listed in the specifications table at right. Solenoid coils are available with either an integral junction box, a 1/2” conduit boss or DIN connector. Female DIN connector assemblies are also available.
Page 34 — CATALOG 201 t BUILT-IN CHECK VALVE SERIES CE14S250 A solenoid valve with a built-in check valve is designed to replace a liquid line solenoid valve in parallel with a check valve for reverse flow. This valve may be applied in the liquid line of a supermarket case for positive shutoff during pumpdown control, while allowing full flow in the reverse direction during reverse gas defrost.
CATALOG 201 — Page 35 t BUILT-IN CHECK VALVE SERIES 22, 134a, 401A, 402A, 404A, 407C, 502, 507 SUCTION Replaceable Catch-All LIQUID Receiver DISCHARGE See-All OLDR Liquid Differential Valve Liquid Line Solenoid Valves SORIT-, CDS-, Suction Throttling Valves or Solenoid Stop Valve for Defrost TEV Evaporator Check Valve 2-Way Solenoid Defrost Valve Check Valve Evaporator Check Valve Figure 1 Distributor 3-Way 10G711B Defrost Valve Suction Header Liquid Line Solenoid Valve with Check Valve
Page 36 — CATALOG 201 t INDUSTRIAL SOLENOID VALVES FOR AIR, WATER, STEAM and LIGHT OIL W3P1 R184P1 Disc Type – Application Diaphragm Type – Application The W3P1 is the ideal size for use on air chucking devices. Generally, a very tight seat is required for this type of application. This can be achieved by using a neoprene seat in the W3P1 in place of the standard teflon. To order specify RW3P1.
CATALOG 201 — Page 37 22, 134a, 401A, 402A, 404A, 407C, 502, 507 t THREE WAY HEAT RECLAIM VALVES Sporlan Heat Reclaim Valves are tight synthetic seating three way valves designed specifically to divert hot gas from the normal to auxiliary condenser. Suction Connection “C” Type Normal (Outdoor) Condenser – De-energized – With the pilot valve de-energized, high side pressure is prevented from entering cavity above the piston-seat assembly.
Page 38 — CATALOG 201 22, 134a, 401A, 402A, 404A, 407C, 502, 507 t THREE WAY HEAT RECLAIM VALVES Capacities – Tons EVAPORATOR TEMP. °F Capacities are based on 100°F condensing temperature isentropic compression plus 50°F, evaporator temperature as shown plus 25°F superheat suction gas. EVAPORATOR TEMP. °F 40 30 20 10 0 -10 -20 -30 -40 EVAPORATOR TEMP. °F 40 30 20 10 0 -10 -20 -30 -40 40 30 20 10 0 -10 -20 -30 -40 REFRIGERANT 134a psi – PRESSURE DROP 22 2 4 B5D 8D 12D 16D B5D 8D 12D 16D 4.7 10.
CATALOG 201 — Page 39 THE PERFECT FILTER-DRIER t The universal acceptance of the Catch-All® Filter-Drier is due to its unique molded porous core, consisting of a blend of highly effective desiccants. The quality features built into it assure years of service on any refrigeration system. MOISTURE – The Catch-All Filter-Drier removes moisture from the refrigerant by adsorbing and retaining it deep within the desiccant granules.
Page 40 — CATALOG 201 22, 134a, 404A, 407C, 410A, 507 THE PERFECT FILTER-DRIER t Replaceable Core Type ODF Solder Connections The rugged construction of the Replaceable Core Catch-All has proven itself in the field for many years. The design features include: 1. The famous molded porous core for maximum contaminant removal. The core cannot swell, powder or pack – assuring ease of installation and removal. 2. The bolt and nut attachment of the end plate provides simple trouble-free installation. 3.
