UNISTREAM RANGE CENTRIFUGAL PUMP OPERATORS INSTRUCTIONS Unistream Pumps SPP Pumps Limited Crucible Close Mushet Industrial Park Coleford Gloucestershire GL16 8PS Telephone: + 44 (0)1594 832 701 Fax: + 44 (0)1594 836 300 Document No: W21-002E Revision No: 10 Revision Note No: Windchill Date Issued: August 2012 Produced at SPP Pumps Limited Coleford England
DECLARATION OF CONFORMITY We SPP Pumps Limited Of Crucible Close Mushet Industrial Park Coleford Gloucestershire GL16 8PS Declare that: CENTRIFUGAL PUMP UNISTREAM RANGE As shown on the Pump Nameplate Equipment: Model/Type: Serial Number: For pumps and pumpsets: in accordance with the following Directives: 2006/42/EC 2006/95/EC The Machinery Directive and its amending directives Low Voltage Directive have been designed and manufactured to the following specifications: EN 809:1998+A1:2009 EN 12100
Operators Instructions for Unistream Centrifugal Pumps CONTENTS Section ........................................................ Page 1 General Information & Safety Instructions ............................................ 3 2 Transport Handling and Storage ........... 4 3 General Description ............................... 5 4 Assembly and Installation ...................... 5 5 Commissioning and Operation .............. 7 6 Maintenance and Service ...................... 9 7 Faults and Remedial Action ...
Manual No/Rev W21-002E / 10 1.7 1.8 1.9 Operators Instructions for Unistream Centrifugal Pumps Note any limits to the pump application specified in the contract documentation. Operation of the equipment outside these limits will increase the risk from hazards noted below and may lead to premature and hazardous pump failure. Pumps supplied on pallets may be lifted by forklift truck, to lift from the pallet the pump should be slung as shown. Clear and easy access to all controls, gauges and dials etc.
Operators Instructions for Unistream Centrifugal Pumps parts for storage with the pump. The pump shaft should be rotated by hand at least five turns every six weeks. For special protection of the coupling and electric motor, where applicable, refer to the manufacturers' instructions in the relevant appendix. 2.3.3 Exposed or Extreme Conditions Storage For exposed storage or extreme atmospheric or environmental please refer to SPP Pumps Ltd. storage instructions to suit the applicable.
Manual No/Rev W21-002E / 10 Operators Instructions for Unistream Centrifugal Pumps 4.3 Pump Preparation Abrasion and Entrapment Hazard Do NOT touch any moving or rotating parts. Guards are provided to prevent access to these parts, where they have been removed for maintenance they MUST be replaced before operating the equipment. Remove packaging but leave the flange covers in place, check that impeller rotates freely by hand by turning the shaft. 4.
Operators Instructions for Unistream Centrifugal Pumps Unacceptable Suction Pipework Manual No/Rev W21-002E / 10 Preferred Pipework Discharge Pipe Trapped Air Discharge Valve Check Valve Increaser Suction Valve Eccentric Reducer Unsupported Pipe UNISUC02.CDR Where pumping water at temperatures above 70°C, care must be taken to ensure that enough pressure is available at the impeller entry to prevent vaporisation.
Manual No/Rev W21-002E / 10 Operators Instructions for Unistream Centrifugal Pumps If the stuffing box is supplied with cooling water or the mechanical seal is supplied with clean water flush, check that the water supply is turned on. Failure to supply the stuffing box or mechanical seal with cooling or flush water may result in damage and premature failure of the pump. ATTENTION Check that the rotating assembly is free to rotate by hand before connecting the power supply.
Operators Instructions for Unistream Centrifugal Pumps signal can still be heard with ear defenders worn. Hazardous Gases, Mists, Sprays and Leaks Be aware of the hazards relating to the pumped fluid, especially the danger from inhalation of noxious and toxic gases, skin and eye contact or penetration. Obtain and understand the hazardous substance (COSHH) data sheets relating to the pumped fluid and note the recommended emergency and first aid procedures.
Manual No/Rev W21-002E / 10 Operators Instructions for Unistream Centrifugal Pumps drained down. Hazardous Materials Wear a suitable mask or respirator when working with Packing and Gasket components that contain fibrous material, as these can be hazardous when the fibrous dust is inhaled. Be cautious, if other supplier's components have been substituted for genuine SPP Pumps Ltd parts, these may then contain hazardous materials.
