5.2.2 Step 2: Set the channel that you wish to perform the test on.
Use the “setup” command for this. Using the configuration application in “advanced” mode:
Tap the “auth” button.
Send the command: “setup <ch> 3 60 120”
Where “<ch> =
o 0 = Channel A
o 1 = Channel B
o 2 = Channel C
o 3 = Channel D
5.2.3 Step 3: Start the desired mode.
Using the configuration application in “advanced” mode:
Tap the “auth” button.
For CW Mode, send the command: “raw aa06fc01”
For Mod Mode, send the command: “raw aa06fc03”
To send a single test packet, send the command: “raw aa06fc02”
When entering each of the commands above, you should see an ACK: “aa05fc” and 2 bytes of CRC
Repeat steps 2 and 3 for the tests you want to perform on each channel.
5.2.4 Step 4: Disable the test commands.
After turning the power off following the last test, use the configuration application in “advanced” mode to do the
following:
Tap the “auth” button
Send the command: “raw aa067600”
Watch for the ACK, which should be “aa0576” and 2 bytes of CRC
5.2.5 Step 5: Restore the desired setup.
Tap the “auth” button.
Send the command: “setup <ch> <transmit attempts> <min time between attempts> <max time between
attempts>”
Note: Factory default settings are: “setup 0 3 60 120”