CATALOG 201 — Page 41 22, 134a, 404A, 407C, 410A, 507 THE PERFECT FILTER-DRIER t Liquid Line Ratings And Selection Recommendations SELECTION RECOMMENDATIONS (Tons) AIR REFRIGERATION CONDITIONING QREFRIGERANT FLOW FIELD CAPACITY R-404A COMMERCIAL & LOW REPLACEMENT R-22 R-134a R-507C R-410A Tons at 1 psi ∆P & 507 TEMPERATURE 60 PPM 50 PPM 50 PPM 50 PPM or FIELD BUILT 50 PPM EQUIPMENT UP SYSTEMS 22 & 404A 12 & 404A, 12 & 22, 407C 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 410A 134a & 507 407C 1
Page 42 — CATALOG 201 22, 134a, 404A, 407C, 410A, 507 THE PERFECT FILTER-DRIER t Liquid Line Ratings And Selection Recommendations SELECTION RECOMMENDATIONS (Tons) TYPE ESURFACE FILTERING AREA Square Inches WRATINGS AT ARI STANDARD CONDITIONS WATER CAPACITY – DROPS R-22 60 PPM C-R424-G C-R425-G C-R427-G C-485-G C-487-G C-489-G C-967-G C-969-G C-1449-G C-14411-G C-19211-G C-19213-G C-19217-G C-30013-G C-40017-G 67 902 735 64 1109 904 128 2218 1808 192 3327 2712 256 4436 3616 294 392 678
CATALOG 201 — Page 43 22, 134a, 404A, 407C, 410A, 507 THE PERFECT FILTER-DRIER t Suction Line Filter-Drier Ratings for New Systems and Clean-up after Burnout Selection Instructions Except for the values in bold (R-22/R-407C/R-410A at 40°F; 8 psi pressure drop), the flow capacities are rated at the maximum recommended pressure drop for permanent installation.
Page 44 — CATALOG 201 t THE PERFECT FILTER-DRIER Significance of the Type Number The letters and numerals in the Catch-All® type number each have a significance. The “C” indicates Catch-All. The FIRST TWO OR THREE DIGITS indicate cubic inches of desiccant. The LAST ONE OR TWO DIGITS indicate fitting size in eighths of an inch. For sealed models, a “-S” following the last digit indicates solder fittings, and NO LETTER indicates a flare fitting.
CATALOG 201 — Page 45 REVERSIBLE HEAT PUMP FILTER-DRIERS t Design Features n New product line-up with enhanced flow capacities deliver system protection solutions for today’s system sizes. n Filter-drier operates in either flow direction with low pressure drop. n Rugged metal check valve designed for maximum flow capacity. n Sporlan dependable molded core used for maximum filtration ability. When flow reverses, dirt already collected remains in the filter-drier.
Page 46 — CATALOG 201 t STEEL SUCTION LINE ACCUMULATORS U-Tube Style Accumulators The U-tube accumulator design is a result of extensive laboratory testing plus detailed investigation of the various accumulators currently available. It takes into account essential requirements such as safe holding volume (relative to the system’s total charge), protected flow control for positive refrigerant and oil return, and minimum pressure drop across the accumulator.
CATALOG 201 — Page 47 tSTEEL STEEL SUCTION LINE ACCUMULATORS SUCTION LINE ACCUMULATORS MODEL NUMBER DIMENSIONS CONN. Inches Inches (ODF) LENGTH O.D. CAPACITY Ounces* (wt.) Dimensions and Flow Data VA314S VA315S 1/2 5/8 10.35 10.35 3 3 35 35 VA355S 5/8 15.05 3 55 VA356S 3/4 15.05 3 54 PA4065-9-5C 5/8 9.62 4 60 PA4065-9-6C 3/4 9.62 4 58 VPA589-6SRD 3/4 9.62 5 89 VPA589-7SRD 7/8 9.63 5 86 VPA5812-7SRD 7/8 12.88 5 125 VPA5811-7SRD 7/8 11.
Page 48 — CATALOG 201 t STEEL RECEIVERS Features and Benefits n Integral 430°F (221°C) fuse plug n PTFE gasket seal for valve n UL file number SA7946 and CSA file number LR41494 with 3” to 5” models at 500 psi M.R.P. and 6” models at 450 psi M.R. P. n Powder coating surpasses 500 hour ASTM salt spray n Manufactured in ISO 9001/ISO 14001 registered facility LISTED Configuration Options n 3” through 6” diameters with maximum length of 36” providing up to 40 lbs.
