Use and Care Manual

Follow This Step-By-Step
Guide To Using Your Generator
GEN4000TRI
WARNING
Always follow Warning labels placed on the
generator, and read and follow all Warning
labels included inside the Product Manual.
WARNING: NEVER use a generator inside
a home or a garage, EVEN IF the doors
and windows are open.
ONLY USE OUTSIDE and far way from
windows, doors and vents leading into an
enclosed area.
Using a generator indoors can kill you in
minutes. The generator produces an
exhaust that contains carbon monoxide.
This is a poison you cannot see or smell.
Do not attach a chain or rope to secure the
generator to a post as this can be difficult to
remove in the event of an emergency.
4,000 Surge / 3,500 Running Watts
www.sportsmanseriesbrand.com/generators
IF THERE IS ANY QUESTION ABOUT A
CONDITION BEING SAFE OR UNSAFE,
DO NOT OPERATE THIS PRODUCT!
Visit our website for Troubleshooting & Frequently Asked Questions
Need Help? Call Us First!
Monday-Friday 8:00-4:00 Central Time
TOLL-FREE NATIONWIDE HELP LINE! 866-460-9436
OIL IS NOT INCLUDED WITH THIS
GENERATOR. IT IS SOLD SEPARATELY.
Read and understand instruction manual
before using generator.
GENERATOR SPECIFICATIONS:
• 4 - 120V A/C Outlets
• 1 - 120V RV Outlet
• 1 - 12V D/C Outlet
• Recoil Start
• 7 HP OHV Engine
• Displacement: 212cc
• Phase: Single
AC Voltage: 120V @ 60Hz
• Decibel Rating <68 db @ 24 Feet
• Complies with EPA emissions
Engine Run Time: 10 Hours @ 50% Load (Gas)
Engine Run Time: 12 Hours @ 50% Load (LP)
• Fuel Tank Capacity: 3.6 Gallon
High Altitude Use: This generator is not
recommended for high altitude use above 3,000 feet.
• If you are using a generator above sea level,
the generator may not function properly because
of air flow getting through the mixer.
• Warranty: 2 YEAR Limited Emissions
• Warranty: 1 YEAR Limited
GEN4000TRI
WARNING
Always follow Warning labels placed on the
generator, and read and follow all Warning
labels included inside the Product Manual.
WARNING: NEVER use a generator inside
a home or a garage, EVEN IF the doors
and windows are open.
ONLY USE OUTSIDE and far away from
windows, doors and vents leading into an
enclosed area.
Using a generator indoors can kill you in
minutes. The generator produces an
exhaust that contains carbon monoxide.
This is a poison you cannot see or smell.
Do not attach a chain or rope to secure the
generator to a post as this can be difficult to
remove in the event of an emergency.
4,000 Surge / 3,500 Running Watts
IF THERE IS ANY QUESTION ABOUT A
CONDITION BEING SAFE OR UNSAFE,
DO NOT OPERATE THIS PRODUCT!
DO NOT CONNECT electrical devices until AFTER the generator is started.
Outlets available on this
generator, from left to right:
• 4 x 120 Volt A/C Outlets
• 1 x 120 Volt RV Outlet
• 1 x 12 Volt D/C Outlet
NOTES
TRI FUEL : GAS/ LP / NG GENERATOR
CONTROL PANEL FEATURES
TRI FUEL : GAS/ LP / NG GENERATOR
Power
Switch
SPORTSMANSPORTSMANSPORTSMANSPORTSMANSPORTSMANSPORTSMAN
www.sportsmanseriesbrand.com/generators
Visit our website for Troubleshooting & Frequently Asked Questions
Need Help? Call Us First!
Monday-Friday 8:00-4:00 Central Time
TOLL-FREE NATIONWIDE HELP LINE! 866-460-9436
SPORTSMANSPORTSMANSPORTSMANSPORTSMANSPORTSMANSPORTSMAN
Ground
120V AC
120V RV
AC Reset
12V DC VoltmeterDC Reset
1
2
3
Remove generator from package
Add Oil
Connect
Fuel
Oil Type: SAE10W-30 Oil (Must add BEFORE first use)
Oil Capacity: 18.5 fluid oz
Because this generator includes Low Oil Shut Off, the generator
will not start with low oil)
If using Gasoline, add fuel to tank and turn Gasoline Fuel Petcock
to On (Fig C).
If using LP, connect regulator hose (Fig A) to Propane Fuel Tank
and to the Gas Inlet (Fig B). Make sure the LPG adapter (Fig E) is
connected (Fig E).
If using NG, replace the LPG adapter with the NG adapter (Fig E).
(NOTE: Adapters are labeled with LPG and NG. (Fig F))
Directly connect to the NG system with a gas hose no less than
3/8" (inside diameter), no longer than 10 ft (3m), and to the gas
inlet (Fig B). DO NOT use the LP regulator hose (Fig A) for NG.
Refer to the manual for detailed information.
Add Fuel
Power
Switch
Recoil
Start
Add Oil
(Figure F)
Fuel Petcock (Figure C)
Fuel Off
Fuel On
Choke (Figure D)
Regulator Hose (Figure A)
Gas Inlet (Figure B)
Propane / NG
Adapter (Figure E)
Use the generator OUTDOORS in a WELL VENTILATED AREA.
DO NOT CONNECT electrical devices until AFTER the generator
is started.
Turn Power Switch to ON
Adjust the CHOKE to CLOSED position (Figure D)
To start the generator manually, use the Recoil (Pull) Start.
Once the engine has started, wait an addtional 2 minutes to allow
the engine to warm up. Then turn the CHOKE LEVER to OPEN
position. You can now connect electrical devices.
4
Start The Generator

Summary of content (1 pages)