User's Manual

38 SpotCell 163
3.3 Architecture
3.3.1 Physical
Frequency Bands Uplink: 806-821 MHz
Downlink: 851-866 MHz
Formats Supported iDEN
Coverage Area Fully adaptive, supports multiple simultaneous users
Up to 25,000 ft
2
(2300 m
2
)
System Gain Uplink: 0 to 90 dB (under control of adaptive algorithm)
Downlink: 0 to 90 dB (under control of adaptive algorithm)
Downlink Operating Range -95 to -25 dBm (receive isotropic power).
Overload Protection Uplink: Fully adaptive
Downlink: Fully adaptive
Typical 20 dB BW Uplink: 18.3 MHz
Downlink: 18.0 MHz
Max. Output RF Levels (radiated) Uplink: 40 dBm EIRP maximum (composite)
Downlink: 14 dBm max (composite), -6 dBm (per channel) man-
aged per channel
Third Order Intercept (radiated) Uplink: 60 dBm EIRP
Downlink: 33 dBm EIRP
Power Supply Universal power adapter (6-ft AC cable and 20-ft DC cable)
AC Input: (120-240V)
DC Output: +3.8 VDC, +5.8 VDC and +27 VDC that connects to
the CU, DU power is supplied via the RF cable.
Power Consumption < 35 W
DONOR UNIT COVERAGE UNIT
Operating
Temperature
-40
°
to 130 F
°
(-40
°
to +55
°
C)
32
°
to +104
°
F
(0
°
to +40
°
C)
Size 14 x 11 x 4 in.
(35 x 28 x 10 cm)
7.5 x 5.5 x 2.5 in.
(19 x 14 x 6 cm)
Weight 6 lb. (3 kg) 2 lb. (1 kg)
RF Connectors CU Port: Type F weatherproof DU Port: Type F;Coverage Extension Port: MCX
RF Cable Standard: RG6 Quad shielded 82 ft (25 m)
Alternate: RG11 Quad shielded 164 ft. (50 m)
Other: RG6 and RG11 Plenum rated