Unit does not prime
Volute drain tap open.
Air leak in priming system.
Air leak in suction hoses or fittings
Blockage in suction hoses or strainer.
Non return valve not sealing.
Internal damage to pipe from solenoid
valve to vacuum pump.
Solenoid valve not operating.
Solenoid valve blocked.
Priming tank air filter blocked.
Priming tank knitmesh blocked.
Vacuum pump belts loose or broken.
Vacuum pump electric clutch not
engaged.
Vacuum pump failure.
Suction head too great.
Unit does not pump
Blockage in delivery hoses.
Blockage in impeller.
Excessive impeller clearances.
Broken Impeller.
Pump drive coupling disengaged.
Delivery head too great.