Full Product Manual

Item # GEN3500DFI Portable Dual Fuel Invertor Generator
19
SOME NOTES ABOUT POWER CORDS
Long or thin cords can require more wattage from a generator to power an electrical device. Figure 6 shows the recommended cords according to
the power requirement of the electrical device. When using cords that exceed these specifications, allow for the electrical device to have a slightly
higher rated wattage requirement.
Device Requirements
Max. Cord Length (ft) by Wire Gauge
Amps
Watts (120V)
Watts (240V)
#8 wire
#10 wire
#12 wire
#14 wire
#16 wire
2.5
300
600
NR
1000
600
375
250
5
600
1200
NR
500
300
200
125
7.5
900
1800
NR
350
200
125
100
10
1200
2400
NR
250
150
100
50
15
1800
3600
NR
150
100
65
NR
20
2400
4800
175
125
75
50
NR
25
3000
6000
150
100
60
NR
NR
30
3600
7200
125
65
NR
NR
NR
40
4800
9600
90
NR
NR
NR
NR
Figure 6 - Maximum Extension Cord Lengths by Power Requirement
SWITCHING BETWEEN GASOLINE & PROPANE FUEL
In order to switch between gasoline and propane fuel, you must turn off the current fuel. For example, if using gasoline and you want to switch to
propane, turn the gasoline Fuel Switch to OFF position and let the engine continue to run until it burns off all remaining gasoline fuel in carburetor.
Then turn the propane tank ON. If using propane and you want to switch to gasoline, turn the propane tank OFF and turn the gas Fuel Switch ON.