MSDS

Flammable properties
Vapor or gas may spread to distant ignition sources and flash back. Runoff to sewer may
cause fire or explosion hazard.
.
5. Fire Fighting Measures
s
p
ace
Suitable extinguishing media
Large Fires: Water spray, fog or regular foam.
Small Fires:
Extinguishing media
s
p
ace
Protective equipment and
precautions for firefighters
In case of fire and/or explosion do not breathe fumes. Containers should be cooled with
water to prevent vapor pressure build up.
Protection of firefighters
s
p
ace
Methods for containment
Stop leak if you can do so without risk. Move the cylinder to a safe and open area if the
leak is irreparable. Stop the flow of material, if this is without risk.
.
6. Accidental Release Measures
s
p
ace
Methods for cleaning up
Use a non-combustible material like vermiculite, sand or earth to soak up the product
and place into a container for later disposal.
Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface
thoroughly to remove residual contamination.
s
p
ace
Handling
Pressurized container: Do not pierce or burn, even after use. Do not smoke while using
or until sprayed surface is thoroughly dry. Do not use if spray button is missing or
defective. Do not re-use empty containers. Avoid contact with skin. Avoid contact with
eyes. Avoid prolonged exposure.
.
7. Handling and Storage
s
p
ace
Storage
Contents under pressure. Do not puncture, incinerate or crush. The pressure in sealed
containers can increase under the influence of heat. Keep away from heat and flame.
Avoid exposure to long periods of sunlight. Store in cool place. Keep container dry. Keep
out of the reach of children. Keep away from food, drink and animal feedingstuffs. Level 1
Aerosol (NFPA 30B)
s
p
ace
Exposure limits
ACGIH
Components
CAS #
Propane 74-98-6
TWA
1000 ppm
STEL
Not established
Ceiling
Not established
space
n-Butane 106-97-8 1000 ppm Not established Not established
.
8. Exposure Controls / Personal Protection
s
p
ace
OSHA
Components
space
CAS #
Propane 74-98-6
TWA
1000 ppm
STEL
Not established
Ceiling
Not established
s
p
ace
Eye / face protection
Chemical goggles are recommended.
Personal protective equipment
s
p
ace
Skin protection
Wear appropriate chemical resistant clothing. Chemical resistant gloves. Not normally
needed.
s
p
ace
Respiratory protection
When workers are facing concentrations above the exposure limit they must use
appropriate certified respirators. If permissible levels are exceeded use NIOSH
mechanical filter / organic vapor cartridge or an air-supplied respirator.
s
p
ace
Appearance
Compressed liquefied gas.
.
9. Physical & Chemical Properties
s
p
ace
Boiling point
206.6 °F (97.2 °C) estimated
s
p
ace
Color
White.
s
p
ace
Density
0.8628 g/cm3 estimated
s
p
ace
Flammability (HOC)
13.2705 kJ/g estimated
s
p
ace
Flash back
No
s
p
ace
Product name: Don't Let the Bed Bugs Bite! Good Night
Product #: 003-003 Revision date: 03-NOV-2010 Print date: 03-NOV-2010
MSDS US
2 / 5
Good Night Bed Bug Killer
UPC 041911000338