CATALOG 201 — Page 49 BALL VALVE SERIES t EBV Series (Welded) EBVT Series (Welded with Access Fitting) n Robotically welded body joint. 100% factory tested to ensure positive, leak-free performance. Forged brass body construction with extended copper fittings and optional access fittings. n Full size ports for unrestricted flow on most sizes (3/8” through 3-1/8”) n Dual Teflon seals surround the polished, brass ball with a secondary seal to prevent leakage due to foreign material.
Page 50 — CATALOG 201 MOISTURE and LIQUID INDICATOR t 8 Outstanding Benefits 1. One Indicator for Refrigerants 12, 134a, 22, 404A, 407C, 410A, 502 and 507. The See•All Moisture and Liquid Indicator provides a true moisture indication for Refrigerants 12, 134a, 22, 404A, 407C, 410A, 502 and 507. The See•All® is also suitable for Refrigerants 401A & B, 402 A & B, 408A and 409A. The dark green indicates dry and a bright yellow indicates wet.
CATALOG 201 — Page 51 t SUCTION FILTERS WITH THE OPTIONAL RELIEF FEATURE Design Benefits Sporlan offers an exclusive concept in Suction Filter design – a filter with an optional relief feature. When flow is in one direction, the bypass relief feature is active. If the pressure drop across the element becomes excessive the bypass relief will open slightly to maintain sufficient gas flow and assure proper cooling of the hermetic motor.
Page 52 — CATALOG 201 t REPLACEABLE SUCTION FILTERS The Replaceable Suction Filter shell, used with RPE-48-BD pleated filter element, is designed to be installed in the suction line of new systems to remove circulating contaminants.
CATALOG 201 — Page 53 tCRANKCASE DISCHARGEPRESSURE BYPASS VALVES REGULATING VALVES SHGB-15 ADRI ADRHE-6 DRHE-6 HGBE-5 SHGB-8 and The Sporlan line of discharge bypass valves are designed to provide an economical method of compressor capacity control in place of cylinder unloaders or to handle unloading requirements below the last step of cylinder unloading.
Page 54 — CATALOG 201 t DISCHARGE BYPASS VALVES Capacities – Tons DISCHARGE BYPASS VALVES Capacities based on 6°F evaporator temperature change from closed to rated opening (does not apply to pilot operated models), discharge temperature 30°F above isentropic compression, 100°F condensing temperature, 0°F subcooling, 25°F superheat at the compressor and includes both the hot gas bypassed and liquid refrigerant for desuperheating, regardless of whether the liquid is fed through the system thermostatic exp
CATALOG 201 — Page 55 t CRANKCASE PRESSURE REGULATING VALVES Crankcase Pressure Regulating Valves are designed to prevent overloading of the compressor motor by limiting the crankcase pressure to a predetermined maximum value during and after a defrost cycle or a normal shutdown period. These valves automatically throttle the vapor flow from the evaporator until the compressor can handle the load. Sporlan manufactures five adjustable direct acting models...CRO-4, CRO-6, CROT-6, CRO-10 and CROT-10...
Page 56 — CATALOG 201 t CRANKCASE PRESSURE REGULATING VALVES Capacities – Tons Capacities based on 100°F condensing temperature, 10°F superheat, 0°F subcooling, and 2 psi pressure drop across valve.
CATALOG 201 — Page 57 t HEAD PRESSURE CONTROL VALVES Listed by Underwriters’ Laboratories, Inc. Guide SFJQ2 File No. SA5460 ORI-6 OROA-5 ORD-4 Sporlan Head Pressure Control for systems with air cooled condensers can be accomplished with several valve types or the ORI/ORD combination. The valve types are: LAC-4, OROA-5, LAC-5 and the LAC-10. Please refer to Bulletin 90-30 or Catalog 410A for a complete explanation of operation and application.
