user manual

6300/6310 Treadmill Electronics Repair Manual – Incline
6300/6310 Voltage to Incline Test Procedure
1. Put multimeter to the DC Voltage setting. Insert the red probe into the CON3 white wire connector.
Insert the black probe into the CON3 green wire connector. Turn on unit power.
2. Press INCL<> key. K4 relay clicks; LED4 lights. Normal reading: +35 VDC. Incline operates up.
3. Press INCL<> key. K2 relay clicks; LED3 lights. Normal reading: -35 VDC. Incline operates down.
6300/6310 Voltage to Incline Test Results
If not as above, inspect the following:
1. In manual mode, press an incline up or down key. The display should beep once. If not, inspect the
display.
2. Test the transformer voltage (see TESTING - TRANSFORMER.1 in Motor System Operation); Check
for 35 VDC across the orange wires.
3. If LED 5 on the drive board lights or ERR7 appears, recalibrate the incline set and test incline operation
again.
4. If the display beeps when incline keys are pressed, but the drive board incline up and down LEDs don’t
light, inspect the ribbon cable (check continuity). If the ribbon cable is good and the transformer is good,
replace the drive board.
INCLINE.03