May 2012 / BULLETIN 100-40 Electric Pressure Regulating Valves CDS Series
Page 2 — BULLETIN 100-40 Sporlan CDS valves are available in two styles - the CDS-2, CDS-4 and CDS-7 provide 2500 steps of resolution, while the larger CDS-9, CDS-16 and CDS-17 provide 6386 steps of resolution. 12 VDC step motors coupled to an integral gear reduction system give the valves unparalleled accuracy and repeatability over the entire operating range.
BULLETIN 100-40 — Page 3 The CDS-9, -16 and -17 are supplied with a hermetic cable connection. CAUTION: No attempt should be made to remove the hermetic cable. The CDS-2, -4 and -7 are supplied with a removable cable. All external parts of the valve are brass, copper or stainless steel, and meet or exceed ASTM standard B-117 for corrosion resistance.
Page 4 — BULLETIN 100-40 SPECIFICATIONS Valves CDS -2, -4, -7 Valves CDS -9, -16, -17 Motor Type 2 phase, bipolar wet motor Compatible Refrigerant All common HCFC and HFC refrigerants including R-410A and subcritical R-744 Compatible Oils All common Mineral, Polyolester and Alkybenzene oils 12 VDC-5% +10% (measured at the valve leads) Supply Voltage* Cable Type IP66 Removable Hermetic 75 ohms ± 10% Phase Resistance 100 ohms ± 10% Phase Inductance 43 MHz ± 20% 62 MHz ± 20% Nominal Current*
BULLETIN 100-40 — Page 5 REFERENCE DIMENSIONS – Inches (mm) CDS-9 CDS-16 Available Fittings Available Fittings 5/8” ODF 1-3/8” ODF 7/8” ODF 1-1/8” ODF 1-3/8” ODF 5.27" (134) 1/4" SAE (Optional) 1.60" (41) 2.125" (54) HEX 1.375" (35) HEX SPORLAN 0.69" (18) FLOW 7.25" (184) 1/4" SAE 4.10" (Optional) (104) 2.10" (53) FLOW 2.18" (55) 1.50" (38) CDS-17 Available Fittings 1-3/8” ODF 9.88” (251) 1-5/8” ODF 9.88” (251) 2-1/8” ODF 10.62” (270) 5.61" (143) 1/4" SAE (Optional) 0.91" (23) 1.
Page 6 — BULLETIN 100-40 Evaporator Temp. (°F) Valve Model FLOW CAPACITY - SUCTION (TONS) CDS-17 CDS-16 CDS-9 CDS-7 CDS-4 CDS-2 40 REFRIGERANT R-22 R-134a R-404A R-407A Pressure Drop Across Valve (psid) 0.5 1 3 5 10 0.5 1 3 5 10 0.5 1 3 5 10 0.5 1 3 5 10 0.53 0.73 1.25 1.59 2.28 0.42 0.59 1.00 1.29 1.76 0.48 0.67 1.14 1.46 2.12 0.51 0.71 1.20 1.53 2.19 20 0.43 0.61 1.03 1.32 1.84 0.34 0.47 0.79 1.01 1.35 0.39 0.55 0.93 1.19 1.68 0.41 0.57 0.97 1.26 1.73 0 0.35 0.49 0.
BULLETIN 100-40 — Page 7 Evaporator Temp. (°F) Valve Model FLOW CAPACITY - SUCTION (TONS) continued CDS-2 CDS-4 CDS-7 CDS-9 CDS-16 R-407C R-410A R-422D R-507A R-744* Pressure Drop Across Valve (psid) 1 3 5 10 0.51 0.71 1.21 1.55 2.21 0.65 0.91 1.55 1.98 2.77 0.43 0.60 1.02 1.31 1.87 0.48 0.67 1.14 1.46 2.12 – – – – – 20 0.41 0.58 0.98 1.27 1.74 0.54 0.76 1.29 1.64 2.36 0.35 0.48 0.82 1.07 1.46 0.39 0.55 0.93 1.19 1.69 – – – – – 0 0.33 0.46 0.77 0.98 1.32 0.44 0.62 1.05 1.34 1.88 0.
Page 8 — BULLETIN 100-40 Evaporator Temp. (°C) Valve Model FLOW CAPACITY - SUCTION (kW) CDS-7 CDS-4 CDS-2 5 CDS-9 R-134a R-404A R-407A Pressure Drop Across Valve (bar) 0.03 0.06 0.2 0.4 0.7 0.03 0.06 0.2 0.4 0.7 0.03 0.06 0.2 0.4 0.7 0.03 0.06 0.2 0.4 0.7 1.75 2.44 4.36 6.09 8.18 1.40 1.96 3.50 4.92 6.32 1.61 2.24 4.01 5.60 7.60 1.68 2.35 4.20 5.86 7.87 -5 1.47 2.06 3.68 5.22 6.76 1.15 1.60 2.86 3.94 4.99 1.33 1.86 3.33 4.65 6.20 1.39 1.94 3.47 4.93 6.37 1.23 1.71 3.06 4.26 5.