Page 58 — CATALOG 201 t HEAD PRESSURE CONTROL VALVES Low Ambient (Winter) Capacities – Tons Of Refrigeration 0 20 -20 410A (295) 0 20 — — — — — — 18.3 25.8 — — — — — — 21.0 29.6 — — — — — — 25.2 35.5 — — — — — — 13.0 18.4 — — — — — — 15.0 21.2 — — — — — — 18.1 25.5 — — — — — — — — — — — — -20 404A (210) 0 20 -20 507 (210) 0 20 1 2 5 10 15 20 25 30 1 2 5 10 15 20 25 30 1 2 5 10 15 20 25 30 1 2 5 10 15 20 25 30 1 2 5 10 15 20 25 30 1 2 5 10 15 20 25 30 1.19 1.67 2.62 3.67 4.45 5.09 5.64 6.
CATALOG 201 — Page 59 t HEAD PRESSURE CONTROL VALVES High Ambient (Summer) Capacities – Tons Of Refrigeration — — — — — — — — — — — — — — — — — — — — — 404A 507 1 2 3 4 5 6 8 10 1 2 3 4 5 6 8 10 ORD-4 19.7 27.2 32.8 37.5 41.6 45.3 51.8 57.5 12.2 16.8 20.3 23.2 25.8 28.0 32.1 35.6 — — — — — ORI-10 7.35 10.7 13.3 15.5 17.5 19.4 22.6 25.5 4.90 7.13 8.88 10.4 11.7 12.9 15.1 17.0 — — — — — 1.61 2.25 2.73 3.14 3.50 3.82 4.39 4.89 1.57 2.20 2.67 3.07 3.42 3.74 4.30 4.79 3.43 7.33 6.49 5.01 13.9 4.85 10.
Page 60 — CATALOG 201 t DEFROST DIFFERENTIAL PRESSURE REGULATING VALVES DDR-20 OLDR-16 In many supermarket applications refrigerant gas from the discharge line or from the top of the receiver is used for defrost. This method of defrost diverts a portion of the hot gas or cool gas (from the top of the receiver) to the suction line and back through the evaporator being defrosted. The gas condenses in the evaporator and flows in reverse, through check valves, around the TEV and liquid line solenoid valve.
CATALOG 201 — Page 61 tTHERMOSTATIC DEFROST DIFFERENTIAL REGULATING VALVES EXPANSION PRESSURE VALVES Figure 5 DDR-20 Discharge Differential Regulator Typical Piping Diagram ORI Head Pressure Control Valve Normal Condenser 8D-, 12D-, 16DHeat Reclaim Valve Reclaim Condenser Check Valve OCVOil Check Valve Type ORD-4 Discharge Bypass Receiver Pressurization Valve NOTE: Discharge Differential Pressure Regulating Valve (DDR-20) and Liquid Differential Pressure Regulating Valve [(O)LDR, AND XTO] are not t
Page 62 — CATALOG 201 t EVAPORATOR PRESSURE REGULATING VALVES The Sporlan line of evaporator pressure regulating (EPR) valves are designed to provide an accurate and economical means of balancing system capacity and load requirements during “low” loads and/or while maintaining different evaporator conditions on multi-temperature evaporator systems. These valves control evaporator temperature by maintaining evaporator pressure.
CATALOG 201 — Page 63 t EVAPORATOR PRESSURE REGULATING VALVES (S)ORIT-12, -15 and -20 Features n High side pilot for improved temperature control and low ∆P operation n Adjustable n Optional solenoid “stop” feature to close valve during defrost n Normally open design allows system evacuation without manual operator These EPRs are pilot operated using “high side” pressure and require a pilot supply connection from the compressor discharge to operate.
Page 64 — CATALOG 201 t EVAPORATOR PRESSURE REGULATING VALVES (S)ORIT-PI-2, -3, -4 and -5 Features n Piloted internally (No high side connection required) n Superior corrosion resistance n Optional solenoid “stop” feature to close valve during defrost and n Optional electric open feature for Certified “two temperature operation” n Manual lift stem (standard) to allow system evacuation These EPRs are Piloted Internally using the natural pressure drop across the valve to operate and do not require a “high si
CATALOG 201 — Page 65 t ELECTRONIC TEMPERATURE CONTROL SYSTEMS SER, SERI, SEHI Sporlan Electric Expansion Valves (EEVs) are currently available in nominal R-407C capacities from 2 to 400 tons (7 to 1400 kW). Therefore, they are applicable on all the same types of systems found in the air conditioning and refrigeration industry as thermostatic expansion valves. Sporlan electric valves are designed for compatibility with all current halocarbon refrigerants, including CFCs, HCFCs, HFCs, R-410A and R-744.
