SDS

Material Safety Data Sheet
1. PRODUCT IDENTIFICATION
Product Name:
Spray Nine
®
Product Type: Multi-Purpose Germicidal Cleaner
Product Trade Name: 26832
2. COMPOSITION/INFORMATION ON INGREDIENTS
Component Weight% ACGIH; TLV-TWA OSHA PEL
2-BUTOXYETHANOL
111-76-2
1-5 20 ppm 50 ppm; 240 mg/m
3
ETHOXYLATED C9-C11
ALCOHOLS
68439-46-3
1-5 NA NA
3. HAZARDS IDENTIFICATION
Effects of Acute Exposure:
Product may cause reversible eye and skin irritation.
May irritate respiratory system upon frequent or prolonged use
Primary Routes of Entry:
Eye and skin contact, inhalation
Signs and Symptoms of
Exposure:
Overexposure may cause eye and skin redness May cause inflammation of mucous membranes and
irritation Ingestion may cause nausea and vomiting
Medical Conditions Recognized as
Being Aggravated by Exposure:
None known. Preexisting eye, skin and respiratory disorders may be aggravated by overexposure to this
product.
Chronic Health Hazard
None known
4. FIRST AID MEASURES
Eye Contact:
Immediately flush with plenty of water. After initial flushing, remove any contact lenses and continue
flushing for at least 15 minutes. Contact a physician if irritation persists.
Skin Contact:
Immediately remove contaminated clothing and excess contaminant. Flush with water for at least 15
minutes. Wash thoroughly with soap and water. Consult a physician if irritation develops
Ingestion:
If swallowed, DO NOT induce vomiting. Give victim water, call a physician immediately. Never give
anything by mouth to an unconscious person
Inhalation:
Move to fresh air; get medical attention if symptoms persist
Notes to Physician:
Treat symptomatically
5. FIRE FIGHTING MEASURES
Flash Point °F(C°):
182°F/83°C TCC
Recommended Extinguishing Media:
Carbon dioxide, Dry chemical, Foam
Special Fire-Fighting Procedures:
Wear suitable protective equipment. Use water spray to cool exposed
containers.
Hazardous Products of Combustion:
Oxides of carbon, Oxides of nitrogen
Unusual Fire/Explosion Hazards:
Does not sustain combustion (ASTM D4206).
Sensitivity to Static Discharge:
Sensitivity to static discharge is not expected
Mechanical Sensitivity:
None reasonably foreseeable
1 of 3
Canadian Corporate Office:
ITW Permatex Canada
8450 Lawson Road, Unit 1
Milton, ON L9T 0J8
Toll Free: (800) 924-6994
(905) 693-8900
Emergency: ChemTel (800) 255-3924
Permatex, Inc.
10 Columbus Blvd.
Hartford, CT 06106 USA
Telephone: 1-87-Permatex
(877) 376-2839
Emergency: 800-255-3924
International Emergency: +01-813-248-0585
UPC 077174001201

Summary of content (3 pages)