Technical Specifications

Page 5 of 7 IN009 Rev L
The following chart shows fan performance for the RV Series Commercial/Residential Fan:
Typical CFM Vs Static Suction " WC Max Static
0" .2" .5" .75" 1.0" 1.5" 2.0" 2.5" Pressure
RV100 113 100 71 50 18 - - - 1.06”WC
RV125 116 110 98 88 72 44 4 - 2.08”WC
RV150 150 140 119 100 76 26 - - 1.77”WC
RV200 185 170 144 123 87 1 - - 1.51”WC
Power Consumption @ 120 VAC , 60Hz (1.4 Amp Maximum)
RV100 35 - 44 watts
RV125 48 - 68 watts
RV150 48 - 65 watts
RV200 49 - 65 watts
Size:
Weight: 6 lbs.
Mounting: Mounting bracket included.
Recommended ducting: 4”, 5” or 6” Flexible Ducting.
Storage temperature range: 32 - 100 degrees F.
Normal operating temperature range: -20 - 120 degrees F.
Maximum inlet air temperature: 90 degrees F continuous.
Class B Insulation
Continuous Duty
3000 RPM
Thermally protected
Rated for Indoor or Outdoor use
Rated for Residential and Commercial use
Fan Model
“A” Dim
Duct Size
RV100
3.9”
4”
RV125
3.9”
4”
RV150
3.9”
4”
RV200
5.9”
6”

Summary of content (2 pages)