Full Product Manual

Item # GEN3500DFI Portable Dual Fuel Invertor Generator
15
STARTING THE GENERATOR
STOP!
Before starting this generator, confirm that all the steps in the section titled, “Preparing the Generator for Use,” of this manual have been
correctly completed. If unsure about how to perform any of these steps, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for
customer service.
Disconnect all electrical loads from this generator before attempting to start.
To start this generator:
1. Confirm that there are no electrical devices connected to this generator. Connected devices may increase the difficulty in starting the engine.
2. Confirm that this generator is properly grounded. (See “Ground the Generator” section of this manual.)
3A. If using gasoline, turn the fuel switch to the “on” position.
3B. If using propane, turn the fuel switch to the “off” position.
4. Pull the choke lever towards you.
5. Set the engine switch to the “on” position.
6. Slowly pull on the recoil starter handle, shown in Figure 4, until a slight resistance is felt. Then pull briskly to start the engine. Gently return the
cord into the generator to avoid damage to the starter or housing. Never allow the cord to snap back.
7. If the engine fails to start, repeat step 6.
NOTE: After repeated attempts to start the engine, consult the troubleshooting guide before attempting again. If problems persist,
call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time.
8. Once the engine has started, GRADUALLY push the choke lever until the engine levels off. Then let the engine run
approximately 5 minutes BEFORE adding appliances or tools.
Choke Rod
The choke is used to provide an enriched fuel mixture when starting a cold engine.
It can be opened and closed by operating the choke rod manually.
Figure 4
The Recoil Start is located on the left
side of the generator.
Choke OUT/OFF
To Start
Choke IN/ON
To Run