Page 66 — CATALOG 201 t ELECTRONIC TEMPERATURE CONTROL SYSTEMS CDS-4, -7, -9 and -17 CDS valves are designed for precise and energy efficient refrigerant flow control in a variety of applications, while contributing little to no additional pressure drop to the system. Built around balanced ports, CDS valves require less than 4 watts of input power to move (and no power to hold position).
CATALOG 201 — Page 67 Nomenclature/Ordering Instructions CDS Valve Family – T – 17 Optional Inlet Pressure Tap – 1-3/8 ODF Valve Model 20 – Fitting Size – S S = Stripped and tinned cable ends. Custom Connectors available Cable Length For complete information see your Sporlan Wholesaler, our website at www.sporlan.com, or write Sporlan and request Bulletin 100-60.
Page 68 — CATALOG 201 t ELECTRONIC TEMPERATURE CONTROL SYSTEMS Sporlan offers a variety of controllers for use in refrigeration and air conditioning systems. Applications include self-contained food service equipment, cold rooms and chillers. With over 80 different models, Sporlan can satisfy almost any customer requirement. Small, standalone controllers include the compact Kelvin and larger Superheat and Refrigeration controllers.
CATALOG 201 — Page 69 t ELECTRONIC TEMPERATURE CONTROL SYSTEMS CONTROLLER PACKAGES TCB Temperature Control Board/IB Interface Board The TCB interface/controller was designed to allow all Sporlan step motors to be modulated in response to an externally generated signal. The IB and TCB will accept a 4-20 milliamp, or 0-10 volt DC inputs and will stroke the valve in proportion to that signal.
Page 70 — CATALOG 201 t OIL LEVEL CONTROL SYSTEM Sporlan’s Oil Level Control System Components were developed to offer the refrigeration industry an oil level control system of the highest quality. The heart of the system is the Oil Level Control which when matched with the Oil Reservoir and Oil Differential Check Valve maintains a minimum oil level in the compressor crankcase during all phases of system operation.
CATALOG 201 — Page 71 t OIL LEVEL CONTROL SYSTEM Compressor Adaptor Requirements COMPRESSOR MANUFACTURER Bitzer Bock COMPRESSOR MODEL NUMBER COMPRESSOR ATTACHMENT PATTERN SPORLAN ADAPTOR KIT NUMBER SEALING METHOD SIGHTGLASS 2 KC, 2JC, 2HC, 2GC, 2 FC, 2EC, 2DC, 2CC, 4FC, 4EC, 4DC, 4CC 1-1/8” Thread 4VC, 4TC, 4PC, 4NC 3 Bolt, 1-7/8” B.C. (47.6 mm B.C.) None 4J, 4H, 4G, 6J, 6H, 6G, 6F 4 Bolt, 50 mm B.C. 8GC, 8FC 3 Bolt, 1-7/8” B.C. (47.6 mm B.C.
Page 72 — CATALOG 201 SERIES OIL FILTER t Design Benefits The Sporlan Catch-All or SF-283-F Suction Filter has been used for many years as an oil filter in refrigeration rack systems with mineral or alkylbenzene oil. n Virtually eliminates the need for oil changes due to suspended particulate in circulation With the use of the new polyolester (POE) oils, system chemistry changed. Unlike mineral and alkylbenzene oils, POE oil has solventlike tendencies.
OFFER OF SALE The items described in this document and other documents and descriptions provided by Parker Hannifin Corporation, its subsidiaries and its authorized distributors (“Seller”) are hereby offered for sale at prices to be established by Seller. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and Conditions.
© 2011 Parker Hannifin Corporation 72011 / Catalog 201 Parker Hannifin Corporation Sporlan Division 206 Lange Drive • Washington, MO 63090 USA phone 636 239 1111 • fax 636 239 9130 www.sporlan.