Operators Instructions for Unistream Centrifugal Pumps and without Lantern Ring 6 6 6 If the packing rings are to be cut from a coil, or length of packing, the size, number of rings and length are shown in the tables. Wrap the packing strip around a dummy shaft of the required diameter, overlapping the coils as shown. Cut diagonally at 45° to produce rings with an overlapped split joint. Note that if packing is cut from flat material or with square joint lines, a good seal will not be achieved.
Manual No/Rev W21-002E / 10 Operators Instructions for Unistream Centrifugal Pumps mechanical seal (43.3), from the bearing housing (33.0). Care must be taken to ensure that the stationery element of the seal and the shaft are not damaged when extracting the shaft. Undo the impeller nut (92.2) in a counter clockwise direction and withdraw the impeller (23.0) from the shaft (21.1).
Operators Instructions for Unistream Centrifugal Pumps Dia. 1 = Outside Dia. of Impeller Dia. 2 = Inside Dia. of Impeller Pump Size: Tolerances Dia. 1 Dia. 2 Dia. 1 Dia. 2 -0.1 F8 -0.1 F8 32/13 32/16 69.7 70 - - 79.7 80 - - 94.7 95 - - 114.7 115 - - 65/32 129.6 130 124.6 80/16 80/20 80/26 129.6 130 - 80/32 139.6 140 134.6 100/20 100/26 159.6 160 - 100/32 159.6 160 154.6 155 100/40 159.6 160 159.6 160 125/26 179.6 180 - 125/32 125/40 179.6 180 179.
Operators Instructions for Unistream Centrifugal Pumps Manual No/Rev W21-002E / 10 7. Faults and Remedial Action POTENTIAL FAULT OR DEFECT: No liquid delivered. Insufficient liquid delivered. Liquid delivered at low pressure. Loss of liquid after starting. Excessive vibration. Motor runs hotter than normal. Excessive noise from pump cavitation. Pump bearings run hotter than normal. PROBABLE CAUSES Pump not primed. Speed too low. Speed too high.
Operators Instructions for Unistream Centrifugal Pumps Manual No/Rev W21-002E / 10 CAUSE REMEDIAL ACTION CAUSE REMEDIAL ACTION Pump not primed. Fill pump and suction pipe completely with fluid. Speed too low. Check that the motor is correctly connected and receiving the full supply voltage also confirm that the supply frequency is correct. Excessive wear ring clearance. Replace the wear rings and/or the impeller when the clearance exceeds the maximum adjustment. Damaged impeller.
Operators Instructions for Unistream Centrifugal Pumps Manual No/Rev W21-002E / 10 8. Pump Details 8.1 Pump Dimensions For installation dimensions and pump weights, please refer to a Pump General Arrangement drawing or to pump information from the SPP RAPID electronic catalogue. 8.2 Pump Cross Section Drawings Pump section for shaft units 25 with clamped casing cover. (i.e. pump sizes - 32/13, 32/16, 40/13, 40/16, 50/13, 50/16, 65/13, 65/16, 80/16, 80/20 & 100/20) 41.17 91.
Operators Instructions for Unistream Centrifugal Pumps Manual No/Rev W21-002E / 10 Pump section for shaft units 25 & 35 with bolted casing cover. (i.e. pump sizes - 32/20, 32/26, 40/20, 40/26, 50/20, 50/26, 65/20, 65/26, 80/26, 100/26 &125/26) SOFT PACKED PUMP SECTION 41.17 91.3 16.1 92.0 90.2 45.2 91.4 50.7 33.0 40.02 41.14 90.34 90.1 10.2 36.0 93.0 92.2 21.1 41.15 90.35 94.0 94.01 42.1 32.1 23.0 90.11 93.01 50.2 56.0 90.3 41.1 18.3 52.4 40.01 45.8 40.0 90.22 46.1 90.21 90.31 92.02 92.
