Byte
Bits
Parameter
Description
0
0 7
Leader
Always a value of 0xAA.
1
0 7
Length
0x0A (10 decimal)
2
0 7
Command Code.
0x35 = Initiate proprietary dock mode track.
3 -4
0 - 15
Interval
Interval in minutes between the track points. 2 to
65535 minutes. (A setting of 2 actually results in a 2.5
minute interval, any other value results in an interval
of that many minutes).
5
0 - 7
Byte 0 value
The value to transmit as byte 0
6
0 - 7
Byte 7 value
The value to transmit as byte 7.
7
0 - 7
Byte 8 value
The value to transmit as byte 8.
8-9
0 - 15
CRC
4.2.2.16 “Update Proprietary Track Data” command
This command is used to change the user programmable data in a proprietary track message. If a proprietary track
session is not in progress, it is ACK’d but will do nothing.
Update proprietary track data command format
Byte
Bits
Parameter
Description
0
0 7
Leader
Always a value of 0xAA.
1
0 7
Length
0x08
2
0 7
Command Code.
0x31 = Update proprietary track.
3
0 7
Byte 0 value
The value to transmit as byte 0
4
0 7
Byte 7 value
The value to transmit as byte 7.
5
0 7
Byte 8 value
The value to transmit as byte 8.
6-7
0 15
CRC