MOUNTING THE DU
10 SpotCell
3.3 DU outdoor mounting
3.3.1 Mounting to a wood structure
1. Use the holes in mounting bracket as a template and mark the hole
locations. Mark two regular holes if no motion is required or the
hole and the slot if motion is required.
2. Drill two.125" diameter holes approximately. 2.5" deep.
3. Install the DU using the two 1/4" lag bolts.
3.3.2 Mounting to a brick or concrete structure:
1. Use the holes in mounting bracket as a template and mark the hole
locations. Mark the two regular holes if no motion is required or the
hole and the slot if motion is required.
2. Use a masonry drill bit to drill two 5/16"diameter holes, 2 inches
deep.
3. Insert masonry screw anchors so that the anchor is flush to
mounting surface.
4. Install the DU using the two 1/4" lag bolts.
3.3.3 Mounting to a pipe or tubing:
Use the two stainless steel hose clamps supplied in the mounting kit for
the following procedure.
1. Feed the end of the hose clamp through the holes as shown
in Figure 3.4:“Pipe mounted DU”.
2. Rotate the unit to point the unit to the signal source and tighten
clamps.
Note: DO NOT use cable ties to mount the DU.