User's Manual

30 SpotCell 100
1.3 Architecture
1.3.1 Physical
Frequency Bands Uplink: 824-849 MHz
Downlink: 869-894 MHz
Sub-Bands Complete A or B sub-bands
Formats Supported AMPS, CDMA/1xRTT, TDMA/GSM/GPRS/EDGE
Coverage Area Fully adaptive, supports multiple simultaneous users
Up to 25,000 ft
2
(2350 m
2
)
System Gain Automatic, fully adaptive,
Maximum 93 dB downlink, 86 dB uplink
Downlink Operating Range -106 to -44 dBm (receive isotropic power); coverage reduced
at levels below -92 dBm
Overload Protection Uplink: Fully adaptive
Downlink: Fully adaptive
Max. Input Level
(receive isotropic power)
Uplink: -10 dBm
Downlink: -44 dBm
Maximum Output RF Levels (radiated) Uplink: +30 dBm EIRP maximum (composite)
Downlink: +7 dBm max (composite), 0 dBm (per channel) man-
aged per channel
Third Order Intercept (radiated) Uplink: +52 dBm EIRP
Downlink: +30 dBm EIRP
Power Supply Universal power adapter with 6 ft AC cable and 20 ft DC cable.
AC Input: (120-240V)
DC Output: +7.5 VDC and +10.25 VDC that connects to the
indoor unit. Outdoor unit power is supplied via the RF cable.
Power Consumption < 28 W
DONOR UNIT COVERAGE UNIT
Operating
Temperature
-40
°
to 130 F
°
(-40
°
to +55
°
C)
32
°
to +104
°
F
(0
°
to +40
°
C)
Size 14 x 11 x 4 in.
(35 x 28 x 10 cm)
7.5 x 5.5 x 2.5 in.
(19 x 14 x 6 cm)
Weight 4 lb. (2 kg) 2 lb. (1 kg)
RF Connectors CU Port: Type F weatherproof DU Port: Type F
Coverage Extension Port: MCX
RF Cable Standard: RG6 Quad shielded 82 ft (25 m)
Alternate: RG11 Quad shielded 164 ft. (50 m)
Other: RG6 and RG11 Plenum rated