MOUNTING THE DU AND CU
SpotCell
®
2500Xe 27
Figure 3.8: CU mounted with cover
4.
Secure the cables to the wall using tie wraps and mount directly to the wall where
possible (using 1/2 inch pan head screws). If an anchor is required drill a 3/16 inch
diameter hole, insert the anchor, and fasten with 1/2 inch screws.
3.3 Using the Hidden Cable kit
The Hidden Cable kit includes a BIAS-T (power inserter) and two F-90 connectors that
make it easier to hide the power and RF cables that are normally connected directly to
the CU.
3.3.1 BIAS-T (power inserter)
The BIAS-T (power inserter) is used to discreetly power the system or power the system
from a more conveniently located AC outlet.
To install the BIAS-T
1. Choose an indoor location along the coaxial cable run to install the BIAS-T. The
BIAS-T location must be within 20 feet (6 meters) of an AC outlet so that the power
adapter cord can reach.