Operators Instructions for Unistream Centrifugal Pumps Manual No/Rev W21-002E / 10 Pump section for shaft unit 35 with back case wear rings. (i.e. pump sizes - 65/32, 80/32 & 100/32) SOFT PACKED PUMP SECTION 41.17 91.3 92.0 90.2 50.21 16.1 56.0 45.2 50.7 33.0 91.4 40.02 41.14 90.34 90.1 10.2 36.0 21.1 93.0 92.2 94.0 41.15 90.35 42.1 94.01 32.1 23.0 90.11 93.01 50.2 56.0 90.3 41.1 18.3 52.4 40.01 40.0 45.8 90.22 46.1 90.21 90.31 64.2 92.02 92.01 41.
Operators Instructions for Unistream Centrifugal Pumps Manual No/Rev W21-002E / 10 Pump section for shaft unit 45. (i.e. pump sizes - 100/40, 125/32, 125/40, 150/32, & 150/40) SOFT PACKED PUMP SECTION 41.17 91.3 50.21 92.0 45.2 90.2 16.1 56.0 50.7 91.4 33.0 41.14 90.34 40.02 10.2 90.1 93.0 92.2 36.0 41.15 90.35 21.1 94.01 94.0 42.1 23.0 32.1 50.2 56.0 90.3 41.1 90.11 93.01 18.3 52.4 40.01 40.0 45.8 90.22 46.1 90.21 90.31 64.2 92.02 92.01 41.
Operators Instructions for Unistream Centrifugal Pumps Manual No/Rev W21-002E / 10 Parts Identification List - (Numbers as shown on cross section drawings) Part No. Description: 10.2 16.0 16.1 16.5 18.3 21.1 23.0 32.1 33.0 36.0 40.0 40.01 40.02 40.03 41.1 41.11 41.14 41.15 41.16 41.17 41.22 41.23 42.1 43.3 45.2 45.8 46.1 50.2 50.21 50.7 52.3 Part No.
Operators Instructions for Unistream Centrifugal Pumps Manual No/Rev W21-002E / 10 Spares Kits for Unistream Pumps Spares Kit Application Comprising Parts (see Parts List) Gasket Set 40.0, 40.01, 40.02 & 93.0 Packed Gland Replacement 46.1, 52.4, 93.0 & 40.01 Mechanical Seal Replacement 43.3, 52.3, 93.0, 40.01 & 43.03 Shaft Replacement 21.1, 50.7, 94.0, 94.01, 92.2 & 93.0 Bearing Replacement 40.02, 42.1 & 32.1 Impeller Replacement 23.0, 50.2, 50.21, 56.0, 93.0 & 94.
Operators Instructions for Unistream Centrifugal Pumps Manual No/Rev W21-002E / 10 9. Additional Information 9.1 Exploded Pump Diagram Showing Typical Soft Packed Pump (for information only) 90.3 41.1 10.2 41.17 91.3 90.2 92.2 93.0 50.2 23.0 40.0 16.1 92.02 92.0 56.0 45.8 46.1 52.4 40.01 50.7 90.1 36.0 40.02 42.1 32.1 94.01 21.1 33.0 91.4 94.0 92.01 36.0 42.1 45.2 92.02 64.2 90.13 40.02 36.0 90.1 41.11 UNIEXP02.WMF 18.3 93.01 90.
Operators Instructions for Unistream Centrifugal Pumps Manual No/Rev W21-002E / 10 10. Standard Metric Nut and Bolt Torque Recommendations This information is for reference only. The user must check that the torque figures listed here are applicable to the fasteners used. Nuts and bolts should be neither under nor over tightened. Grade of Bolt Approximate Torque (Nm) for Bolt Diameters: M5 M6 M8 M10 M12 M16 M20 M24 M30 M36 4.6 2.7 4.5 11 22 38 95 185 320 633 1110 8.8 6.9 11.
Operators Instructions for Unistream Centrifugal Pumps Manual No/Rev W21-002E / 10 11. SPARES & SERVICE SPP Pumps operate a comprehensive Spares and Service support network throughout the world, and can be contacted as follows: SPARES & SERVICE Telephone: For spare parts, supply only. ask for - +44 (0)118 932 3123 For breakdowns, spare parts and on-site fitting, pump installation and commissioning, and service contracts. ask for For breakdowns outside office hours.