SDS
Version: 2.1
Revision Date: 09/15/2020
SDS_US - RE1000000075
3/11
Special protective equipment and precautions for firefighters
Special fire fighting
procedures:
No data available.
Special protective equipment
for fire-fighters:
Firefighters must use standard protective equipment including flame
retardant coat, helmet with face shield, gloves, rubber boots, and in
enclosed spaces, SCBA.
6. Accidental release measures
Personal precautions,
protective equipment and
emergency procedures:
No data available.
Methods and material for
containment and cleaning
up:
Stop the flow of material, if this is without risk. Absorb with sand or other
inert absorbent.
Environmental Precautions:
Avoid release to the environment. Prevent further leakage or spillage if safe
to do so. Do not contaminate water sources or sewer. Environmental
manager must be informed of all major spillages.
7. Handling and storage
Handling
Technical measures (e.g. Local
and general ventilation):
No data available.
Safe handling advice:
Provide adequate ventilation. Wear appropriate personal protective
equipment. Observe good industrial hygiene practices.
Contact avoidance measures:
No data available.
Storage
Safe storage conditions:
Protect from sunlight. Store in a cool place.Aerosol Level 1
Safe packaging materials:
No data available.
Storage Temperature:
No data available.
8. Exposure controls/personal protection
Control Parameters
Occupational Exposure Limits
Chemical Identity
Type
Exposure Limit Values
Source
Ethanol
REL
1,000 ppm
1,900 mg/m3
US. NIOSH: Pocket Guide to Chemical Hazards, as
amended
PEL
1,000 ppm
1,900 mg/m3
US. OSHA Table Z-1 Limits for Air Contaminants (29
CFR 1910.1000), as amended
TWA
1,000 ppm
1,900 mg/m3
US. OSHA Table Z-1-A (29 CFR 1910.1000), as
amended
STEL
1,000 ppm
US. ACGIH Threshold Limit Values, as amended
Ethanol, 2-butoxy-
TWA
20 ppm
US. ACGIH Threshold Limit Values, as amended
REL
5 ppm
24 mg/m3
US. NIOSH: Pocket Guide to Chemical Hazards, as
amended
PEL
50 ppm
240 mg/m3
US. OSHA Table Z-1 Limits for Air Contaminants (29
CFR 1910.1000), as amended
TWA
25 ppm
120 mg/m3
US. OSHA Table Z-1-A (29 CFR 1910.1000), as
amended