RL Series Installation Instructions IN022 Rev M 0321 3 Saber Way, Ward Hill, MA 01835 | spruce.
Fan Installation & Operating Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE TO FAN IS LOCKED IN "OFF" POSITION. DISCONNECT POWER BEFORE SERVICING FAN. 1. WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
1. WARNING – TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. 2. WARNING – TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boil over’s cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé’). c) Clean ventilating fans frequently.
2.0 Fan Sealing RL Series fans are factory sealed, no additional caulk or other materials are required to inhibit air leakage. 3.0 Ducting Use only metal ducting for fans used in kitchen areas or as range hood or remote blowers. Any type of ducting is acceptable for areas other than kitchens, however, flexible nonmetallic ducting is recommended for easy installation and quieter operation.
Step 4: Connect inlet grille(s). An optional back draft damper may be installed in the inlet grille to prevent cold air from backing into the inlet, prevent conditioned air from escaping and also prevent condensation from forming inside the ductwork. Back draft dampers are highly recommended at each intake grille for bathroom ventilation in all cold climate installations. Step 5: Connect outlet of fan to outside vent. The outside vent may go through the roof, sidewall or soffit as desired.
RL SERIES PRODUCT SPECIFICATIONS The following chart shows fan performance for the RL Series Commercial/Residential Fan: Typical CFM vs. Static Pressure Model Max Static "WC 0" 0.2" 0.5" 0.75" 1.0" 1.25" 1.5" RL200 163 150 123 101 76 54 28 1.78" WC RL300 268 240 194 156 117 74 34 1.84" WC RL350 300 280 238 201 164 127 89 2.11" WC RL450 507 460 371 298 241 193 144 2.27" WC RL500 545 500 419 349 275 222 170 2.
IN022 Rev M 0321 3 Saber Way, Ward Hill, MA 01835 | spruce.
IMPORTANT INSTRUCTIONS TO INSTALLER Inspect the RL Series Fan for shipping damage within 15 days of receipt. Notify Spruce of any damages immediately. Spruce is not responsible for damages incurred during shipping. However, for your benefit, Spruce does insure shipments. There are no user serviceable parts inside the fan. Do not attempt to open. Return unit to factory for service. Install the RL Series Fan in accordance with all state and local building codes and state regulations.