BULLETIN 100-40 — Page 9 Evaporator Temp. (°C) Valve Model FLOW CAPACITY - SUCTION (kW) continued CDS-2 CDS-4 CDS-7 R-422D R-507A R-744* Pressure Drop Across Valve (bar) 0.03 0.06 0.2 0.4 0.7 0.03 0.06 0.2 0.4 0.7 0.03 0.06 0.2 0.4 0.7 0.03 0.06 0.2 0.4 0.7 0.03 0.06 0.2 0.4 0.7 – – – -5 1.41 1.96 3.51 4.96 6.39 1.84 2.57 4.59 6.41 8.66 1.18 1.65 2.95 4.18 5.39 1.34 1.87 3.33 4.66 6.23 – – – – – -15 1.15 1.60 2.86 3.95 5.03 1.53 2.14 3.83 5.35 7.09 0.95 1.33 2.38 3.30 4.20 1.10 1.53 2.
Page 10 — BULLETIN 100-40 CDS-17 CDS-16 CDS-9 CDS-7 CDS-4 CDS-2 Evaporator Temp. (°F) Valve Model FLOW CAPACITY - LIQUID (TONS) 40 0 -40 40 0 -40 40 0 -40 40 0 -40 40 0 -40 40 0 -40 REFRIGERANT R-22 R-134a R-404A R-407A Pressure Drop Across Valve (psid) 0.5 1 3 5 10 0.5 1 3 5 10 0.5 1 3 5 10 0.5 1 3 5 10 3.37 3.21 3.04 7.24 6.91 6.53 19.0 18.1 17.1 28.9 27.6 26.1 50.7 48.4 45.7 52.2 49.8 47.1 4.71 4.49 4.24 10.2 9.70 9.17 26.2 25.0 23.6 40.2 38.3 36.2 70.8 67.5 63.8 72.
BULLETIN 100-40 — Page 11 CDS-17 CDS-16 CDS-9 CDS-7 CDS-4 CDS-2 Evaporator Temp. (°F) Valve Model FLOW CAPACITY - LIQUID (TONS) continued 40 0 -40 40 0 -40 40 0 -40 40 0 -40 40 0 -40 40 0 -40 REFRIGERANT R-407C R-410A R-422D R-507A R-744* Pressure Drop Across Valve (psid) 0.5 1 3 5 10 0.5 1 3 5 10 0.5 1 3 5 10 0.5 1 3 5 10 0.5 1 3 5 10 3.31 3.11 2.89 7.12 6.70 6.22 18.7 17.5 16.3 28.5 26.8 24.9 49.9 46.9 43.6 51.4 48.3 44.9 4.63 4.35 4.04 10.0 9.40 8.73 25.8 24.
Page 12 — BULLETIN 100-40 CDS-17 CDS-16 CDS-9 CDS-7 CDS-4 CDS-2 Evaporator Temp. (°F) Valve Model FLOW CAPACITY - DISCHARGE (TONS) 40 0 -40 40 0 -40 40 0 -40 40 0 -40 40 0 -40 40 0 -40 REFRIGERANT R-22 R-134a R-404A R-407A Pressure Drop Across Valve (psid) 0.5 1 3 5 10 0.5 1 3 5 10 0.5 1 3 5 10 0.5 1 3 5 10 0.74 0.69 0.63 1.56 1.45 1.32 4.36 4.05 3.71 6.52 6.07 5.55 11.2 10.4 9.53 11.7 10.9 9.94 1.04 0.96 0.88 2.19 2.04 1.86 6.03 5.61 5.14 9.07 8.44 7.72 15.7 14.6 13.
BULLETIN 100-40 — Page 13 CDS-17 CDS-16 CDS-9 CDS-7 CDS-4 CDS-2 Evaporator Temp. (°F) Valve Model FLOW CAPACITY - DISCHARGE (TONS) continued 40 0 -40 40 0 -40 40 0 -40 40 0 -40 40 0 -40 40 0 -40 REFRIGERANT R-407C R-410A R-422D R-507A Pressure Drop Across Valve (psid) 0.5 1 3 5 10 0.5 1 3 5 10 0.5 1 3 5 10 0.5 1 3 5 10 0.75 0.70 0.63 1.58 1.46 1.32 4.43 4.09 3.71 6.63 6.12 5.55 11.4 10.5 9.53 11.9 11.0 9.94 1.05 0.97 0.88 2.23 2.05 1.86 6.13 5.66 5.14 9.21 8.51 7.72 15.
Page 14 — BULLETIN 100-40 CORRECTION FACTORS - SUCTION & DISCHARGE REFRIGERANT 0° 10° 20° Liquid Temperature Entering Expansion Valve °F 30° 40° 50° 60° 70° 80° 90° 100° R-22 R-134a R-404A R-407A R-407C R-410A R-422D R-507A R-744 1.22 1.27 1.34 1.28 1.26 1.26 1.34 1.35 1.09 1.18 1.22 1.29 1.23 1.22 1.22 1.29 1.29 1.05 1.15 1.18 1.23 1.19 1.18 1.18 1.23 1.24 1.0 Correction Factor, CF Liquid Temperature 1.11 1.07 1.04 1.0 0.96 1.14 1.09 1.05 1.0 0.95 1.17 1.12 1.06 1.0 0.94 1.14 1.10 1.05 1.0 0.
BULLETIN 100-40 — Page 15 OFFER OF SALE The items described in this document and other documents and descriptions provided by Parker Hannifin Corporation, its subsidiaries and its authorized distributors (“Seller”) are hereby offered for sale at prices to be established by Seller. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and Conditions.
© 2012 Parker Hannifin Corporation 052012 / Bulletin 100-40 Parker Hannifin Corporation Sporlan Division 206 Lange Drive • Washington, MO 63090 USA phone 636 239 1111 • fax 636 239 9130 www.sporlan.