MOUNTING THE DU
12 SpotCell
To attach the cable to an existing pipe or cable run:
Use tie-wraps to attach the cable to an existing pipe or cable run.
To attach the cable to wood or siding:
Secure the cable to the wall using a cable loop strap as shown below.
Mount the loop strap directly to the wall where possible using a #6 x
1.5” wood screw.
Figure 3.7: Cable strap
To attach the cable to a brick or concrete wall:
1. Drill a 3/16 diameter x 1 1/4 inch deep hole using a masonry drill
bit.
2. Insert the anchor flush with the mounting surface.
3. Use cable clamps and screws to attach cable to the wall.
3.3.5 Bringing the cable indoors
To bring the cable indoors, it may be necessary to drill a hole through
the wall.
To bring the cable through an exterior wall:
1. Depending on the material the wall is made of use a wood or
masonry drill bit to drill a 5/8 inch diameter hole.
2. Pass the connector and cable through the wall.
3. Use the putty/sealant provided to fill the hole.
3.3.6 Grounding:
Ensure there is a connection to earth ground. Use an appropriate
conductor connected from the stud on the DU to earth ground.