SPOTCELL 111S/112S SYSTEM SPECIFICATIONS
Spotwave Wireless Inc. 47
D.4 Architecture
Frequency Band
Passband Bandwidth
Full A, D, B, E, F, C band and sub-band (C1, C2, C3, C4,
C5) selectivity
5, 7.5, 10, 15, 20 MHz
*Start/stop receive band frequency must be specified at time of order.
Formats Supported SC111S support split band PCS & GSM
SC112S supports split band PCS & CDMA
Coverage Area Fully adaptive, supports multiple simultaneous users
Up to 25,000 Sq feet (50,000 sq.ft. in open areas)
System Gain Uplink Automatic, fully adaptive, Maximum 81 dB (including
antennas)
System Gain Downlink Automatic, fully adaptive, maximum 92dB (including
antennas)
Downlink Operating
Range
-100 to –44 dBm (Rx Isotropic Power)
Input Overload Protection Uplink: Fully adaptive
Downlink: Fully adaptive
Maximum Output Levels
(radiated)
Uplink: Fully adaptive, up to +27 dBm EIRP (Composite)
Downlink: Fully adaptive up to +7 dBm EIRP (Composite)
Rated downlink output per carrier is 0dBm for a maximum
of five carriers. If number of carriers exceeds five, per carrier
power is reduced such that the composite downlink power
never exceeds +7dBm EIRP for a nominal antenna gain of
0dBi
Third Order Intercept
(radiated)
Uplink: +50 dBm EIRP
Downlink: +30 dBm EIRP
Power Supply 10.5 VDC universal power adapter that connects to the
Indoor Unit; Donor Unit power is supplied via the RF cable
Power Consumption < 44 W